SMC - Vacuum Ejectors (Vacuum Generators) / Vacuum Pump Systems
SMC – Vacuum Ejectors (Vacuum Generators) / Vacuum Pump Systems มีทั้งหมด 9 รุ่น แต่ละรุ่นมีขนาด, คุณสมบัติ และการใช้งานที่แตกต่างกันออกไป
1. Vacuum Unit (Vacuum Generators) ZK2□A
Features | Vacuum Unit (Vacuum Generators) ZK2□A
-
- Compatible with ejector systems and vacuum pump systems
- Energy saving ejector Air supply is cut-off when vacuum is reached. Air consumption: 93% reduction (Under SMC’s measurement conditions)
- More efficient ejector: Suction flow increased by 50% (Compared to other SMC 1-stage ejectors)
- Energy saving efficiency: 93% reduction
- Improved low noise and suction flow by adoption of a high-noise reduction silencer
Specifications | Vacuum Unit (Vacuum Generators) ZK2□A
Ejector series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
Guidelines for applicable pad (mm) |
Vacuum pump system series |
---|---|---|---|---|---|
ZK2□07 | 0.7 | 29 | 24 | 2 to 40 | ZK2□00 |
ZK2□10 | 1.0 | 44 | 40 | 2 to 50 | ZK2□00 |
ZK2□12 | 1.2 | 61 | 58 | 2 to 125 | ZK2□00 |
ZK2□15 | 1.5 | 67 | 90 | 2 to 150 | ZK2□00 |
2. Vacuum Manifold for Fieldbus System ZKJ
SMC – Vacuum Manifold for Fieldbus System ZKJ
Features | Vacuum Manifold for Fieldbus System ZKJ
- Fieldbus-compatible
- Requires no input/output unit. Space saving
- Reduced wiring time
- Compatible protocol: PROFINET
- Energy saving ejector: Air consumption reduced by 90%
- Supply valve: N.O. specification
- Can hold vacuum even when the power goes out or is turned off
(Supposing the supply pressure is being maintained) - Prevents the sudden dropping of workpieces
(Supposing the supply pressure is being maintained)
- Can hold vacuum even when the power goes out or is turned off
- IP65: Dust-tight/Water-jet-proof
Specifications | Vacuum Manifold for Fieldbus System ZKJ
Ejector series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
---|---|---|---|
ZKJ07 | 0.7 | 31 | 26 |
ZKJ10 | 1.0 | 53 | 48 |
ZKJ12 | 1.2 | 63 | 68 |
ZKJ15 | 1.5 | 74 | 102 |
3. Space Saving Vacuum Ejector (Vacuum Generators) / Pump System ZQ
SMC – Space Saving Vacuum Ejector (Vacuum Generators) / Pump System ZQ
Features | Space Saving Vacuum Ejector (Vacuum Generators) / Pump System ZQ
- Compatible with ejector systems and vacuum pump systems
- Width: 10 mm, Weight: 109 g (Single unit, with vacuum pressure switch and suction filter)
- Digital vacuum pressure switch
- With LED display function
- Adaptable to manifold applications
Specifications | Space Saving Vacuum Ejector (Vacuum Generators) / Pump System ZQ
Ejector series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
Guidelines for applicable pad (mm) |
Vacuum pump system series |
---|---|---|---|---|---|
ZQ105 | 0.5 | 5 | 14 | 2 to 13 | ZQ1000 |
ZQ107 | 0.7 | 10 | 23 | 2 to 20 | ZQ1000 |
ZQ110 | 1.0 | 22 | 46 | 2 to 32 | ZQ1000 |
4. Large Size Vacuum Module (Vacuum Generators) ZR
SMC – Large Size Vacuum Module (Vacuum Generators) ZR
Features | Large Size Vacuum Module (Vacuum Generators) ZR
- Compatible with ejector systems and vacuum pump systems
- Necessary functions can be combined through a modular design.
- Double solenoids provide a self-holding function.
- Adaptable to manifold applications
- Functions such as a digital vacuum switch or a solenoid valve can be selected.
Specifications | Large Size Vacuum Module (Vacuum Generators) ZR
Series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
Guidelines for applicable pad (mm) |
Vacuum pump system series |
---|---|---|---|---|---|
ZR110 | 1.0 | 25 | 53 | 2 to 32 | ZR100 |
ZR113 | 1.3 | 42 | 86 | 2 to 50 | ZR100 |
ZR115 | 1.5 | 63 | 102 | 2 to 100 | ZR100 |
ZR118 | 1.8 | 74 | 155 | 2 to 125 | ZR100 |
ZR120 | 2.0 | 95 | 194 | 2 to 150 | ZR100 |
5. Compact Vacuum Unit (Vacuum Generators) ZB
SMC – Compact Vacuum Unit (Vacuum Generators) ZB
Features | Compact Vacuum Unit (Vacuum Generators) ZB
- Compatible with ejector systems and vacuum pump systems
- Quick response: Response time of the valve 5 ms, vacuum response time 28 ms
- Energy saving: Air consumption reduced by 17%, Vacuum pressure reached increased by 21%
- Compact/Lightweight: 46 g
- With vacuum pressure switch Can copy to up to 10 switches simultaneously
Specifications | Compact Vacuum Unit (Vacuum Generators) ZB
Ejector series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
Guidelines for applicable pad (mm) |
Vacuum pump system series |
---|---|---|---|---|---|
ZB03 | 0.3 | 2 | 3.5 | 2 to 8 | ZB00 |
ZB04 | 0.4 | 3.5 | 6.5 | 2 to 10 | ZB00 |
ZB05 | 0.5 | 4.5 | 10 | 2 to 13 | ZB00 |
ZB06 | 0.6 | 7 | 18 | 2 to 20 | ZB00 |
6. Compact Vacuum Ejector (Vacuum Generators) ZA
SMC – Compact Vacuum Ejector (Vacuum Generators) ZA
Specifications | Compact Vacuum Ejector (Vacuum Generators) ZA
Series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
Guidelines for applicable pad (mm) |
---|---|---|---|---|
ZA105 | 0.5 | 4 | 12 | 2 to 13 |
ZA107 | 0.7 | 8 | 28 | 2 to 20 |
7. Vacuum Module (Vacuum Generators) ZX
SMC – Vacuum Module (Vacuum Generators) ZX
Specifications | Vacuum Module (Vacuum Generators) ZX
Series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
Guidelines for applicable pad (mm) |
Vacuum pump system series |
---|---|---|---|---|---|
ZX105 | 0.5 | 5 | 13 | 2 to 13 | ZX100 |
ZX107 | 0.7 | 10 | 23 | 2 to 20 | ZX100 |
ZX110 | 1.0 | 22 | 46 | 2 to 25 | ZX100 |
8. Vacuum Ejector (Vacuum Generators) ZM
SMC – Vacuum Ejector (Vacuum Generators) ZM
Specifications | Vacuum Ejector (Vacuum Generators) ZM
Series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
Guidelines for applicable pad (mm) |
---|---|---|---|---|
ZM05 | 0.5 | 15 | 17 | 2 to 16 |
ZM07 | 0.7 | 23 | 33 | 2 to 25 |
ZM10 | 1.0 | 38 | 60 | 2 to 32 |
ZM13 | 1.3 | 44 | 85 | 2 to 40 |
ZM15 | 1.5 | 45 | 110 | 2 to 50 |
9. Multistage Ejector (Vacuum Generators) ZL1 / ZL3 / ZL6
SMC – Multistage Ejector (Vacuum Generators) ZL1 / ZL3 / ZL6
Features | Multistage Ejector (Vacuum Generators) ZL1 / ZL3 / ZL6
- Max. suction flow rate: 3 types available: 100, 300, and 600 L/min (ANR)
- Air consumption: 90% reduction (For the ZL3, ZL6)
- Weight: Max. 60% reduction [ZL112 (Existing model): 450 g R ZL1: 180 g]
- 3-stage diffuser construction (For the ZL1:SMC comparison) Suction flow rate increased by 250%
- 3 types of vacuum pressure sensors
- No tools are required! Maintenance labor can be reduced.
- *1 ZL3H, ZL6H (Standard supply pressure: 0.5 MPa)
- *2 Branch + Port exhaust
Specifications | Multistage Ejector (Vacuum Generators) ZL1 / ZL3 / ZL6
Series | Nozzle diameter (mm) |
Max. suction flow [L/min(ANR)] |
Air consumption [L/min(ANR)] |
---|---|---|---|
ZL1 | 1.2 | 100 | 57 |
ZL3 | 1.9 1.5 |
300∗2 | 135∗1 |
ZL6 | 1.9 x 2 1.5 x 2 |
600∗2 | 270∗1 |