Directional spool valves รุ่น WPH
รายละเอียด Directional spool valves, pilot operated, with pneumatic-hydraulic actuation รุ่น WPH
- Size 10, 16, 25 (4W.H22), 25 (4W.H25), 32
- Component series 4X, 7X, 6X
- Maximum operating pressure 280 bar
- Maximum flow 1100 l/min
Features
- Type of actuation: pneumatic-hydraulic
- For subplate mounting
- Porting pattern according to ISO 4401 and NFPA T3.5.1 R2-2002
- Subplates according to data sheets 45054 to 45060 (separate order)
- Spring centering, spring end position or hydraulic end position
- Optional auxiliary operating device
- Switching time adjustment, optional
- Preload valve in channel P of the main valve, optional
- Stroke setting at main spool, optional
- Stroke setting and/or end position control, optional
- Inductive position switch and proximity sensors (contactless)
Type code
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
WPH | / | 6 | / | * |
01 | up to 280 bar | no code |
02 | 3-way version | 3 |
4-way version | 4 | |
Types of actuation | ||
---|---|---|
03 | pneumatic-hydraulic | WPH |
Size | ||
04 | NG10 | 10 |
NG16 | 16 | |
NG25 (type 4W.H 22 .7X/…) | 22 | |
NG25 (type 4W.H 25 .6X/…) | 25 | |
NG32 | 32 | |
Spool return in the main valve | ||
05 | by means of springs | no code |
Hydraulic 3) | H | |
06 | Spool symbols see symbols | |
Component series | ||
07 | 40 to 49 – NG10 (40 to 49: unchanged installation and connection dimensions) | 4X |
60 to 69 – NG25 (4W.H 25.) and NG32 (60 to 69: unchanged installation and connection dimensions) | 6X | |
70 to 79 – NG16 (from series 72) and NG25 (4W.H 22.) (70 to 79: unchanged installation and connection dimensions) | 7X | |
Spool return in the pilot control valve with 2 spool positions only possible with spools B, C, D and hydraulic control spool return in the main valve: | ||
08 | With spring return | no code |
Without spring return | O | |
Without spring return with detent | OF | |
Pilot control valve | ||
09 | with fluidic actuation (standard valve) | 6 |
10 | Without manual override | no code |
With manual override | N | |
11 | External pilot oil supply, external pilot oil return 1) | no code |
Pilot oil supply internal, pilot oil return external 1; 2) | E | |
Pilot oil supply internal, pilot oil return internal 2) | ET | |
External pilot oil supply, internal pilot oil return 1) | T | |
12 | Without switching time adjustment | no code |
Switching time adjustment as supply control | S | |
Switching time adjustment as discharge control | S2 | |
Spool position monitoring | ||
13 | Without position switch | no code |
Monitored spool position “a” | QMAG24 | |
Monitored spool position “b” | QMBG24 | |
Monitored spool position “a” and “b” | QMABG24 | |
monitored rest position | QM0G24 | |
14 | Stroke setting see stroke setting in type key table | |
Throttle insert | ||
15 | Without throttle insert | no code |
Throttle Ø 0,8 mm | B08 | |
Throttle Ø 1,0 mm | B10 | |
Throttle Ø 1.2 mm | B12 | |
Throttle Ø 1.5 mm | B15 | |
Throttle Ø 2.0 mm | B20 | |
Throttle Ø 2.5 mm | B25 | |
preload valve (not for NG10) 4) | ||
16 | Without preload valve | no code |
With preload valve (pö = 4.5 bar) | P4,5 | |
17 | Without pressure reducing valve | no code |
With pressure reducing valve | D3 4) | |
Seal material | ||
18 | NBR seals | no code |
FKM seals (other seals upon request) | V | |
Observe compatibility of seals with hydraulic fluid used. | ||
19 | Information in the plain text | * |
- External pilot oil supply X or return Y:
- with NG10, version SO30 has to be used if sandwich plates are installed. The identification SO30 has to be used at the end of the type designation (sandwich plate).
- the maximum admissible operating parameters of the pilot control valve must be observed!
- observe the maximum pilot pressure!
- Internal pilot oil supply (version “ET” and “E”):
- minimum pilot pressure: please observe the Technical data!
- to prevent inadmissibly high pressure peaks, a “B10” throttle insert must be provided in port P of the pilot control valve (see Pilot oil supply).
- 2 spool positions (hydraulic end position): only piston C, D, Y, K ,Z
- only in connection with throttle insert “B10”
pSt | Pilot pressure |
ppilot min | Pilot pressure, minimum |
ptank | Tank pressure |
pö | Cracking pressure |
Preferred types and standard units are contained in the EPS (standard price list).
Model | Code |
---|---|
4WPH 10 D4X/6QMBG24 | R900726718 |
4WPH 10 E67-4X/6NETS/B10 | R901431908 |
4WPH 10 J4X/6NTS2 | R900246047 |
4WPH 16 C7X/6NET/B10P4,5/A | R978042885 |
4WPH 16 D7X/6EQMBG24 | R900972453 |
4WPH 16 D7X/6QMBG24 | R900707695 |
4WPH 16 G7X/6 | R900941203 |
4WPH 16 G7X/6/V | R900930266 |
4WPH 16 G7X/6ET/B10 | R900711919 |
4WPH 16 GB7X/6/V | R900937175 |
4WPH 16 H7X/6 | R900947810 |
4WPH 16 HD7X/OF6NET/B08V | R900942567 |
4WPH 16 HD7X/OF6NET/B08V/A | R978901339 |
4WPH 16 J7X/6ETSQMAG24/B10P4,5 | R901214084 |
4WPH 16 K7X/6ET/B30/A | R978906947 |
4WPH 22 C7X/6 | R900571662 |
4WPH 22 C7X/6NE/B10P4,5/5 | R901285789 |
4WPH 22 C7X/6NET/B10P4,5/5 | R901379449 |
4WPH 22 E7X/6S2 | R900587083 |
4WPH 22 G7X/6 | R900911924 |
4WPH 22 G7X/6/B10 | R900359917 |
4WPH 22 H7X/6ET/B10P4,5 | R901311281 |
4WPH 22 H7X/6NETS2/B25P4,5D3/A | R978024206 |
4WPH 22 H7X/6NT/A | R978919052 |
4WPH 22 HC7X/OF6 | R901051667 |
4WPH 22 HD7X/O6N/B12 SO765 | R901096200 |
4WPH 22 J7X/6NET/B10V/5 | R901364224 |
4WPH 22 M7X/6NT/B10D3/5 | R901371610 |
4WPH 32 C6X/6 | R900721564 |
4WPH 32 G6X/6/A | R978005464 |
4WPH 32 G6X/6/A/V | R901194476 |
4WPH 32 HM6X/6N/V/A | R978853626 |
4WPH10J4X/6N/A | R978915599 |