OMRON Fiber Sensor - E3NX-CA series
OMRON Fiber Sensor Amplifier – E3NX-CA series
Model Numbers | Fiber Amplifier Sensor – E3NX-CA series
Fiber Amplifier Units
Type | Appearance | Connecting method | Inputs / outputs | Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Standard models | Pre-wired (2 m) | 1 output | E3NX-CA11 2M | E3NX-CA41 2M | |
Wire-saving Connector | 1 output | E3NX-CA6 | E3NX-CA8 | ||
Advanced models | Pre-wired (2 m) | 2 outputs + 1 input | E3NX-CA21 2M | E3NX-CA51 2M | |
Model for Sensor Communications Unit * | Connector for Sensor Communications Unit | — | E3NX-CA0 |
* A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
Note: Refer to your OMRON website for details on models with wire-saving connectors.
Fiber Units
Sensing method | Appearance | Sensing direction | Size | Model |
---|---|---|---|---|
Reflective | Right-angle | M6 | E32-C91N 2M | |
Through-beam (Grooved type) | Array | 10 mm | E32-G16 2M |
Note: Refer to Fiber Units on your OMRON website or to the Fiber Sensor Best Selection Catalog (Cat. No. E418-E1) for details on Fiber Units.
Accessories (Sold Separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. *Protective stickers are provided.
Type | Appearance | Cable length | No. of conductors | Model | Applicable Fiber Amplifier Units |
---|---|---|---|---|---|
Master Connector | 2 m | 3 | E3X-CN11 | E3NX-CA6 E3NX-CA8 |
|
Slave Connector | 1 | E3X-CN12 |
Note: Models are also available with a 5-m cable. The model names have the suffix 5M. Ask your OMRON representative for delivery times.
Mounting Bracket
A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
E39-L143 | 1 |
DIN Tracks
A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Note: Refer to PFP-[] on your OMRON website for details.
End Plate
Two End Plates are provided with the Sensor Communications Unit. End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required.
Appearance | Type | Model | Quantity |
---|---|---|---|
Shallow type, total length: 1 m | PFP-100N | 1 | |
Shallow type, total length: 0.5 m | PFP-50N | ||
Deep type, total length: 1 m | PFP-100N2 |
Appearance | Model | Quantity |
---|---|---|
PFP-M | 1 |
Note: Refer to PFP-M on your OMRON website for details.
Related Products
Sensor Communications Units
Type | Appearance | Model |
---|---|---|
Sensor Communications Unit for EtherCAT | E3NW-ECT | |
Distributed Sensor Unit | E3NW-DS |
Note: Refer to your OMRON website for details.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Specifications | Fiber Amplifier Sensor – E3NX-CA series
Ratings and Specifications
Type | Standard models | Advanced models | Model for Sensor Communications Unit *1 | ||
---|---|---|---|---|---|
NPN output | E3NX-CA11 | E3NX-CA6 | E3NX-CA21 | E3NX-CA0 | |
PNP output | E3NX-CA41 | E3NX-CA8 | E3NX-CA51 | ||
Connecting method | Pre-wired | Wire-saving Connector |
Pre-wired | Connector for Sensor Communications Unit |
|
I/O | Outputs | 1 output | 2 outputs | — *3 | |
External input | — | 1 input *2 | |||
Light source (wavelength) | White LED (420 to 700 nm) | ||||
Supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the connector through the Sensor Communications Unit. |
|||
Power consumption *4 | At Power Supply Voltage of 24 VDC Normal mode: 960 mW max. (Current consumption: 40 mA max.) Eco function ON: 720 mW max. (Current consumption: 30 mA max.) Eco function LO: 800 mW max. (Current consumption: 33 mA max.) |
||||
Control output | Load power supply voltage: 30 VDC max., open-collector output Load current: Groups of 1 to 3 Amplifiers: 100 mA max., Groups of 4 to 30 Amplifiers: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
— | |||
Indications | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), NO/NC indicator (orange), Smart Tuning indicator (blue), and OUT selection indicator (orange, only on models with 2 outputs) |
||||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection |
Power supply reverse polarity protection |
|||
Sensing method | Contrast Mode: Light intensity discrimination for RGB (initial state/after 2-point tuning) (R+G+B light intensity discrimination for 1-point tuning) Color Mode: RGB ratio discrimination |
||||
Re- sponse time |
Super-high-speed Mode (SHS) *5 |
Operate or reset: 50 μs (only in Contrast Mode) | |||
High-speed Mode (HS) |
Operate or reset: 250 μs | ||||
Standard Mode (Stnd) |
Operate or reset: 1 ms | ||||
Giga-power Mode (GIGA) |
Operate or reset: 16 ms | ||||
Sensitivity adjustment | Smart Tuning (2-point tuning, full autotuning, or 1-point tuning (1% to 99%)) or manual adjustment |
||||
Maximum connectable Units | 30 Units | 30 Units (When connected to OMRON NJ-series Unit) |
|||
No. of Units for mutual interfer- ence pre- vention *6 |
Super-high-speed Mode (SHS) *5 |
— | |||
High-speed Mode (HS) |
10 Units | ||||
Standard Mode (Stnd) |
10 Units | ||||
Giga-power Mode (GIGA) |
10 Units | ||||
Func- tions |
Operation mode | Contrast Mode: NO (Light-ON) or NC (Dark-ON) Color Mode: NO (ON for match: ON for same color as registered color) or NC (ON for mismatch: ON for different color from registered color) |
|||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF- delay timer (Counted by 0.1 s in a range of 0.1 to 0.5 ms, by 0.5 ms for 0.5 to 5 ms, and by 1 ms for 5 to 9999 ms. Default: 10 ms, Error: 0.1 ms) |
||||
Zero reset | Contrast Mode only Negative values can be displayed. (Threshold level is shifted.) |
||||
Resetting settings *7 |
Select from initial reset (factory defaults), user reset (saved settings), or bank reset. | ||||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). |
||||
Bank switching | Select from banks 1 to 8. | ||||
Power tuning level |
Set from 100 to 9,999. (The RGB maximum incident level at Smart Tuning is adjusted to the power tuning level.) |
||||
Output 2 | — | Normal, error output, AND output, or OR output |
— | ||
External input | — | Select from input OFF, tuning, fullauto tuning, emission OFF, bank 1 and 2 switching, bank 1 through 8 switching, or zero reset. |
— | ||
Changing the displays | Threshold level and incident level, channel number and incident level, RGB display and incident level, or bank display and incident level |
||||
Ambient illumination (Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
Ambient temperature range | Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) within the surrounding air temperature range shown above |
||||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
Vibration resistance | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each in X, Y, and Z directions |
|||
Weight (packed state/Sensor only) |
Approx. 115 g/ approx. 75 g |
Approx. 60g/ approx. 20g |
Approx. 115 g/ approx. 75 g |
Approx. 65 g/approx. 25 g | |
Mate- rials |
Case | Polycarbonate (PC) | |||
Cover | Polycarbonate (PC) | ||||
Cable covering | Polyvinyl chloride (PVC) | — | |||
Accessories | Instruction manual |
*1. The E3NW-ECT Sensor Communications Unit can be used, but the E3NW-CRT/CCL, E3X-DRT21-S, and E3X-CRT/ECT
Sensor Communications Units cannot be used.
*2. The following details apply to the input.
Contact input (relay or switch) | Non-contact input (transistor) | |
---|---|---|
NPN | ON: Shorted to 0 V (Sourcing current: 2 mA max.). OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (Sourcing current: 2 mA max.) OFF: Vcc – 1.5 V to Vcc (Leakage current: 0.1 mA max.) |
PNP | ON: Shorted to Vcc (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V. |
ON: Vcc – 1.5 V to Vcc (sinking current: 3 mA max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.) |
*3. Two sensor outputs are allocated in the programmable logic controller (PLC) I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*4. Power consumption
At Power Supply Voltage of 10 to 30 VDC
Normal mode: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 74 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 50mA max. at 10 VDC)
Eco function LO: 930 mW max. (Current consumption: 31 mA max. at 30 VDC, 55 mA max. at 10 VDC)
*5. The mutual interference prevention function is disabled if the detection mode is set to Super-high-speed Mode.
*6. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
*7. The bank is not reset by the user reset function or saved by the user save function.
Sensing Distances
Specifications
Hex-shaped Models
Type | Appearance (mm) |
Bending radius of cable (mm) |
Sensing distance (mm) | Model | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensing method |
Size | Aper- ture angle |
White paper | 12-color discrimination |
|||||||||
GIGA | ST | HS | SHS | GIGA | ST | HS | SHS | ||||||
Reflective | M6 | 60° | Flexible, R4 |
90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 | E32-C91N 2M |
Through-beam Models (Grooved Type)
Type | Sensing width |
Appearance (mm) |
Bending radius of cable (mm) |
Sensing distance (mm) | Model | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Opaque object | Translucent object | |||||||||||
GIGA | ST | HS | SHS | GIGA | ST | HS | SHS | |||||
Array | 10 mm | R5 | 10 | E32-G16 2M |
Installation Information
Model | Installation | Cable | Weight (packed state) |
|||||||
---|---|---|---|---|---|---|---|---|---|---|
Ambient temper- ature |
Tight- ening torque |
Mounting hole |
Bend- ing radius (mm) |
Unbendable length (mm) |
Tensile strength |
Sheath material |
Core ma- terial |
Emitter/ receiver differen- tiation |
||
E32-C91N 2M |
-40 to 70°C |
0.98 N·m |
6.2 +0.5, 0 dia. |
R4 | 0 | 29.4 N | Polyeth- ylene |
Plastic | White line on emitter cable |
36 g |
E32-G16 2M |
-40 to 70°C |
0.53 N·m |
— | R5 | 0 * | 29.4 N | Polyeth- ylene |
Plastic | — | 51 g |
* The bending radius of the protective cover (PVC, 25 mm) is 10 mm min.
Hex-shaped Models
Sensing method |
Size | Aper- ture angle |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
||||
Through- beam |
M4 | 15° | E32-LT11N 2M (Built-in Lens) |
980 | 510 | 350 | 140 | 190 | 100 | 70 | 44 |
60° | E32-T11N 2M | 300 | 150 | 100 | 45 | 60 | 31 | 21 | 13 | ||
Reflective | M3 | E32-C21N 2M | 54 | 27 | 18 | 7 | 10 | 5 | 3.6 | 2.6 | |
M4 | E32-D21N 2M | 90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 | ||
M6 | 15° | E32-LD11N 2M (Built-in Lens) |
88 | 44 | 29 | 13 | 17 | 8 | 5 | 4 | |
M3 | 60° | E32-C31N 2M | 12 | 6 | 4 | 1.8 | 2.4 | 1.2 | 0.8 | 0.6 | |
M6 | E32-C11N 2M | 90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 | ||
Retro- reflective for transparent object detection |
15° | E32-LR11NP 2M (Built-in Lens) + E39-RP1 (Reflector, sold separately) |
370 | 180 | 120 | 55 | 75 | 37 | 25 | 16 |
*1. These sensing distances are recommended to make the most of the detection capabilities of the Sensor.
*2. The Super-high-speed Mode for 12-color discrimination with a Reflective Sensor or for detection of translucent objects with a Through-beam Sensor can be set only in Contrast Mode. The Super-high-speed Mode can not be set in Color Mode.
Threaded Models
Sensing method |
Size | Aperture angle |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
||||
Through- beam |
M4 | 60° | E32-T11R 2M | 300 | 150 | 100 | 45 | 60 | 31 | 21 | 13 |
15° | E32-LT11 2M (Built-in Lens) |
1,150 | 600 | 410 | 170 | 230 | 120 | 82 | 52 | ||
E32-LT11R 2M (Built-in Lens) |
980 | 510 | 350 | 140 | 190 | 100 | 70 | 44 | |||
Reflective | M6 | E32-LD11 2M (Built-in Lens) |
92 | 46 | 30 | 13 | 18 | 9 | 6 | 4 | |
E32-LD11R 2M (Built-in Lens) |
88 | 44 | 29 | 13 | 17 | 8 | 5 | 4 | |||
M3 | 60° | E32-C31 2M | 37 | 18 | 12 | 5 | 7 | 3.8 | 2.5 | 1.8 | |
M6 | E32-D11R 2M | 90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 | ||
E32-CC200 2M | 150 | 75 | 50 | 22 | 30 | 15 | 10 | 7 |
Cylindrical Models
Sensing method |
Sensing direction |
Size | Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
||||||||||
GIGA | Standard | High-speed | Super high-speed | GIGA | Standard | High- speed |
Super high-speed *2 |
||||
Through- beam |
Top-view | 1.5 dia. | E32-T22B 2M | 110 | 64 | 37 | 16 | 22 | 12 | 7 | 5 |
3 dia. | E32-T12R 2M | 300 | 150 | 100 | 45 | 60 | 31 | 21 | 13 | ||
Side-view | E32-T14LR 2M | 190 | 100 | 68 | 29 | 38 | 20 | 13 | 8 | ||
Reflective | Top-view | 1.5 dia. | E32-D22B 2M | 17 | 8 | 6 | 2.4 | 3 | 2 | 1.2 | 0.7 |
3 dia. | E32-D221B 2M | 38 | 20 | 13 | 5 | 7 | 4 | 3 | 1.7 | ||
E32-D32L 2M | 85 | 44 | 30 | 12 | 17 | 8 | 6 | 3.7 |
Flat Models
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
|||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
|||
Through- beam |
Flat-view | E32-LT35Z 2M (Built-in Lens) |
360 | 190 | 130 | 55 | 73 | 38 | 26 | 16 |
Top-view | E32-T15XR 2M | 300 | 150 | 100 | 45 | 60 | 31 | 21 | 13 | |
Side-view | E32-T15YR 2M | 190 | 100 | 68 | 29 | 38 | 20 | 13 | 8 | |
Flat-view | E32-T15ZR 2M | 190 | 100 | 68 | 29 | 38 | 20 | 13 | 8 | |
Reflective | Top-view | E32-D15XR 2M | 90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 |
Side-view | E32-D15YR 2M | 21 | 10 | 7 | 3.1 | 4.2 | 2.1 | 1.4 | 1 | |
Flat-view | E32-D15ZR 2M | 21 | 10 | 7 | 3.1 | 4.2 | 2.1 | 1.4 | 1 |
Sleeve Models
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
|||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
|||
Through- beam |
Top-view | E32-TC200BR 2M | 300 | 150 | 100 | 45 | 60 | 31 | 21 | 13 |
Reflective | E32-DC200BR 2M | 90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 |
*1. These sensing distances are recommended to make the most of the detection capabilities of the Sensor.
*2. The Super-high-speed Mode for 12-color discrimination with a Reflective Sensor or for detection of translucent objects with a Through-beam Sensor can be set only in Contrast Mode. The Super-high-speed Mode can not be set in Color Mode.
Small-spot, Reflective Models
Sens- ing meth- od |
Type | Spot diam- eter |
Cen- ter dis- tance (mm) |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
White paper | 12-color discrimination | |||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
|||||
Re- flective |
Inte- grated lens, long- distance, small- spot |
6 dia. |
50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. Sensing distance of 40 to 100 mm. |
Spot diameter of 6 mm at 50 mm. Sensing distance of 40 to 85 mm. |
Spot diam- eter of 6 mm at 50 mm. Sensing distance of 40 to 60 mm. |
|||||
Parallel light |
4 dia. |
0 to 20 |
E32-C31 2M + E39-F3C |
Spot diameter of 4 mm at 0 to 20 mm. |
Spot diameter of 4 mm at 1 to 9 mm. *3 |
— | ||||||
Small- spot |
0.5 dia. |
7 | E32-C31 2M + E39-F3A-5 |
Spot diameter of 0.5 mm at 7 mm. |
— | Spot diameter of 0.5 mm at 7 mm. *3 |
— | |||||
17 | E32-C31 2M + E39-F3B |
Spot diameter of 0.5 mm at 17 mm. |
— | — | ||||||||
3 dia. |
50 | E32-CC200 2M + E39- F18 |
Spot diameter of 3 mm at 50 mm. |
— | Spot diameter of 3 mm at 50 mm. *3 |
— |
High-power Beam Models
Sensing method |
Sensing direction |
Aper- ture angle |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Opaque object | Translucent object *1 | ||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
||||
Through- beam |
Top-view | 10° | E32-T17L 10M | 8,570 | 200 | 130 | 59 | 1,710 | 40 | 27 | 17 |
Side-view | 30° | E32-T14 2M | 1,910 | 990 | 680 | 290 | 380 | 190 | 130 | 87 | |
Right-angle | 12° | E32-T11N 2M + E39-F1 |
1,470 | 760 | 520 | 220 | 290 | 150 | 100 | 66 | |
Top-view | 12° | E32-T11R 2M + E39-F1 |
1,470 | 760 | 520 | 220 | 290 | 150 | 100 | 66 | |
Side-view | 60° | E32-T11R 2M + E39-F2 |
180 | 98 | 67 | 28 | 37 | 19 | 13 | 8 | |
Top-view | 12° | E32-T11 2M + E39-F1 |
2,430 | 1,260 | 860 | 360 | 480 | 250 | 170 | 110 | |
Side-view | 60° | E32-T11 2M + E39-F2 |
310 | 160 | 110 | 47 | 62 | 32 | 22 | 14 | |
Top-view | 12° | E32-T61-S 2M + E39-F1 |
1,080 | 560 | 380 | 160 | 210 | 110 | 76 | 49 | |
Side-view | 60° | E32-T61-S 2M + E39-F2 |
130 | 72 | 49 | 21 | 27 | 14 | 9 | 6 |
Narrow View Models
Sensing method |
Sensing direction |
Aper- ture angle |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Opaque object | Translucent object *1 | ||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
||||
Through- beam |
Side-view | 4° | E32-T24S 2M | 750 | 380 | 260 | 110 | 150 | 77 | 53 | 34 |
E32-T22S 2M | 1,070 | 550 | 380 | 160 | 210 | 110 | 76 | 48 |
Chemical-resistant, Oil-resistant Models
Sensing method |
Type | Sensing direction |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
||||
Through- beam |
Chemical/ oil resistant |
Top-view | E32-T12F 2M | 1,710 | 880 | 600 | 260 | 340 | 170 | 120 | 78 |
E32-T11F 2M | 250 | 130 | 91 | 39 | 51 | 26 | 18 | 11 | |||
Side-view | E32-T14F 2M | 210 | 110 | 76 | 32 | 42 | 22 | 15 | 9 | ||
Chemical/ oil-resistant at 150°C |
Top-view | E32-T51F 2M | 770 | 400 | 270 | 110 | 150 | 80 | 54 | 35 | |
Reflective | Chemical/ oil resistant |
Top-view | E32-D12F 2M | 49 | 24 | 16 | 7 | 9 | 5 | 3 | 2.4 |
Chemical- resistant cable |
E32-D11U 2M | 90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 |
*1. These sensing distances are recommended to make the most of the detection capabilities of the Sensor.
*2. The Super-high-speed Mode for 12-color discrimination with a Reflective Sensor or for detection of translucent objects
with a Through-beam Sensor can be set only in Contrast Mode. The Super-high-speed Mode can not be set in Color
Mode.
*3. The sensing distances are given for Contrast Mode. The sensing distance cannot be set in Color Mode.
Bending-resistant Models
Sensing method |
Size | Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
|||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
|||
Through- beam |
1.5 dia. | E32-T22B 2M | 110 | 64 | 37 | 16 | 22 | 12 | 7 | 5 |
M3 | E32-T21 2M | 100 | 57 | 33 | 14 | 20 | 11 | 6 | 4 | |
M4 | E32-T11 2M | 380 | 200 | 130 | 58 | 77 | 40 | 27 | 17 | |
Square | E32-T25XB 2M | 77 | 43 | 25 | 10 | 15 | 8 | 5 | 3.3 | |
Reflective | 1.5 dia. | E32-D22B 2M | 17 | 8 | 6 | 2.4 | 3 | 2 | 1.2 | 0.7 |
M3 | E32-D21 2M | 17 | 8 | 6 | 2.4 | 3.4 | 1.8 | 1.2 | 0.7 | |
3 dia. | E32-D221B 2M | 38 | 20 | 13 | 5 | 7 | 4 | 3 | 1.7 | |
M4 | E32-D21B 2M | 38 | 20 | 13 | 5 | 7 | 4 | 2.7 | 1.7 | |
M6 | E32-D11 2M | 90 | 45 | 30 | 13 | 18 | 9 | 6 | 4 | |
Square | E32-D25XB 2M | 27 | 14 | 9 | 3.9 | 5 | 3 | 2 | 1.2 |
Heat-resistant Models
Sensing method |
Heat- resistant temperature |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
|||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
|||
Through- beam |
150° | E32-T51 2M | 420 | 220 | 150 | 65 | 85 | 44 | 30 | 19 |
200° | E32-T81R-S 2M | 150 | 80 | 54 | 23 | 30 | 16 | 10 | 7 | |
350° | E32-T61-S 2M | 250 | 130 | 91 | 39 | 51 | 26 | 18 | 11 | |
Reflective | 150° | E32-D51 2M | 120 | 60 | 40 | 17 | 24 | 12 | 8 | 5 |
200° | E32-D81R-S 2M | 42 | 21 | 14 | 6 | 8 | 4.3 | 2.9 | 1.9 | |
350° | E32-D61-S 2M | 42 | 21 | 14 | 6 | 8 | 4 | 2.9 | 1.9 | |
400° | E32-D73-S 2M | 28 | 14 | 9 | 4 | 5 | 2.9 | 1.9 | 1.3 |
Area Detection Models
Sensing method | Type | Sensing width |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Reflective: White paper, Through-beam: Opaque object |
Reflective: 12-color discrimination, Through-beam: Translucent object *1 |
||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
||||
Through- beam |
Area | 11 mm | E32-T16PR 2M | 480 | 250 | 170 | 73 | 96 | 50 | 34 | 21 |
E32-T16JR 2M | 410 | 210 | 140 | 63 | 83 | 43 | 29 | 19 | |||
30 mm | E32-T16WR 2M | 730 | 210 | 140 | 63 | 140 | 43 | 29 | 19 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 75 | 37 | 25 | 11 | 15 | 7 | 5 | 3.3 |
Vacuum-resistant Models
Sensing method |
Type | Heat- resistant tempera- ture |
Model | Sensing distance (mm) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Opaque object | Translucent object *1 | ||||||||||
GIGA | Stand- ard |
High- speed |
Super- high- speed |
GIGA | Stand- ard |
High- speed |
Super- high- speed *2 |
||||
Through- beam |
Vacuum side |
120° | E32-T51V 1M | 110 | 57 | 39 | 16 | 22 | 11 | 7 | 5 |
E32-T51V 1M + E39-F1V |
170 | 90 | 61 | 26 | 34 | 18 | 12 | 7 | |||
200° | E32-T84SV 1M | 270 | 140 | 97 | 41 | 54 | 28 | 19 | 12 |
*1. These sensing distances are recommended to make the most of the detection capabilities of the Sensor.
*2. The Super-high-speed Mode for 12-color discrimination with a Reflective Sensor or for detection of translucent objects
with a Through-beam Sensor can be set only in Contrast Mode. The Super-high-speed Mode can not be set in Color
Mode.
Dimensions | Fiber Amplifier Sensor – E3NX-CA series
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Fiber Amplifier Units
Pre-wired Amplifier Units
E3NX-CA11
E3NX-CA41
E3NX-CA21
E3NX-CA51
Amplifier Units with Wire-saving Connectors
E3NX-CA6
E3NX-CA8
Amplifier Unit with Connector for Sensor Communications Unit
E3NX-CA0
Fiber Units
Reflective Models
E32-C91N
Through-beam Models (Grooved Type)
E32-G16
Accessories (Sold Separately)
Wire-saving Connectors
Master Connector
E3X-CN11
Slave Connector
E3X-CN12
Mounting Bracket
E39-L143
DIN Tracks
PFP-100N
PFP-50N
PFP-100N2
End Plate
PFP-M
คุณสมบัติ | Fiber Sensor Amplifier – E3NX-CA series
- ตรวจจับความแตกต่างเล็กน้อยของสี ออปติก LED สีขาวระบบใหม่เพิ่มความความเข้มของแสงและวงจรสัญญาณรบกวนต่ำใน Smart Fiber Amplifier Unit ให้ความสามารถในตรวจจับที่น่าทึ่ง
- จับชิ้นงานมันวาวได้ Smart Tuning ช่วยให้คุณคั้งค่าความไวในการตรวจจับที่เหมาะสมที่สุดด้วยการใช้งานง่ายๆ เพียงครั้งเดียว
- รองรับ IoT ข้อมูล RGB ที่ตรวจพบสามารถแสดงบน Amplifier Unit และ Amplifer Unit สำหรับการสื่อสารสามารถ ถ่ายโอนข้อมูลนี้ไป ยังโฮลต์แบบเรียลไทม์
คุณสมบัติ | Fiber Sensor Amplifier – E3NX-CA series
Fiber Sensor Amplifier | E3NX-CA series |
---|---|
แรงดันไฟฟ้า | 10 – 30 VDC |
เอาต์พุต I/O | 1 เอาต์พุต, 2 เอาต์พุต |
อินพุตภายนอก I/O | 1 อินพุต |
ยูนิตเชื่อมต่อสูงสุด | 30 ยูนิต |
น้ำหนัก (สถานะบรรจุ / เฉพาะเซ็นเซอร์) (กรัม) | ประมาน 115/75, 60/20, 65/25 |
วัสดุ | โพลีคาร์บอเนต (PC) |