OMRON Counter - H7GP
Model Numbers | Counter – H7GP
Total counter
<thcolspan=”2″>6-digit total counter
Supply voltage | ||
---|---|---|
Light gray | Black | |
100 to 240 VAC | H7GP-C | H7GP-CB |
12 to 24 VDC | H7GP-CD | H7GP-CDB |
Time counter
Supply voltage | 6-digit time counter | |
---|---|---|
Light gray | Black | |
100 to 240 VAC | H7GP-T | H7GP-TB |
12 to 24 VDC | H7GP-TD | H7GP-TDB |
Specifications | Counter – H7GP
Ratings
Item | 6-digit total counter | 6-digit time counter | |||
---|---|---|---|---|---|
H7GP-C | H7GP-CD | H7GP-T | H7GP-TD | ||
Rated supply voltage | 100 to 240 VAC (50/60 Hz) |
12 to 24 VDC *1 | 100 to 240 VAC (50/60 Hz) |
12 to 24 VDC *1 | |
External power supply | 50 mA at 12 VDC | — | 50 mA at 12 VDC | — | |
Operating voltage range | 85% to 110% of rated supply voltage | ||||
Power consumption | 100 to 240 VAC: 6.5 VA max. 12 to 24 VDC: 0.6 W max. |
||||
Dimensions | 48 x 24 x 80 mm (W x H x D) | ||||
Mounting method | Flush mounting | ||||
External connections | Screw terminals | ||||
Degree of protection | Panel surface: IP66 with oil resistance and NEMA Type 4 (indoors). | ||||
Display | 7-segment, negative transmissive LCD (with red backlight) | ||||
Digits | 6 digits (8.5-mm-high characters) | ||||
Input mode | Up (increment) | Accumulative | |||
Max. counting speeds | 30 Hz or 5 kHz (selected via DIP switch) | — | |||
Counting range | 0 to 999999 | — | |||
Time specification | — | 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s (selected via DIP switch) |
|||
Timing accuracy | — | ±100 ppm (-10°C to 55°C) | |||
Memory backup | EEP-ROM (overwrites: 200,000 times min.) that can store data for 20 years min. | ||||
Input | Input signals | Count, reset, and key protection *2 | Start, reset, and key protection *2 | ||
Input method | No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch) |
||||
Count, reset, start |
No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage:2 VDC max. Open (OFF) impedance: 100 kΩ min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 kΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ min. |
||||
Key protection | No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage:0.5 VDC max. Open (OFF) impedance: 100 kΩ min. |
||||
Input response speed |
Reset | 20 or 1 ms (automatically switched according to counting speed) |
20 ms | ||
Start | — | 20 ms | |||
Key protection | Approx. 1 s | Approx. 1 s | |||
Reset system | External and manual resets |
*1. Contains 20% ripple (p-p) max.
*2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional.
Characteristics
Insulation resistance | 100 MΩ min. (at 500 VDC) |
---|---|
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current- carrying metal parts (AC model) 1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current- carrying metal parts (DC model) 2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model) |
Impulse withstand voltage |
3 kV (between power terminals) (1 kV for 12-to-24-VDC models) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC models) |
Noise immunity | ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals), ±480 V (between input terminals); square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
Static immunity | Display: Malfunction: 8 kV, Destruction: 15 kV DIP switch: Malfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions |
Shock resistance | Destruction: 294 m/s2 each in three directions Malfunction: 196 m/s2 each in three directions |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
EMC | (EMI) EN61326-1 (note 1.) Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61326-1 (note 1.) Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) |
Approved standards | UL508 (note 2), CSA C22.2 No.14 (note 2), conforms to EN61010-1, VDE0106/P100 |
Case color | Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black) |
Weight | Approx. 75 g |
- Note:
- Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
- UL508 and CAN/CSA-C22.2 No.14 certification conditions)
- Power supply 100 to 240VAC types
- Ambient temperature 30°C Single mounting
- Power supply 12 to 24VDC types
- Ambient temperature 40°C Single mounting
- Power supply 100 to 240VAC types
Dimensions | Counter – H7GP
H7GP-C
H7GP-T
With Flush Mounting Bracket
Panel Cutouts
Panel cutouts are as shown below (according to DIN43700).
Note:The mounting panel thickness should be 1 to 6 mm.
Note:Water resistance will be lost if Counters are mounted side-by-side.
Note:The terminal screws are M3.5.
(Theeffective thread length is 6 mm.)
Note:When horizontally mounting Counters side-by-side, leave at least 50 mm between any two Counters.
Features | Counter – H7GP
IP66 with oil resistance and NEMA 4 Compact body Just change a switch setting for either an NPN or PNP input Complies with EMC standards (EN 61326) and CE Marking
Properties | Counter – H7GP
Counter | H7CX-R |
---|---|
Power supply | 100 – 240 Vac (50 – 60Hz) 24 Vac (50 – 60Hz) 10 – 24 Vdc |
Max counting speed | 30 Hz |
Input method | No-voltage (NPN) input/voltage (PNP) input |
High (logic) level: 4.5 to 30 VDC, Low (logic) level: 0 to 2 VDC | |
Output | Contact output: 3 A at 250 VAC/30 VDC |
Reset system | External |
automatic reset | |
Dimensions (W x L x H) |
24 x 48 x 80 |
Weight (g) | 75 |