Diffuse-reflective Sensor Heads
Model | ZX2-LD50L | ZX2-LD50 | ZX2-LD100L | ZX2-LD100 |
---|---|---|---|---|
Optical system | Diffuse reflective | |||
Light source (wave length) |
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 1mW max. | |||
EN class 2, FDA class 2 *5 | ||||
Measurement center point |
50 mm | 100 mm | ||
Measurement range | ±10 mm | ±35 mm | ||
Beam shape | Line | Spot | Line | Spot |
Beam size *1 | Approx. 60 μm × 2.6 mm |
Approx. 60 μm dia. | Approx.110 μm × 2.7 mm |
Approx.110 μm dia. |
Resolution *2 | 1.5μm | 5μm | ||
Linearity *3 | ±0.05% F.S. (40 to 50 mm) |
±0.1% F.S. (40 to 50 mm) |
±0.05% F.S. (65 to 100 mm) |
±0.1% F.S. (65 to 100 mm) |
Temperature characteristic *4 |
0.02% F.S./°C | |||
Ambient illumination | Incandescent lamp: 10,000 lx max. (on light receiving side) | |||
Ambient temperature | Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) | |||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min. | |||
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions | |||
Shock resistance (destruction ) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) | |||
Degree of protection | IEC60529, IP67 | |||
Connection method | Connector connection (standard cable length: 500 mm) | |||
Weight (packed state) | Approx. 160 g (main unit only: Approx. 75 g) | |||
Materials | Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC | |||
Accessories | Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser warning label (English), FDA |
Regular-reflective Sensor Head
Model | ZX2-LD50L |
---|---|
Optical system | Regular reflective |
Light source (wave length) | Visible-light semiconductor laser with a wavelength of 660 nm and an output of 0.24 mW max. EN class 1, FDA class 1 *5 |
Measurement center point | 48 mm |
Measurement range | ±5 mm |
Beam shape | Spot |
Beam size *1 | Approx. 60 μm dia. |
Resolution *2 | 1.5 μm |
Linearity *3 | ±0.3%F.S. (entire range) |
Temperature characteristic *4 |
0.06%F.S./°C |
Ambient illumination | Incandescent lamp: 10,000lx max. (on light receiving side) |
Ambient temperature | Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute |
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions |
Shock resistance (destruction) |
300 m/s2 3 times each in six directions (up/down,left/right,forward/backward) |
Degree of protection | IEC 60529, IP67 |
Connection method | Connector connection (standard cable length: 500 mm) |
Weight (packed state) | Approx.160g (Sensor Head only: Approx.75g) |
Materials | Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC |
Accessories | Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser warning label (English), FDA |
Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
- Beam size: Defined as 1/e2 (13.5 %) of the center optical intensity at the minimum value of the measurement range (effective value). False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object. Correct measurements may not be obtained if the workpiece is smaller than the beam size.
- Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA. (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models : white ceramic object, regular-reflective models:1/4 λ flat mirror) when the response time of the ZX2-LDA is set to 128 ms.) Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field.
- Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object. Linearity and measured value may vary depending on target object. F.S. indicates the full scope of the measurement range. (ZX2-LD50(L): 20 mm)
- Temperature characteristic: Value for the case the space between the sensor head and Omron’ s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
- These Sensors are classified as Class 2 laser devices for diffuse-reflective models and Class 1 for regular-reflective models under IEC 60825-1 and the regulations of Laser Notice No. 50 for FDA certification. CDRH registration has been completed.
Amplifier Units
Model | ZX2-LDA11 | ZX2-LDA41 |
---|---|---|
Measurement period *1 | Min. 30 μs | |
Response time | 60 μs, 120 μs, 240 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms, 12 ms, 20 ms, 36 ms, 66 ms, 128 ms, 250 ms, 500ms |
|
Analog output *2 | 4 to 20 mA, Max. load resistance: 300Ω/±5 VDC or 1 to 5 VDC, Output impedance: 100Ω | |
Judgement outputs (HIGH/PASS/LOW: 3 outputs), error output |
NPN open-collector outputs, 30 VDC, 50 mA max. (residual voltage: 1 V max. for load current 10 mA max., 2V max. for load current above 10 mA) |
PNP open-collector outputs, 30 VDC, 50 mA max. (residual voltage: 1 V max. for load current 10 mA max., 2 V max. for load current above 10 mA) |
Laser OFF input, zero reset input, timing input, reset input, bank input |
ON: Short-circuited with 0-V terminal or 1.2 V or less OFF: Open (leakage current: 0.1 mA max.) |
ON: Supply voltage short-circuited or supply voltage within -1.2 V OFF: Open (leakage current: 0.1 mA max.) |
Functions | Smart tuning, scaling, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak hold, self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/ clamp switch, (A-B) calculations *3, thickness calculation *3, mutual interference prevention *3, laser deterioration detection, bank function (4 banks), differential function |
|
Indications | Judgement indicators: HIGH (orange), PASS (green), LOW (orange), 11-segment main display (red), 11-segment sub-display (orange), laser ON (green), zero reset (green), enable (green), menu (green), HIGH threshold (orange), LOW threshold (orange) |
|
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |
Power consumption | 3,000 mW max. (at 24 VDC: 125 mA max., at 12 VDC: 250 mA max.) | |
Ambient temperature | Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) | |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min. | |
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions | |
Shock resistance (destruction) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) | |
Degree of protection | IEC60529, IP40 | |
Connection method | Prewired (standard cable length: 2 m) | |
Weight (packed state) | Approx. 200 g (main unit only: Approx. 135 g) | |
Materials | Case: PBT (polybutylene terephtahalate), Cover: Polycarbonate, Display: Methacrylic resin, Button: Polyacetal, Cable: PVC |
|
Accessories | Instruction sheet |
- In the case of Omron’s standard target object (white ceramic)
- Select current output (4 to 20 mA) and voltage output (±5V or 1 to 5V) by MENU mode.
- Calculating unit (ZX2-CAL) is necessary. Calculations are possible for up to two amplifier units. Mutual interference prevention is possible for up to five amplifier units.
Calculating Unit
Model | ZX2-CAL |
---|---|
Applicable Amplifier Units | ZX2-LDA11, ZX2-LDA41 |
Current consumption | 12 mA max. (supplied from the Smart Sensor Amplifier Unit) |
Ambient temperature | Operating: 0 to +50°C, storage: -15 to +70°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Connection method | Connector |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute |
Vibration resistance (destruction) | 10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions |
Shock resistance (destruction) | 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
Materials | Case: ABS, Display: Methacrylic resin |
Weight (packed state) | Approx. 50g (Calculating Unit only: Approx. 15g) |
Accessories | Instruction sheet |
ZX2-series Communications Interface Unit
Model | ZX2-SF11 | ||
---|---|---|---|
Power supply voltage | 10 to 30 V DC ±10% (including 10% ripple (p-p)) (Supplied from Sensor Amplifier.) |
||
Power consumption | 720 mW max. (at 24 V: 30 mA max., at 12 V: 60 mA max.) (Not including Sensor Amplifier current consumption or output current |
||
Applicable Amplifier Units | ZX2-LDA[][] (Production after November 2013) | ||
Applicable Amplifier Unit versions |
Sensor Amplifier Unit version: V1.330 or higher (The Sensor Amplifier version is shown on the sub-digital display when the power of the Sensor Amplifier is turned ON.) |
||
Max. No. of Amplifier Units |
5 | ||
Commu- nications functions |
Port | RS-232C (9-pin, D-Sub connector) | |
Communications method | Full duplex | ||
Synchronization method | Start/stop synchronization | ||
Transmission code | ASCII | ||
Baud rate | 38,400 (at shipping)/9,600 bps switchable | ||
Data bit length | 8 bits | ||
Parity check | None | ||
Stop bit length | 1 bit | ||
Data delimiter |
Receiving | CR or CR + LF is automatically recognized. | |
Sending | CR + LF fixed | ||
Indicators | Power supply: green, Sensor communications: green, Sensor communications error: red, External terminal communications: green, External terminal communications error: red |
||
Protective circuits | Power supply reverse polarity protection | ||
Ambient temperature | Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) |
||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max. |
||
Materials | Case: PBT (polybutylene terephthalate), Cover: Polycarbonate | ||
Accessories | Instruction sheet, 2 clamps |
Specifications | Photoelectric Displacement Sensor – ZX2 series
Diffuse-reflective Sensor Heads
Model | ZX2-LD50L | ZX2-LD50 | ZX2-LD100L | ZX2-LD100 |
---|---|---|---|---|
Optical system | Diffuse reflective | |||
Light source (wave length) |
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 1mW max. | |||
EN class 2, FDA class 2 *5 | ||||
Measurement center point |
50 mm | 100 mm | ||
Measurement range | ±10 mm | ±35 mm | ||
Beam shape | Line | Spot | Line | Spot |
Beam size *1 | Approx. 60 μm × 2.6 mm |
Approx. 60 μm dia. | Approx.110 μm × 2.7 mm |
Approx.110 μm dia. |
Resolution *2 | 1.5μm | 5μm | ||
Linearity *3 | ±0.05% F.S. (40 to 50 mm) |
±0.1% F.S. (40 to 50 mm) |
±0.05% F.S. (65 to 100 mm) |
±0.1% F.S. (65 to 100 mm) |
Temperature characteristic *4 |
0.02% F.S./°C | |||
Ambient illumination | Incandescent lamp: 10,000 lx max. (on light receiving side) | |||
Ambient temperature | Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) | |||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min. | |||
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions | |||
Shock resistance (destruction ) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) | |||
Degree of protection | IEC60529, IP67 | |||
Connection method | Connector connection (standard cable length: 500 mm) | |||
Weight (packed state) | Approx. 160 g (main unit only: Approx. 75 g) | |||
Materials | Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC | |||
Accessories | Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser warning label (English), FDA |
Regular-reflective Sensor Head
Model | ZX2-LD50L |
---|---|
Optical system | Regular reflective |
Light source (wave length) | Visible-light semiconductor laser with a wavelength of 660 nm and an output of 0.24 mW max. EN class 1, FDA class 1 *5 |
Measurement center point | 48 mm |
Measurement range | ±5 mm |
Beam shape | Spot |
Beam size *1 | Approx. 60 μm dia. |
Resolution *2 | 1.5 μm |
Linearity *3 | ±0.3%F.S. (entire range) |
Temperature characteristic *4 |
0.06%F.S./°C |
Ambient illumination | Incandescent lamp: 10,000lx max. (on light receiving side) |
Ambient temperature | Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute |
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions |
Shock resistance (destruction) |
300 m/s2 3 times each in six directions (up/down,left/right,forward/backward) |
Degree of protection | IEC 60529, IP67 |
Connection method | Connector connection (standard cable length: 500 mm) |
Weight (packed state) | Approx.160g (Sensor Head only: Approx.75g) |
Materials | Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC |
Accessories | Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser warning label (English), FDA |
Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
- Beam size: Defined as 1/e2 (13.5 %) of the center optical intensity at the minimum value of the measurement range (effective value). False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object. Correct measurements may not be obtained if the workpiece is smaller than the beam size.
- Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA. (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models : white ceramic object, regular-reflective models:1/4 λ flat mirror) when the response time of the ZX2-LDA is set to 128 ms.) Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field.
- Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object. Linearity and measured value may vary depending on target object. F.S. indicates the full scope of the measurement range. (ZX2-LD50(L): 20 mm)
- Temperature characteristic: Value for the case the space between the sensor head and Omron’ s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
- These Sensors are classified as Class 2 laser devices for diffuse-reflective models and Class 1 for regular-reflective models under IEC 60825-1 and the regulations of Laser Notice No. 50 for FDA certification. CDRH registration has been completed.
Amplifier Units
Model | ZX2-LDA11 | ZX2-LDA41 |
---|---|---|
Measurement period *1 | Min. 30 μs | |
Response time | 60 μs, 120 μs, 240 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms, 12 ms, 20 ms, 36 ms, 66 ms, 128 ms, 250 ms, 500ms |
|
Analog output *2 | 4 to 20 mA, Max. load resistance: 300Ω/±5 VDC or 1 to 5 VDC, Output impedance: 100Ω | |
Judgement outputs (HIGH/PASS/LOW: 3 outputs), error output |
NPN open-collector outputs, 30 VDC, 50 mA max. (residual voltage: 1 V max. for load current 10 mA max., 2V max. for load current above 10 mA) |
PNP open-collector outputs, 30 VDC, 50 mA max. (residual voltage: 1 V max. for load current 10 mA max., 2 V max. for load current above 10 mA) |
Laser OFF input, zero reset input, timing input, reset input, bank input |
ON: Short-circuited with 0-V terminal or 1.2 V or less OFF: Open (leakage current: 0.1 mA max.) |
ON: Supply voltage short-circuited or supply voltage within -1.2 V OFF: Open (leakage current: 0.1 mA max.) |
Functions | Smart tuning, scaling, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak hold, self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/ clamp switch, (A-B) calculations *3, thickness calculation *3, mutual interference prevention *3, laser deterioration detection, bank function (4 banks), differential function |
|
Indications | Judgement indicators: HIGH (orange), PASS (green), LOW (orange), 11-segment main display (red), 11-segment sub-display (orange), laser ON (green), zero reset (green), enable (green), menu (green), HIGH threshold (orange), LOW threshold (orange) |
|
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |
Power consumption | 3,000 mW max. (at 24 VDC: 125 mA max., at 12 VDC: 250 mA max.) | |
Ambient temperature | Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) | |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min. | |
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions | |
Shock resistance (destruction) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) | |
Degree of protection | IEC60529, IP40 | |
Connection method | Prewired (standard cable length: 2 m) | |
Weight (packed state) | Approx. 200 g (main unit only: Approx. 135 g) | |
Materials | Case: PBT (polybutylene terephtahalate), Cover: Polycarbonate, Display: Methacrylic resin, Button: Polyacetal, Cable: PVC |
|
Accessories | Instruction sheet |
- In the case of Omron’s standard target object (white ceramic)
- Select current output (4 to 20 mA) and voltage output (±5V or 1 to 5V) by MENU mode.
- Calculating unit (ZX2-CAL) is necessary. Calculations are possible for up to two amplifier units. Mutual interference prevention is possible for up to five amplifier units.
Calculating Unit
Model | ZX2-CAL |
---|---|
Applicable Amplifier Units | ZX2-LDA11, ZX2-LDA41 |
Current consumption | 12 mA max. (supplied from the Smart Sensor Amplifier Unit) |
Ambient temperature | Operating: 0 to +50°C, storage: -15 to +70°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Connection method | Connector |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute |
Vibration resistance (destruction) | 10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions |
Shock resistance (destruction) | 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
Materials | Case: ABS, Display: Methacrylic resin |
Weight (packed state) | Approx. 50g (Calculating Unit only: Approx. 15g) |
Accessories | Instruction sheet |
ZX2-series Communications Interface Unit
Model | ZX2-SF11 | ||
---|---|---|---|
Power supply voltage | 10 to 30 V DC ±10% (including 10% ripple (p-p)) (Supplied from Sensor Amplifier.) |
||
Power consumption | 720 mW max. (at 24 V: 30 mA max., at 12 V: 60 mA max.) (Not including Sensor Amplifier current consumption or output current |
||
Applicable Amplifier Units | ZX2-LDA[][] (Production after November 2013) | ||
Applicable Amplifier Unit versions |
Sensor Amplifier Unit version: V1.330 or higher (The Sensor Amplifier version is shown on the sub-digital display when the power of the Sensor Amplifier is turned ON.) |
||
Max. No. of Amplifier Units |
5 | ||
Commu- nications functions |
Port | RS-232C (9-pin, D-Sub connector) | |
Communications method | Full duplex | ||
Synchronization method | Start/stop synchronization | ||
Transmission code | ASCII | ||
Baud rate | 38,400 (at shipping)/9,600 bps switchable | ||
Data bit length | 8 bits | ||
Parity check | None | ||
Stop bit length | 1 bit | ||
Data delimiter |
Receiving | CR or CR + LF is automatically recognized. | |
Sending | CR + LF fixed | ||
Indicators | Power supply: green, Sensor communications: green, Sensor communications error: red, External terminal communications: green, External terminal communications error: red |
||
Protective circuits | Power supply reverse polarity protection | ||
Ambient temperature | Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) |
||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max. |
||
Materials | Case: PBT (polybutylene terephthalate), Cover: Polycarbonate | ||
Accessories | Instruction sheet, 2 clamps |
Dimensions | Photoelectric Displacement Sensor – ZX2 series
(Unit: mm)
Tolerance class IT16 applies to dimensions in thes data sheet unless otherwise specified.
Units
Sensor Heads
ZX2-LD50
ZX2-LD50L
ZX2-LD100
ZX2-LD100L
ZX2-LD50V
* In the case of ZX2-LD50 (L), L=50, A=21 °
In the case of ZX2-LD100 (L), L=100, A=11.5 °
Note: Attach the enclosed ferrite core (16.5 dia., length: 30 mm) to the cable within 100 mm from the Sensor Head.
Amplifier Units
ZX2-LDA11
ZX2-LDA41
- Maximum height when cover open: 56
- Minimum length when connected: 50
Accessories (sold separately)
Calculating Unit
ZX2-CAL
Sensor Head Extension Cables
ZX2-XC1R
ZX2-XC4R
ZX2-XC9R
ZX2-XC20R
* Length L is as follows.
ZX2-XC1R: 1 m, ZX2-XC4R: 4 m, ZX2-XC9R: 9 m, ZX2-XC20R: 20 m
Minimum bending radius: 30 mm
Note: Attach the enclosed ferrite cores (16.5 dia., length: 30 mm) within 100 mm of each end of the extension cable.
ZX2-series Communications Interface Unit
ZX2-SF11
Mounting Bracket
E39-L178
Material: Stainless steel (SUS304)
Thickness: 3.0 mm
Accessories: Phillips screws (M3×30): 2, Nut plate: 1
Mounting Bracket
E39-L179
Material: Stainless steel (SUS304)
Thickness: 3.0 mm
Accessories: Phillips screws (M3×30): 2, Nut plate: 1
*Use this Mounting Bracket when installing the ZX2-LD100 (L) as a normal Diffuse-reflective or Regular-reflective Sensor Head.
Installation Method for Regular-reflective Sensor Head
Using a E39-L178 Mounting Bracket:
Note: When securing the Sensor Head in the Mounting Bracket, insert the screws into the side of the Sensor Head where
warning label is located and secure the Sensor Head into place.
- The measurement distance reference position is the end of the Mounting Bracket.
- For the Regulalr-reflective Sensor Heads, rotate the Sensor Head counterclockwise,secure it in place, and then perform any necessary fine adjustments.
Installation Method for Regular-reflective Sensor Heads
(Installing a Diffuse-reflective Sensor Head as a Regular-reflective Sensor Head)
Using a E39-L179 Mounting Bracket:
Note: When securing the Sensor Head in the Mounting Bracket, insert the screws into the side of the Sensor Head where
the warning label is located and secure the Sensor Head into place.
- The measurement distance reference position is the end of the Mounting Bracket.
- For the IInstalling a Diffuse-reflective Sensor as a Regular-reflective Sensor rotate the Sensor Head counterclockwise secure it in place, and then perform any necessary fine adjustments.
Not Using a Mounting Bracket:
Tilt the Sensor Head towards the workpiece as shown below.
Adjust the installation so that the angle is 10.5° ±0.1°.
* The mounting hole dimensions in parentheses (reference values) are for when the Sensor is installed at 10.5°.
Installation Method for Diffuse-reflective Sensor Heads
Using a E39-L178, E39-L179 Mounting Bracket:
- The measurement distance reference position is the Sensor’s sensing surface.
Note: When securing the Sensor Head in the Mounting Bracket, insert the screws into the side of the Sensor Head
where the warning label is located and secure the Sensor Head into place.
Not Using a Mounting Bracket:
Mount the Sensor Head in relation to the workpiece as shown below.
* ZX2-LD50 (L): 50
ZX2-LD100 (L): 100
คุณสมบัติ | Photoelectric Displacement Sensor – ZX2 series
- การวัดที่มีความแม่นยำสูงถึงประมาณ 10 ไมโครเมตร
- การวัดที่เสถียรโดยไม่คำนึงถึงการเคลื่อนไหวหรือการเปลี่ยนแปลงของสีหรือวัสดุของชิ้นงาน
- การปรับแต่งอย่างชาญฉลาดเพื่อการตั้งค่าที่ดีที่สุดด้วยปุ่มเดียวสำหรับผู้ใช้เป็นหลัก
- จอแสดงผล 11 ส่วนช่วยให้อ่านตัวอักษรได้อย่างรวดเร็ว
- การวัดที่เสถียรในสภาพแวดล้อมที่เลวร้ายด้วยการป้องกัน IP67 สำหรับหัวเซนเซอร์และสายหุ่นยนต์
- ตัวบ่งชี้อายุการใช้งานเลเซอร์เพื่อป้องกันการหยุดของกระบวนการผลิตผ่านการแสดงภาพ
คุณสมบัติ | Photoelectric Displacement Sensor – ZX2 series
Photoelectric Displacement Sensor | ZX2 |
---|---|
ระบบออปติก | สะท้อนแสงแบบกระจาย |
ช่วงการวัด | ±5 มม. |
รูปร่างลำแสง | เส้น, จุด |
ขนาดลำแสง | เส้นผ่านศูนย์กลาง ประมาณ 60 ไมโครเมตร |
ความละเอียด | 1.5 ไมโครเมตร |
ระดับการป้องกัน | IP67 |
วัสดุครอบคลุม | PBT (โพลีบิวทิลีนเทเรฟทาฮาเลต) |