OMRON Limit Switches – Z-X series
Model Numbers | Limit Switches – ZE / ZV / ZV2 / XE / XV / XV2 series
Actuator | Model | Approved standards |
Model | Approved standards |
Model | Approved standards |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
UL | CSA | UL | CSA | UL | CSA | |||||||
Mounting | Side mounting | Base mounting | Diagonal side mounting | |||||||||
General purpose |
Plunger | AC | ZE-Q-2 | ● | ● | ZV-Q-2 | ● | ● | ZV2-Q-2 | ● | ● | |
DC | XE-Q-2 | XV-Q-2 | XV2-Q-2 | |||||||||
Roller plunger |
AC | ZE-Q22-2 | ● | ● | ZV-Q22-2 | ● | ● | ZV2-Q22-2 | ● | ● | ||
DC | XE-Q22-2 | XV-Q22-2 | XV2-Q22-2 | |||||||||
Crossroller plunger |
AC | ZE-Q21-2 | ● | ● | ZV-Q21-2 | ● | ● | ZV2-Q21-2 | ● | ● | ||
DC | XE-Q21-2 | XV-Q21-2 | — | |||||||||
Roller arm lever |
AC | ZE-QA2-2 | ● | ● | ZV-QA2-2 | ● | ● | ZV2-QA2-2 | ● | ● | ||
DC | XE-QA2-2 | XV-QA2-2 | XV2-QA2-2 | |||||||||
One-way action roller arm lever |
AC | ZE-QA277-2 | ● | ● | — | ZV2-QA277-2 | ● | ● | ||||
DC | XE-QA277-2 | — | — | |||||||||
Sealed (Booted) |
Sealed plunger |
AC | ZE-N-2 | ● | ● | ZV-N-2 | ● | ● | ZV2-N-2 | ● | ● | |
DC | XE-N-2 | XV-N-2 | XV2-N-2 | |||||||||
Sealed roller plunger |
AC | ZE-N22-2 | ● | ● | ZV-N22-2 | ● | ● | ZV2-N22-2 | ● | ● | ||
Sealed crossroller plunger |
AC | ZE-N21-2 | ● | ● | ZV-N21-2 | ● | ● | ZV2-N21-2 | ● | ● | ||
Sealed roller arm lever |
AC | ZE-NA2-2 | ● | ● | ZV-NA2-2 | ● | ● | ZV2-NA2-2 | ● | ● | ||
DC | XE-NA2-2 | XV-NA2-2 | XV2-NA2-2 | |||||||||
One-way action sealed roller arm lever |
AC | ZE-NA277-2 | ● | ● | ZV-NA277-2 | ● | ● | ZV2-NA277-2 | ● | ● | ||
DC | XE-NA277-2 | – | – | — | – | – | – | – | – |
Note:The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
Note:Ask your OMRON representative for information on models with ground terminals.
Specifications | Limit Switches – ZE / ZV / ZV2 / XE / XV / XV2 series
Ratings
Model | Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | ||||||
NC | NO | NC | NO | NC | NO | NC | NO | ||
ZE-[] ZV-[] ZV2-[] |
125 VAC 250 VAC 480 VAC |
15 15 10 |
3 2.5 1.5 |
1.5 1.25 0.75 |
15 15 6 |
5 3 1.5 |
2.5 1.5 0.75 |
||
125 VDC 250 VDC |
0.5 0.25 |
0.5 0.25 |
0.05 0.03 |
0.05 0.03 |
|||||
XE-[] XV-[] XV2-[] |
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
10 10 10 10 3 |
3 3 3 3 1.5 |
1.5 1.5 1.5 1.5 0.75 |
10 10 10 7.5 2 |
10 10 10 6 1.5 |
5 5 5 2 2 |
2.5 2.5 2.5 2.5 1.5 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 15 A max. |
Note:The above figures are for standard currents.
Note:Inductive loads have a power factor of 0.4 min.(AC) and a time constant of 7 ms max. (DC).
Note:Lamp load has an inrush current of 10 times the steadystate current.
Note:Motor load has an inrush current of 6 times the steady-state current.
Characteristics
Degree of protection | IP65 *1 | |
---|---|---|
Durability *2 | Mechanical | Z[]: 10,000,000 operations min. X[]: 1,000,000 operations min. |
Electrical | Z[]: 500,000 operations min., for 15 A, 250 VAC resistive load X[]: 100,000 operations min., for 10 A, 125 VDC resistive load |
|
Operating speed | Plunger type: 0.01 mm/s to 0.5 m/s Lever type: 0.02 mm/s to 0.5 m/s |
|
Operating frequency | Mechanical | 120 operations/min |
Electrical | 20 operations/min | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value) | |
Terminal temperature rise | 50°C max. | |
Dielectric strength | Between terminals of the same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between current-carrying metal part and ground |
Z[]: 2,000 VAC, 50/60 Hz for 1 min X[]: 1,500 VAC, 50/60 Hz for 1 min |
|
Between each terminal and non-current-carrying metal part |
Z[]: 2,000 VAC, 50/60 Hz for 1 min X[]: 1,500 VAC, 50/60 Hz for 1 min |
|
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *3 |
Shock resistance*3 | Destruction | 1,000m/s2 max. |
Malfunction | 100 m/s2 max. *4 50 m/s2 max. *5 |
|
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | General-purpose type: 35% to 85%RH Sealed type: 35% to 95%RH |
|
Weight | Approx. 260 to 280 g |
Note:The above figures are initial values.
Note:IP65 for []-N models and IP60 for []-Q models.
Note:The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
Note:At the operation limit positions.
Note:Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
Note:Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.
Dimensions | Limit Switches – ZE / ZV / ZV2 / XE / XV / XV2 series
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
Roller Plunger
ZE-Q22-2
XE-Q22-2
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
One-way Action Roller Arm Lever
ZE-QA277-2
XE-QA277-2
Sealed Plunger
ZE-N-2
XE-N-2
Sealed Roller Plunger
ZE-N22-2
Sealed Crossroller Plunger
ZE-N21-2
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
One-way Action Sealed Roller Arm Lever
ZE-NA277-2
XE-NA277-2
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Base Mounting/Diagonal Side Mounting Models
The diagrams show the base-mounted model (ZV-[] or XV-[]) on top and the diagonal side-mounted model (ZV2-[] or XV2-[]) on bottom.
The flange on base-mounted models is shown with dotted lines.
Plunger
ZV(2)-Q-2
XV(2)-Q-2
Roller Plunger
ZV(2)-Q22-2
XV(2)-Q22-2
Crossroller Plunger
ZV(2)-Q21-2
XV-Q21-2
Roller Arm Lever
ZV(2)-QA2-2
XV(2)-QA2-2
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note: 1. OP for ZV2-Q-2 and XV2-Q-2 is 24.2 ±0.8 mm.
2. OP for ZV2-Q22-2 and XV2-Q22-2 is 35.7 ±1 mm.
3. OP for ZV2-Q21-2 is 35.7 ±0.8 mm.
One-way Action Roller Arm Lever
ZV2-QA277-2
Sealed Plunger
ZV(2)-N-2
XV(2)-N-2
Sealed Roller Plunger
ZV(2)-N22-2
Sealed Crossroller Plunger
ZV(2)-N21-2
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note: 1. OP for ZV2-N-2 and XV2-N-2 is 31.9 ±0.8 mm.
2. OP for ZV2-N22-2 is 35.7 ±0.8 mm.
3. OP for ZV2-N21-2 is 35.7 ±0.8 mm.
Sealed Roller Arm Lever
ZV(2)-NA2-2
XV(2)-NA2-2
One-way Action Sealed Roller Arm Lever
ZV(2)-NA277-2
XV2-NA277-2
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
last update: March 03, 2014
Features | Limit Switches – ZE / ZV / ZV2 / XE / XV / XV2 series
High life limit switches and high braking power
- Basic switch Z model, which is included in the ZE ZV ZV2, has high braking strength.
- A small magnet X-style basic switch was added to the XE XV XV2.
- 3 mounting patterns (side, base and diagonal)
- Can be easily installed
- Grounded
Properties | Limit Switches – ZE / ZV / ZV2 / XE / XV / XV2 series
Limit Switches | ZE / ZV / ZV2 / XE / XV / XV2 | |
---|---|---|
Switching standard loads | 15A | 250 VAC |
10A | 30 VDC | |
Life expectancy | 10,000,000 operations min. |