OMRON Safety Door Switches – D4NS / D4NS-SK series
Model Numbers | Safety Door Switches – D4NS / D4NS-SK series
Switches (Operation Keys are sold separately.)
Models with certified direct opening contacts.
Consult with your OMRON representative when ordering any models that are not listed in this table.
Type | Contact configuration | Conduit outlet / Connector | Model | |
---|---|---|---|---|
1-Conduit type | Slow-action | 1NC/1NO | Pg13.5 | D4NS-1AF * |
G1/2 | D4NS-2AF * | |||
M20 | D4NS-4AF | |||
2NC | Pg13.5 | D4NS-1BF * | ||
G1/2 | D4NS-2BF * | |||
M20 | D4NS-4BF | |||
2NC/1NO | Pg13.5 | D4NS-1CF * | ||
G1/2 | D4NS-2CF * | |||
M20 | D4NS-4CF | |||
3NC | Pg13.5 | D4NS-1DF * | ||
G1/2 | D4NS-2DF * | |||
M20 | D4NS-4DF | |||
Slow-action MBB contact | 1NC/1NO | Pg13.5 | D4NS-1EF | |
G1/2 | D4NS-2EF | |||
M20 | D4NS-4EF | |||
2NC/1NO | Pg13.5 | D4NS-1FF | ||
G1/2 | D4NS-2FF | |||
M20 | D4NS-4FF | |||
2-Conduit type | Slow-action | 1NC/1NO | G1/2 | D4NS-6AF |
M20 | D4NS-8AF | |||
2NC | G1/2 | D4NS-6BF | ||
M20 | D4NS-8BF | |||
2NC/1NO | G1/2 | D4NS-6CF | ||
M20 | D4NS-8CF | |||
3NC | G1/2 | D4NS-6DF | ||
M20 | D4NS-8DF | |||
Slow-action MBB contact | 1NC/1NO | G1/2 | D4NS-6EF | |
M20 | D4NS-8EF | |||
2NC/1NO | G1/2 | D4NS-6FF | ||
M20 | D4NS-8FF | |||
1-Conduit type, with connector | Slow-action | 1NC/1NO | M12 connector | D4NS-9AF |
2NC | D4NS-9BF | |||
Slow-action MBB contact | 1NC/1NO | D4NS-9EF | ||
1-Conduit type (High pull-force type) |
Slow-action | 1NC/1NO | G1/2 | D4NS-2AF-SJ * |
M20 | D4NS-4AF-SJ * | |||
2NC | G1/2 | D4NS-2BF-SJ * | ||
M20 | D4NS-4BF-SJ * | |||
2NC/1NO | G1/2 | D4NS-2CF-SJ * | ||
M20 | D4NS-4CF-SJ * | |||
3NC | G1/2 | D4NS-2DF-SJ * | ||
M20 | D4NS-4DF-SJ * |
* Models with Korean S-mark certification.
Operation Keys
Type | Model | |
---|---|---|
Horizontal mounting | D4DS-K1 | |
Vertical mounting | D4DS-K2 | |
Adjustable mounting (Horizontal) | D4DS-K3 | |
Adjustable mounting (Horizontal/Vertical) | D4DS-K5 |
Slide Keys
Appearance | Specifications | Contents | Model | Applicable Door Switch |
---|---|---|---|---|
Weight: 422 g Mechanical durability: 20,000 operations min. |
Slide Key (Operation Key included.): 1 Auxiliary mounting bracket: 1 Receptacle bracket: 1 |
D4NS-SK01 | D4NS 1-conduit type |
|
Weight: 2,800 g Mechanical durability: 20,000 operations min. |
Slide Key: 1 (Disable-prevention cover and Operation Key D4DS-K2 are already mounted on Slide Key) D4NS mounting tool: 1 Inner lever: 1 Inner lever mounting screws: 2 Door Switch mounting one-way screws: 2 Switch protective cover: 1 Switch protective cover screws: 4 |
D4NS-SK30 | D4NS 1-conduit type |
Specifications | Safety Door Switches – D4NS / D4NS-SK series
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60947-5-1
• EN ISO 14119
• GS-ET-15
Certified Standards
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) |
Consult your OMRON representative for details. |
UL *1 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) | GB/T 14048.5 | Consult your OMRON representative for details. |
KOSHA *2 | EN60947-5-1 | Consult your OMRON representative for details. |
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB/T 14048.5)
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 10 A | 60 | 6 | 7,200 | 720 |
240 VAC | 30 | 3 |
Q300
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
125 VDC | 2.5 A | 0.55 | 0.55 | 69 | 69 |
250 VDC | 0.27 | 0.27 |
Characteristics
Interlock type | Type 2 (EN ISO 14119) | |
---|---|---|
Coding level | Low level coded (EN ISO 14119) | |
Degree of protection *1 | IP67 (EN60947-5-1) | |
Durability *2 | Mechanical | Standard type: 1,000,000 operations min. High pull-force type: 100,000 operations min. |
Electrical | Standard type: 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) High pull-force type: 100,000 operations min. (10 A resistive load at 250 VAC) |
|
Operating speed | 0.05 to 0.5 m/s | |
Direct opening force *4 | Standard type: 60 N min. High pull-force type: 80 N min. |
|
Direct opening travel *4 | 10 mm min. | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *5 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 300 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) |
3 (EN60947-5-1) | |
Impulse withstand voltage (Uimp) (EN60947-5-1) |
Between terminals of same polarity |
2.5 kV |
Between terminals of different polarity |
4 kV | |
Between each terminal and non-current carrying metallic parts |
6 kV | |
Insulation resistance | 100 MΩ min. | |
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 96 g (D4NS-1CF) |
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to
switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough
once they have been used and contact reliability for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
protected from dust or water penetration, do not use the D4NS in places where foreign material may enter through the
key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details,
consult your OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is
possible with the actual load beforehand.
Dimensions | Safety Door Switches – D4NS / D4NS-SK series
(Unit: mm)
1-Conduit Types
D4NS-1[]F
D4NS-2[]F
D4NS-4[]F
D4NS-2[]F-SJ
D4NS-4[]F-SJ
2-Conduit Types
D4NS-6[]F
D4NS-8[]F
1-Conduit Connector Types
D4NS-9[]F
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC).
Confirm performance before application.
Operation Keys
D4DS-K1
D4DS-K2
D4DS-K3
D4DS-K5
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Slide Keys
D4NS-SK01
Main Body
Auxiliary Mounting Bracket and Receptacle Bracket
Switch Mounting Pattern 1
Switch Mounting Pattern 2
D4NS-SK30
Open Door
Closed Door
With Operation Key Inserted (Relationship between Insertion Radius and Key Hole)
D4NS-1[]F + D4DS-K1
(with Front-inserted Operation Key)
D4NS-1[]F + D4DS-K1
(with Top-inserted Operation Key)
D4NS-1[]F + D4DS-K2
(with Front-inserted Operation Key)
D4NS-1[]F + D4DS-K2
(with Top-inserted Operation Key)
D4NS-1[]F + D4DS-K3
(with Front-inserted Operation Key)
D4NS-1[]F + D4DS-K3
(with Top-inserted Operation Key)
D4NS-1[]F + D4DS-K5
(with Front-inserted Operation Key)
D4NS-1[]F + D4DS-K5
(with Top-inserted Operation Key)
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* Insertion radii apply when the rotational center of the Operation Key is in line with a line extending from the front or top Head surface.
Features | Safety Door Switches – D4NS / D4NS-SK series
- Multi-contact, environment-friendly, next-generation safety-door switch
- Lineup three contact models with 2NC/1NO and 3NC contact forms and MBB models 1NC/1NO, and 2NC
Properties | Safety Door Switches – D4NS / D4NS-SK series
Safety Door Switches | D4NS | D4NS-SK |
---|---|---|
Type | แบบ Standard / High pull-force | |
Direct opening force | 60 / 80 นิวตัน | |
Max Actuation Frequency | 30 operations / min | |
Max Actuation Speed:500 mm / s | 500 mm /s | |
Weight | 96 g | |
Built-in Switch | 1 NO/1 NC , 2 NC , 2 NC/1 NO , 3 NC ( Slow-action ) | |
1 NC/1 NO , 2 NC/1 NO ( MBB contact ) | ||
IP | 67 | |
Option | – | Replacement Contact Block |
– | Micro Style Cables | |
– | Cabling Components | |
– | Conduit LED Beacons | |
– | Security Bits / Devices |