Hiwin Positioning Measurement – Scale
- Compatible with various measurement in struments to achieve different accuracy requirements.
- Magnetic scale can main tain performance under severe ambient conditions caused by oil, water or dust to gain required accuracy and signal feedback.
Positioning Measurement – Scale
Code | Positioning Measurement – Scale
Specifications | Positioning Measurement – Scale
Pole pitch
1mm
5mm
Accuracy@20°C
±20 µ m/m
±(80+15xL) µm
(L : Length (Unit : m))
Width
10 mm (0 mm ~ ±0.2 mm)
Thickness
1.9 mm (±0.1 mm)
Maximum scale length
24 mm
30 mm
Coefficient of linear thermal expansion
(11±1) x 10-6 m/k
Working temperature
0 – 50 °C
Storage temperature
-5 ~ 70 °C
Protection class
IP67
Dimensions | Positioning Measurement – Scale