Hiwin Positioning Measurement System Enclosed
Positioning Measurement – Enclosed
Feature | Positioning Measurement – Enclosed
Code| Positioning Measurement – Enclosed
Specifications | Positioning Measurement – Enclosed
Measuring Length
(ML, unit:mm)50, 100, 150, 200
250, 300, 350, 400, 450, 500, 550, 600, 650, 750, 850, 950, 1050
Maximum trave (Unit: mm)
ML+104
ML+120
Overal length (Unit: mm)
ML+12
ML+28
Accuracy@20°C
(5+5ML/1000) µ m
Within Mwasuring Length is 30 µ m
Resolution
1µm
Signal format
Digital
Output signal
5V TTL/RS422
Reference point
Standard: Center point/Edge(at 25 mm away from edge of ML)
User-selected point
Maximum travel speed
1.2/sec
Mounting parallelism
±0.1 mm
Input voltage
5VDC±5%/0.23A
Coefficient of linear thermal expansion
(11.8±0.6)x10-6 m/K
Operating temperature
0 – 50 °C
Storage temperature
-20 – 60 °C
Protection
Readhead: IP67
Translator: IP30
Vibration resistance
(50 – 2000 Hz)150 m/S2 (EN60068-2-6)
Impact resistance (11 ms)
1000 m/S2 (EN60068-2-27)
Dimensions | Positioning Measurement – Enclosed