Hiwin Positioning Measurement – Vertical Type
- Didital or analog signal output availble / Avaliable gap up to 4 mm.
- Vertical shape, optimal for space-saving applications.
- Optional metal protection tube.
- Resolution up to 1 µm / Repeatability up to ±2 µm.
Positioning Measurement – Vertical Type
Code | Positioning Measurement – Vertical Type

Specifications | Positioning Measurement – Vertical Type
Pole pitch | 1mm | 5mm | ||
---|---|---|---|---|
Available gap(1) | 0.4mm | 4mm | ||
Signal format | Analogue | Digital | Digital | |
Output signal | SIN/COS 1Vp-p | 5V TTL/RS422 | 5V TTL/RS422 | 24V/PP |
Resolution(3) | 1mm | 1µm | 5µm | 5µm |
Repeatability(2) | ±3µm | ±2µm | ±10µm | ±10µm |
Reference signal | 2mm/pulse | 1mm/pulse | 5 mm/pulse | |
Maximum travel speed | 10 m/sec | 5 m/sec | 5 m/sec | 8 m/sec |
Input voltage | 5VDC±5% | 24VDC±10% | ||
Operating temperature | 0 ~ 50 °C | |||
Storage temperature | -5 ~ 70 °C | |||
Protectopm class | IP67 |
- Note
- Please refer Chap 5.7 for Gap-Repeatability relationship.
- The data were measured while gap is 0.1 mm.
- If you have ohter request on resolution, please do not hesitate to contact us.
Dimensions | Positioning Measurement – Vertical Type

ติดต่อ Hiwin, Linear Motion, Automation, Robot, System Intregration