The HIWIN LMTD series: LMTE = Diameter of stator = 50mm, Peak = 1284N – 2569N, Continuous = 321N – 642N The HIWIN rod-shaped linear motor has a variety of size series, with complete specifications, and easy installation. The maximum peak force for this motor is up to about 2570N. It complies with international safety CE certification, has dustproof and a waterprood IP66 rating. Using direct drive technology, on other mechanical conversion components arr needed to acieve linear tranmission, with high-speed, no cogging and low velocity ripple along with other characteristics including; excellent dynamic performance, no wear, zero backlash, and easy maintenance. Compared to traditional mechanical linear solutions, the motor effectively enhances machine equipment production capacity and reduces maintenance costs to meet the needs of high-precision positioning control and smooth operation applications such as high-speed light-load automation equipment, dust-free environment, automation equipment, panel equipment, optical inspection equipment, tool line cutting equipment, scanning electron microscope equipment, medical automation and other industries.
Hiwin Shaft Motors – LMTE series
Linear Shaft Motors – LMTE series
Feature | Shaft Motors – LMTE series
Force Chart | Shaft Motors – LMTE series
Code | Shaft Motors – LMTE series
Specifications | Shaft Motors – LMTE series
Detail
Symbol
Unit
LMTE2
LMTE3
LMTE4
Continuous force
Fc
N
321
480
642
Continuous current
Ic
Arms
7.7
11.5
15.4
Peak force (1s)
Fp
N
1284
1918
2569
Peak current (1s)
Ip
Arms
30.8
46.0
61.6
Force constant
Kf
N/Arms
41.7
Electrical time constant
Ke
ms
6.5
Resistance (line to line 25°C)
R25
Ω
1.8
1.2
0.9
Inductance (line to line)
L
mH
12
8
6
Pole pair pitch
2T
mm
180
Back emf constant (line to line)
Kv
Vrms/(m/s)
24.4
Motor constant (25°C)
Km
N/√W
25.1
30.7
35.5
Thermal resistance
RTH
°C/W
0.4
0.3
0.5
Thermal switch
–
–
PTC
Maximum DC bus voltage
–
VDC
325
Mass of forcer
Mf
kg
7.8
11.3
14.7
Unit mass of stator
Ms
kg/m
13.5
Length of forcer
Lf
mm
210
300
390
Mounting pitch
P1 x P2
mm
90 x 90
Stroke
S
mm
100 ~ 1000 (Take 50 mm as increase unit)
Clamping length
L1
mm
100 (Stroke = 1000 ~ 2000 mm)
Total stator length
Ls
mm
Ls (Total stator length) = S (Stroke) + Lf (Length of forcer) + 2*L1 (Clamping legnth)
Hiwin Shaft Motors – LMTE series
Feature | Shaft Motors – LMTE series
- Excellent dynamic characteristics : no cogging
- Low velocity ripple
- Max. Acceleration up to 5G
- CE certification
- Ingress Protection rating : IP66
- No wear, zero backlash
- Similar to screw mechanism, easy to install