OMRON Emergency Stop Switches – A22NE-PD / A22NE-P / A22E series
Model Numbers | Emergency Stop Switches – A22NE-PD / A22NE-P / A22E series
A22NE-PD Push-in Plus Terminal Block Models
Model Number Structure
Model Number Legend (Completely Assembled)
Shipped as a set which includes the Operation Unit, LED Lamp (lighted models only), and Switch Block.
Ordering Information
List of Models (Completely Assembled)
Non-lighted Models (Without EMO/EMS Indication)
Appearance | Operation | Degree of Protection |
Contact configuration * |
Set Model | Color of cap |
---|---|---|---|---|---|
40-dia. head Medium Pull-reset A22NE-MP-PD[][]-N |
IP65 oil-resistant models |
2NC | A22NE-MP-PD02-N | Red | |
2NC, 1NO | A22NE-MP-PD12-N | ||||
3NC | A22NE-MP-PD03-N | ||||
2NC, 2NO | A22NE-MP-PD22-N | ||||
3NC, 1NO | A22NE-MP-PD13-N | ||||
4NC | A22NE-MP-PD04-N | ||||
40-dia. head Medium Pull-reset A22NE-MP-PD[][]-N-69K |
IP69K | 2NC | A22NE-MP-PD02-N-69K | ||
2NC, 1NO | A22NE-MP-PD12-N-69K | ||||
3NC | A22NE-MP-PD03-N-69K | ||||
2NC, 2NO | A22NE-MP-PD22-N-69K | ||||
3NC, 1NO | A22NE-MP-PD13-N-69K | ||||
4NC | A22NE-MP-PD04-N-69K | ||||
30-dia. head Small Turn-reset A22NE-S-PD[][]-N |
IP65 oil-resistant models |
2NC | A22NE-S-PD02-N | ||
2NC, 1NO | A22NE-S-PD12-N | ||||
3NC | A22NE-S-PD03-N | ||||
2NC, 2NO | A22NE-S-PD22-N | ||||
3NC, 1NO | A22NE-S-PD13-N | ||||
4NC | A22NE-S-PD04-N | ||||
40-dia. head Medium Turn-reset A22NE-M-PD[][]-N |
IP65 oil-resistant models |
2NC | A22NE-M-PD02-N | ||
2NC, 1NO | A22NE-M-PD12-N | ||||
3NC | A22NE-M-PD03-N | ||||
2NC, 2NO | A22NE-M-PD22-N | ||||
3NC, 1NO | A22NE-M-PD13-N | ||||
4NC | A22NE-M-PD04-N | ||||
60-dia. head Large Turn-reset A22NE-L-PD[][]-N |
IP65 oil-resistant models |
2NC | A22NE-L-PD02-N | ||
2NC, 1NO | A22NE-L-PD12-N | ||||
3NC | A22NE-L-PD03-N | ||||
2NC, 2NO | A22NE-L-PD22-N | ||||
3NC, 1NO | A22NE-L-PD13-N | ||||
4NC | A22NE-L-PD04-N |
* In addition to the above, we also provide the following contact configurations: [1NC], [1NC, 1NO], and [1NC, 2NO]. Ask your OMRON representative for details.
Lighted Model (Without EMO/EMS Indication)
Appearance | Operation | Degree of Protection |
Contact configuration * |
LED Lamp voltage |
Set Model | Color of cap |
---|---|---|---|---|---|---|
40-dia. head Medium Turn-reset A22NE-M-PD[][]-C |
IP65 | 2NC | 24 V AC/DC | A22NE-M-PD02-C | Red | |
2NC, 1NO | A22NE-M-PD12-C | |||||
3NC | A22NE-M-PD03-C | |||||
2NC, 2NO | A22NE-M-PD22-C | |||||
3NC, 1NO | A22NE-M-PD13-C | |||||
4NC | A22NE-M-PD04-C |
* In addition to the above, we also provide the following contact configurations: [1NC], [1NC, 1NO], and [1NC, 2NO]. Ask your OMRON representative for details.
Accessories (Order Separately)
Operation Unit
Non-lighted
Size | Small (30 dia.) | Medium (40 dia.) | Large (60 dia.) | |
---|---|---|---|---|
Function | Degree of Protection | Single item order model | ||
Pull-reset | IP65 oil-resistant models |
— | A22NE-MP-N |
— |
IP69K | — | A22NE-MP-N-69K |
— | |
Turn-reset | IP65 oil-resistant models |
A22NE-S-N |
A22NE-M-N |
A22NE-L-N |
A22NE-MRO-N A22NE-MRO-N-RD |
||||
A22NE-MRS-N A22NE-MRS-N-RD |
Lighted
Size | Medium (40 dia.) | |
---|---|---|
Function | Sealing capability | Single item order model |
Turn-reset | IP65 | A22NE-M-L |
LED lamp
Appearance | LED light | Rated voltage | Model | Remarks |
---|---|---|---|---|
Red | 24 VAC/VDC | A22NZ-L-RC | These are provided with the completely assembled set of lighted models. Order LED Lamps only when replacing them. |
Control Box
Item | Appearance | Model | Remarks | |
---|---|---|---|---|
Control Box | One hole, yellow box | A22NZ-A-B101Y | Material: Polycarbonate resin. For 22.3-mm panel hole diameter. |
Note: For details on the accessories common to the screw terminal block models and push-in plus terminal block models, refer to “Common Accessories and Tools (Order Separately)” .
A22NE-P Push-in Plus Terminal Block Models
Model Number Structure
Model Number Legend (Completely Assembled)
Shipped as a set which includes the Operation Unit, LED Lamp (lighted model only), Mounting Latches, Lighting Units (lighted model only), and Switch Block.
Ordering Information
List of Models (Completely Assembled)
Non-lighted Models
Appearance | Operation | Degree of Protection |
Contact configuration * |
Set Model | Color of cap |
---|---|---|---|---|---|
40-dia. head Medium Pull-reset A22NE-MP-P[][]2-N |
IP65 oil-resistant models |
1NC (1) | A22NE-MP-P002-N | Red | |
1NC, 1NO (2) | A22NE-MP-P102-N | ||||
2NC (2) | A22NE-MP-P202-N | ||||
2NC, 1NO (3) | A22NE-MP-P212-N | ||||
3NC (3) | A22NE-MP-P222-N | ||||
40-dia. head Medium Pull-reset A22NE-MP-P[][]2-N-69K |
IP69K | 1NC (1) | A22NE-MP-P002-N-69K | ||
1NC, 1NO (2) | A22NE-MP-P102-N-69K | ||||
2NC (2) | A22NE-MP-P202-N-69K | ||||
2NC, 1NO (3) | A22NE-MP-P212-N-69K | ||||
3NC (3) | A22NE-MP-P222-N-69K | ||||
30-dia. head Small Turn-reset A22NE-S-P[][]2-N |
IP65 oil-resistant models |
1NC (1) | A22NE-S-P002-N | ||
1NC, 1NO (2) | A22NE-S-P102-N | ||||
2NC (2) | A22NE-S-P202-N | ||||
2NC, 1NO (3) | A22NE-S-P212-N | ||||
3NC (3) | A22NE-S-P222-N | ||||
40-dia. head Medium Turn-reset A22NE-M-P[][]2-N |
1NC (1) | A22NE-M-P002-N | |||
1NC, 1NO (2) | A22NE-M-P102-N | ||||
2NC (2) | A22NE-M-P202-N | ||||
2NC, 1NO (3) | A22NE-M-P212-N | ||||
3NC (3) | A22NE-M-P222-N | ||||
60-dia. Large Turn-reset A22NE-L-P[][]2-N |
1NC (1) | A22NE-L-P002-N | |||
1NC, 1NO (2) | A22NE-L-P102-N | ||||
2NC (2) | A22NE-L-P202-N | ||||
2NC, 1NO (3) | A22NE-L-P212-N | ||||
3NC (3) | A22NE-L-P222-N |
* The number in parentheses ( ) indicates the number of switch units.
Lighted Model
Appearance | Operation | Degree of Protection |
Contact configuration * |
LED Lamp voltage |
Set Model | Color of cap |
---|---|---|---|---|---|---|
40-dia. head Medium Turn-reset A22NE-M-P[][]2-A |
IP65 | 1NC (1) | 6 VAC/VDC | A22NE-M-P002-A | Red | |
1NC, 1NO (2) | A22NE-M-P102-A | |||||
2NC (2) | A22NE-M-P202-A | |||||
40-dia. head Medium Turn-reset A22NE-M-P[][]2-B |
1NC (1) | 12 VAC/VDC | A22NE-M-P002-B | |||
1NC, 1NO (2) | A22NE-M-P102-B | |||||
2NC (2) | A22NE-M-P202-B | |||||
40-dia. head Medium Turn-reset A22NE-M-P[][]2-C |
1NC (1) | 24 VAC/VDC | A22NE-M-P002-C | |||
1NC, 1NO (2) | A22NE-M-P102-C | |||||
2NC (2) | A22NE-M-P202-C | |||||
40-dia. head Medium Turn-reset A22NE-M-P[][]2-D |
1NC (1) | 100, 110, 120 VAC |
A22NE-M-P002-D | |||
1NC, 1NO (2) | A22NE-M-P102-D | |||||
2NC (2) | A22NE-M-P202-D | |||||
40-dia. head Medium Turn-reset A22NE-M-P[][]2-E |
1NC (1) | 220, 230, 240 VAC |
A22NE-M-P002-E | |||
1NC, 1NO (2) | A22NE-M-P102-E | |||||
2NC (2) | A22NE-M-P202-E |
* The number in parentheses ( ) indicates the number of switch units.
Switch with Integrated Control Box
Appearance | Contact configuration (Number of switch blocks) |
Model |
---|---|---|
1NC (1) | A22NE-M-P002-N-B | |
1NC, 1NO (2) | A22NE-M-P102-N-B | |
2NC (2) | A22NE-M-P202-N-B |
Subassembled
The Operation Unit, LED Lamp, Mounting Latches, Switch Blocks, and Lighting Unit can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts.
Operation Unit
Non-lighted
Size | Small (30 dia.) | Medium (40 dia.) | Large (60 dia.) | |
---|---|---|---|---|
Function | Sealing capability | Single item order model | ||
Pull-reset | IP65 oil-resistant models |
— | A22NE-MP-N |
— |
IP69K | — | A22NE-MP-N-69K |
— | |
Turn-reset | IP65 oil-resistant models |
A22NE-S-N |
A22NE-M-N |
A22NE-L-N |
A22NE-MRO-N A22NE-MRO-N-RD |
||||
A22NE-MRS-N A22NE-MRS-N-RD |
Lighted
Size | Medium (40 dia.) | |
---|---|---|
Function | Sealing capability | Single item order model |
Turn-reset | IP65 | A22NE-M-L |
LED lamp
Appearance | LED light | Rated voltage | Model | Remarks |
---|---|---|---|---|
Red | 6 VAC/VDC | A22NZ-L-RA | These LED lamps are for exclusive use with the A22N and the A22NE-P. These are provided with the completely assembled set of lighted models. Order LED lamps only when replacing them. |
|
12 VAC/VDC | A22NZ-L-RB | |||
24 VAC/VDC | A22NZ-L-RC | |||
100, 110, 120 VAC | A22NZ-L-RD | |||
200, 220, 230, 240 VAC | A22NZ-L-RE |
Accessories (Order Separately)
Item | Appearance | Contact specifications | Model | Remarks | |
---|---|---|---|---|---|
Switch Blocks (one contact) |
1NO (Blue) | Standard load | A22NZ-S-P1AN | Provided as standard. Order Switch Blocks only when adding or replacing them. |
|
1NC (Red) | Standard load | A22NZ-S-P1BN | |||
Switch Blocks (two contacts) |
2NC (Red) | Standard load | A22NZ-S-P2BN | Order Switch Blocks only when adding or replacing them. |
|
1NO/1NC (White) |
Standard load | A22NZ-S-P2CN | |||
Lighting unit | 6 VAC/VDC | A22NZ-T-APN | These are provided with the completely assembled set of lighted models. Order Lighting Units only when replacing them. |
||
12 VAC/VDC | A22NZ-T-BPN | ||||
24 VAC/VDC | A22NZ-T-CPN | ||||
100, 110, 120 VAC | A22NZ-T-DPN | ||||
200, 220, 230, 240 VAC | A22NZ-T-EPN | ||||
Mounting Latches |
— | A22NZ-H-02 | This Mounting Latch is for exclusive use with the A22NE-P. It is provided with the completely assembled set. Order Mounting Latches only when mounting Switch Blocks or Lighting Units that are purchased individually. |
||
Control Boxes (Enclosures) |
One hole, yellow box | A22NZ-A-B101Y | Can be combined with 2-contact Switch Blocks. |
||
A22NZ-A-B01Y | Cannot be combined with 2-contact Switch Blocks. * |
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to “Common Accessories and Tools (Order Separately)” on below.
* The A22NZ-A-B01Y Control Box cannot be used in combination with the A22Z-3476-1 90-dia. Legend Plates for Emergency Stop or the A22Z-EG[]E-stop Shrouds.
A22E Screw Terminal Block types
Model Number Structure
Model Number Legend (Completely Assembled)
Shipped as a set which includes the Operation Unit, LED Lamp (lighted model only), Mounting Latches, Switch Block, and Lock Plate
Ordering Information
List of Models (Completely Assembled)
Non-lighted Models (Without EMO/EMS Indication)
Appearance | Operation | Degree of Protection |
Contact configuration *1 |
Set Model | Color of cap |
---|---|---|---|---|---|
40-dia. head Medium Pull-reset A22E-MP |
IP65 oil-resistant models |
1NC (1) | A22E-MP-01 | Red | |
1NC, 1NO (2) | A22E-MP-11 | ||||
2NC (2) | A22E-MP-02 | ||||
30-dia. head Small Turn-reset A22E-S |
1NC (1) | A22E-S-01 *2 | |||
1NC, 1NO (2) | A22E-S-11 *2 | ||||
2NC (2) | A22E-S-02 *2 | ||||
2NC, 1NO (3) | A22E-S-12 *2 | ||||
3NC (3) | A22E-S-03 *2 | ||||
40-dia. head Medium Turn-reset A22E-M |
1NC (1) | A22E-M-01 *2 | |||
1NC, 1NO (2) | A22E-M-11 *2 | ||||
2NC (2) | A22E-M-02 *2 | ||||
2NC, 1NO (3) | A22E-M-12 *2 | ||||
3NC (3) | A22E-M-03 *2 | ||||
60-dia. Large Turn-reset A22E-L |
1NC (1) | A22E-L-01 *2 | |||
1NC, 1NO (2) | A22E-L-11 *2 | ||||
2NC (2) | A22E-L-02 *2 |
*1. The number in parentheses ( ) indicates the number of switch units.
*2. Models with Korean S-mark certification
Note: Yellow cap models are also available (not for emergency stop use). Contact your OMRON representative.
Non-lighted Models (With EMO/EMS Indication)
Appearance | Operation | Degree of Protection |
Contact configuration *1 |
Set Model | Color of cap |
---|---|---|---|---|---|
40-dia. head Medium Turn-reset With EMO Indication |
IP65 oil-resistant models |
1NC (1) | A22E-M-01-EMO *2 | Red | |
A22E-M-01-EMO-RD | |||||
1NC, 1NO (2) | A22E-M-11-EMO *2 | ||||
A22E-M-11-EMO-RD | |||||
2NC (2) | A22E-M-02-EMO *2 | ||||
A22E-M-02-EMO-RD | |||||
2NC, 1NO (3) | A22E-M-12-EMO *2 | ||||
A22E-M-12-EMO-RD | |||||
3NC (3) | A22E-M-03-EMO *2 | ||||
A22E-M-03-EMO-RD | |||||
40-dia. head Medium Turn-reset With EMS Indication |
1NC (1) | A22E-M-01-EMS *2 | |||
A22E-M-01-EMS-RD | |||||
1NC, 1NO (2) | A22E-M-11-EMS *2 | ||||
A22E-M-11-EMS-RD | |||||
2NC (2) | A22E-M-02-EMS *2 | ||||
A22E-M-02-EMS-RD | |||||
2NC, 1NO (3) | A22E-M-12-EMS *2 | ||||
A22E-M-12-EMS-RD | |||||
3NC (3) | A22E-M-03-EMS *2 | ||||
A22E-M-03-EMS-RD |
*1. The number in parentheses ( ) indicates the number of switch units.
*2. Models with Korean S-mark certification
Note: The colors of switch blocks are as follows:
NO (a-contact): Black
NC (b-contact): Red
The above illustration shows the 2NC (2b-contact) configuration.
Lighted Models
Appearance | Operation | Degree of Protection |
Contact configuration *1 |
LED Lamp voltage |
Set Model | Color of cap |
---|---|---|---|---|---|---|
40-dia. head Push-lock Turn-reset Lighting unit (Direct lighting) A22E |
IP65 | 1NC (1) | 6 VAC/VDC | A22EL-M-6A-01 *2 | Red | |
12 VAC/VDC | A22EL-M-12A-01 *2 | |||||
24 VAC/VDC | A22EL-M-24A-01 *2 | |||||
1NC, 1NO (2) | 6 VAC/VDC | A22EL-M-6A-11 *2 | ||||
12 VAC/VDC | A22EL-M-12A-11 *2 | |||||
24 VAC/VDC | A22EL-M-24A-11 *2 | |||||
2NC (2) | 6 VAC/VDC | A22EL-M-6A-02 *2 | ||||
12 VAC/VDC | A22EL-M-12A-02 *2 | |||||
24 VAC/VDC | A22EL-M-24A-02 *2 | |||||
40-dia. head Push-lock Turn-reset Lighting unit (Voltage-reduction lighting) A22E |
1NC (1) | 100 VAC | A22EL-M-T1-01 | |||
200 VAC | A22EL-M-T2-01 | |||||
1NC, 1NO (2) | 100 VAC | A22EL-M-T1-11 | ||||
200 VAC | A22EL-M-T2-11 | |||||
2NC (2) | 100 VAC | A22EL-M-T1-02 | ||||
200 VAC | A22EL-M-T2-02 |
*1. The number in parentheses ( ) indicates the number of switch units.
*2. Models with Korean S-mark certification
Switch with Integrated Control Box
Appearance | Contact configuration (Number of switch blocks) |
Model |
---|---|---|
1NC (1) | A22E-M-01B * | |
1NC, 1NO (2) | A22E-M-11B * | |
2NC (2) | A22E-M-02B * |
Note: The A22Z-B101Y Control Box is used.
* Models with Korean S-mark certification
Subassembled
The Operation Unit, LED Lamp, Mounting Latches, and Switch Blocks can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts.
Operation Unit
Non-lighted
Size | Small (30 dia.) | Medium (40 dia.) | Large (60 dia.) | |
---|---|---|---|---|
Function | Sealing capability | Single item order model | ||
Pull-reset | IP65 oil-resistant models |
— | A22E-MP |
— |
Turn-reset | A22E-S |
A22E-M |
A22E-L |
|
A22E-M-EMO A22E-M-EMO-RD |
||||
A22E-M-EMS A22E-M-EMS-RD |
Lighted
Size | Medium (40 dia.) | |
---|---|---|
Function | Sealing capability | Single item order model |
Turn-reset | IP65 | A22EL-M |
LED lamp
Appearance | LED light | Rated voltage | Model | |
---|---|---|---|---|
Red | Standard | 6 VAC/VDC | A22-6AR | |
12 VAC/VDC | A22-12AR | |||
24 VAC/VDC | A22-24AR |
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
Switch
Non-lighted / Direct lighting
Classification | Non-lighted | Direct lighting | |
---|---|---|---|
Appearance | |||
Contact specifications/ Configuration (Number of switch blocks) |
Model | Model | |
For Standard loads | 1NC (1) | A22-01M | A22L-01M |
1NC, 1NO (2) | A22-11M | A22L-11M | |
2NC (2) | A22-02M | A22L-02M |
Voltage-reduction lighting (100 VAC, 200 VAC)
Classification | 100 VAC, Lighted | 200 VAC, Lighted | |
---|---|---|---|
Appearance | |||
Contact specifications/ Configuration (Number of switch blocks) |
Model | Model | |
For Standard loads | 1NC (1) | A22L-01M-T1 | A22L-01M-T2 |
1NC, 1NO (2) | A22L-11M-T1 | A22L-11M-T2 | |
2NC (2) | A22L-02M-T1 | A22L-02M-T2 |
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
Accessories (Order Separately)
Item | Appearance | Contact specifications | Model | Remarks | |
---|---|---|---|---|---|
Switch Blocks (one contact) |
1NO (Black) | Standard load | A22-10 | Provided as standard. Order Switch Blocks only when adding or replacing them. |
|
Microload | A22-10S | ||||
1NC (Red) | Standard load | A22-01 | |||
Microload | A22-01S | ||||
Switch Blocks (two contacts) |
2NO (Black) | Standard load | A22-20 | Order Switch Blocks only when adding or replacing them. |
|
Microload | A22-20S | ||||
2NC (Red) | Standard load | A22-02 | |||
Microload | A22-02S | ||||
1NC + 1NO Contact (Black/Red) |
Standard load | A22-11 | |||
Microload | A22-11S | ||||
Lighting unit | Direct lighting | A22-TN | Used when changing the lighting method. |
||
Voltage- reduction lighting |
100 VAC | A22-T1 | |||
200 VAC | A22-T2 | ||||
Mounting Latches |
— | A22-3200 | Provided as standard. Order Mounting Latches only when mounting Switch Blocks or Lighting Units that are purchased individually. |
||
Lock Plate | — | A22Z-3380 | Use to fix the lever on the Switch. |
||
Control Boxes (Enclosures) |
One hole, yellow box | A22Z-B101Y | Material: Polycarbonate resin. When using a Control Box, 2NO, 2NC, or 1NC + 1NO two- contact Switch Blocks are not supported. * |
||
A22Z-B201Y |
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types,
refer to “Common Accessories and Tools (Order Separately)” on below.
* The A22NZ-B101Y and A22NZ-B201Y Control Box cannot be used in combination with the A22Z-3476-1 90-dia.
Legend Plates for Emergency Stop or the A22Z-EG[] E-stop Shrouds.
Common Accessories and Tools (Order Separately)
Common to Push-in Plus Terminal Block types (A22NE-PD/A22NE-P)/Screw Terminal Block types (A22E)
Item | Appearance | Classification | Model | Remarks | |
---|---|---|---|---|---|
Legend Plates for Emergency Stop |
60-dia. black letters on yellow back-ground |
A22Z-3466-1 | Used in combination with the rubber packing when the level of protection is to be met between panels. *1 | ||
90-dia. black letters on yellow back-ground |
A22Z-3476-1 | Used in combination with the rubber packing when the level of protection is to be met between panels. *1 *3 | |||
60-dia. black letters on yellow background |
A22Z-3466-2 | Used in combination with the rubber packing when the level of protection is to be met between panels. *1 | |||
Hole Plug | Round | A22Z-3530 | Used for covering the panel cutouts for future panel expansion. Black color. |
||
Connectors | Applicable cable diameter |
7 to 9 dia. | A22Z-3500-1 | Plastic connector used to extend a cable from the Switch Box. (Refer to Data Sheet). | |
9 to 11 dia. | A22Z-3500-2 | ||||
25-dia. Ring | — | A22Z-R25 | Use when mounting to a panel with a 25-dia. hole. (Refer to Data Sheet). Material: Rubber, Level of protection: IP65 |
||
30-dia. Resin Attachment |
— | A22Z-A30 | Use when mounting to a panel with a 30-dia. hole. (Refer to Data Sheet). A rubber packing is provided with the product. |
||
Lock Ring | — | A22Z-3360 | The body is equipped with a Lock Ring. This Lock Ring is used when a more secure lock feature is required. (Refer to Data Sheet). |
||
Tightening Tool |
— | A22Z-3905 | Used for tightening the tightening nut from the back side of the panel, and for removing the cap in lighted models. | ||
E-stop Shroud for EMO, Yellow |
— | A22Z-EG1 | Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and legend plate for EMERGENCY OFF come as a set. Use with an A22E Emergency Stop Switch (for emergency shutoff)*2 *3 |
||
E-stop Shroud for EMO, Yellow |
Legend plate for EMERGENCY OFF is not included. |
A22Z-EG10 | Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI S2 compatibility. Use with an A22E with EMO indication. (for emergency off) *3 |
||
E-stop Shroud for EMS, White |
— | A22Z-EG1-W | Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and legend plate for EMERGENCY STOP come as a set. Use with an A22E Emergency Stop Switch. (for emergency stop) *2 *3 |
||
E-stop Shroud for EMS, White |
Legend plate for EMERGENCY STOP is not included. |
A22Z-EG10-W | Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI S2 compatibility. Use with an A22E with EMS indication. (for emergency stop) *3 |
||
E-stop Shroud, Yellow |
Spacer Unit is not included. | A22Z-EG2 | SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI S2-compatible Shroud. (for emergency shutoff) *2 *3 Use together with an A22E Emergency Stop Switch. |
||
One Spacer Unit is included. | A22Z-EG21 | ||||
Two Spacer Units are included. |
A22Z-EG22 | ||||
E-stop Shroud for EMO, Yellow |
— | A22Z-EG3 | Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and legend plate for EMERGENCY OFF come as a set. Use with an A22E Emergency Stop Switch.(for emergency shutoff) *2 *3 |
||
Rubber Packing |
A22Z-R | Used together with accessories. Contains 10 packings. |
*1. If you use Legend Plates for Emergency Stop, set the thickness of the panels between 1 to 4 mm.
*2. These Shrouds are for use with the equipment only that conforms to SEMI standards. Do not use them for any
other applications (e.g. emergency stop switches for machines or devices such as Machine tools, Printing presses,
Industrial machinery, etc).
*3. The Control Boxes cannot be used in combination with the A22Z-3476-1 Legend Plates for Emergency Stop or the
A22Z-EG[] E-stop Shrouds.
Note: 1. Accessories for A22Z-EG1: one “EMERGENCY OFF” label, two rubber packings, and one lock ring
2. Accessories for A22Z-EG10: one rubber packing and one lock ring (without label)
Specifications | Emergency Stop Switches – A22NE-PD / A22NE-P / A22E series
A22NE-PD Push-in Plus Terminal Block Models
Certified Standard Ratings
• UL508 (File No. E76675), CSA C22.2 No.14
5 A at 125 VAC, 3 A at 250 VAC B300
• TÜV (EN60947-5-1) – Certified direct opening –
(EN60947-5-5)
AC-15 3 A at 125 VAC
DC-13 1 A at 30 VDC
• CCC (GB14048.5)
AC-15 3 A at 125 VAC
DC-13 1 A at 30 VDC
Applicable Standards
UL1059, UL486E
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
This fuse is not provided in the main unit.
Certified Standards
Certification body | Standards | File No. |
---|---|---|
UL * | UL508, C22.2 No.14 | E76675 |
TÜV SÜD | EN60947-5-1(Certified direct opening), EN60947-5-5 |
Consult your OMRON representative for details. |
CQC (CCC) | GB14048.5 | Consult your OMRON representative for details. |
Note: Only models with NC contacts have a direct opening mechanism.
* UL-certification for CSA C22.2 No. 14 has been obtained.
Ratings
Contacts (Standard Load)
Rated insulation voltage (V) |
Rated carry current (A) |
Rated voltage (V) |
Rated current (A) | |||
---|---|---|---|---|---|---|
AC15 (Inductive load) |
AC12 (Resistive load) |
DC13 (Inductive load) |
DC12 (Resistive load) |
|||
250 | 5 | 30 VAC | — | — | — | — |
125 VAC | 3 A | 5 A | — | — | ||
250 VAC | 1.5 A | 3 A | — | — | ||
30 VDC | — | — | 1 A | 2 A | ||
125 VDC | — | — | 0.22 A | 0.4 A | ||
250 VDC | — | — | 0.1 A | 0.2 A |
Note: 1. The above ratings were obtained by conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
Note: 2. Minimum applicable load: 1 mA at 5 VDC (Resistive load)
The operating range may vary depending on the usage conditions and type of load.
LED Lamp (A22NZ-L-RC)
Rated voltage | Operating voltage | Current value |
---|---|---|
24 VAC/VDC | 24 VAC/VDC ± 10% | Approx. 12 mA |
Characteristics
Operation | Turn-reset | Pull-reset | |||
---|---|---|---|---|---|
Non-lighted model | Lighted Model | Non-lighted model | Non-lighted model (Models with IP69K) |
||
A22NE-[]-PD[][]-N-[] | A22NE-M-PD[][]-C-[] | A22NE-MP-PD[][]-N-[] | A22NE-MP-PD[][]-N-69K | ||
Allowable operating frequency |
Mechanical | 30 operations/minute or less (One operation consists of set and reset operations.) | |||
Electrical | 30 operations/minute or less (One operation consists of set and reset operations.) | ||||
Insulation resistance *1 | 100 MΩ min. (at 500 VDC) | ||||
Contact resistance | 100 mΩ max. (initial value) | ||||
Dielectric strength |
Between terminals of same polarity*1 |
2,000 VAC, 50/60 Hz 1 minute (initial value) | |||
Between terminals of different polarity |
2,000 VAC, 50/60 Hz 1 minute (initial value) | ||||
Between each terminal and ground |
2,000 VAC, 50/60 Hz 1 minute (initial value) | ||||
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms) | |||
Shock resistance |
Malfunction | 250 m/s2 max. (contact separation within 1 ms) | |||
Durability | Mechanical | 300,000 operations min. (One operation consists of set and reset operations.) | 100,000 operations min. (One operation consists of set and reset operations.) |
||
Electrical (100 mA at 24 VAC (Resistive load)) |
250,000 operations min. (One operation consists of set and reset operations.) | 100,000 operations min. (One operation consists of set and reset operations.) |
|||
Electrical (3 mA at 250 VAC (Resistive load)) |
100,000 operations min. (One operation consists of set and reset operations.) | ||||
Ambient operating temperature *2 | -20 to +70°C | -20 to +55°C | -20 to +70°C | -20 to +70°C *3 | |
Ambient operating humidity | 35 to 85% RH | ||||
Ambient storage temperature *2 | -40 to +70°C | ||||
Degree of protection *4 | IP65 oil-resistant models | IP65 | IP65 oil-resistant models | IP69K | |
Electric shock protection class | Class II | ||||
PTI (tracking characteristic) | 175 | ||||
Degree of contamination | 3 (EN 60947-5-1) | ||||
Minimum direct opening stroke | 11 mm | ||||
Minimum direct opening force | 45 N | ||||
Conditional short-circuit current | 100 A (EN 60947-5-1) | ||||
Wight (for a 40-dia. head 2NC/2NO Operation Unit) |
Approx. 95 g | Approx. 95 g | Approx. 125 g | Approx. 135 g |
*1. State when an LED is not added between terminals of the same polarity on a lighting unit.
*2. With no icing or condensation.
*3. Capable of operation at up to 80°C under IP[]9K testing conditions per JIS D 5020.
*4. The degree of protection from the front of the panel.
Operating Characteristics
Item | Turn-reset | Pull-reset | |
---|---|---|---|
Lighted / non-lighted models | Non-lighted model | Non-lighted model (Models with IP69K) |
|
Total travel force (TTF) | 45 N max. | 60 N max. | 70 N max. |
Return force (RF) | 0.25N·m max. * | 60 N max. | 70 N max. |
Total travel (TT) | 10 ±1 mm | 5.5 ±1 mm |
* Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Terminal Arrangement
A22NE-P Push-in Plus Terminal Block Models
Certified Standard Ratings
• UL508 (File No. E76675), CSA C22.2 No.14
6 A at 240 VAC, 10 A at 120 VAC
• TÜV (EN60947-5-1) – Certified direct opening –
(EN60947-5-5)
AC-15 3 A at 240 VAC
DC-13 4 A at 24 VDC
• CCC (GB14048.5)
AC-15 3 A at 240 VAC
DC-13 4 A at 24 VDC
Applicable Standards
UL1059, UL486E (Push-in Plus Terminal Block Types)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not
provided in the main unit.
Certified Standards
Certification body | Standards | File No. |
---|---|---|
UL * | UL508, C22.2 No.14 | E76675 |
TÜV SÜD | EN60947-5-1 (Certified direct opening), EN60947-5-5 |
Consult your OMRON representative for details. |
CQC (CCC) | GB14048.5 | 2017010305959182 |
Note: Only models with NC contacts have a direct opening mechanism.
* UL-certification for CSA C22.2 No. 14 has been obtained.
Ratings
Contacts (Standard Load)
Rated insulation voltage (V) |
Rated carry current (A) |
Rated voltage (V) |
Rated current (A) | |||
---|---|---|---|---|---|---|
AC15 (Inductive load) |
AC12 (Resistive load) |
DC13 (Inductive load) |
DC12 (Resistive load) |
|||
600 | 10 | 24 VAC | 10 | 10 | — | — |
120 VAC | 6 | 10 | ||||
240 VAC | 3 | 6 | ||||
380 VAC | 1.9 | 2 | ||||
440 VAC | 1.6 | 2 | ||||
24 VDC | — | — | 4 | 8 | ||
120 VDC | 1.1 | 2.2 | ||||
240 VDC | 0.55 | 1.1 |
Note: 1. The above ratings were obtained by conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3)Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC (Resistive load)
The operating range may vary depending on the usage conditions and type of load.
LED Lamp
Rated voltage | Operating voltage | Current value |
---|---|---|
6 VAC/VDC | 6 VAC/VDC ± 10% | Approx. 11 mA |
12 VAC/VDC | 12 VAC/VDC ± 10% | Approx. 12 mA |
24 VAC/VDC | 24 VAC/VDC ± 10% | Approx. 12 mA |
100 VAC | 100 VAC ± 10% | Approx. 12 mA |
110 VAC | 110 VAC ± 10% | |
120 VAC | 100 VAC to 130 VAC | |
200 VAC | 200 VAC ± 10% | Approx. 12 mA |
220 VAC | 220 VAC ± 10% | |
230 VAC | 230 VAC ± 10% | |
240 VAC | 220 VAC to 250 VAC |
Characteristics
Operation | Turn-reset | Pull-reset | |||
---|---|---|---|---|---|
Non-lighted model | Lighted Model | Non-lighted model | |||
A22NE-[]-P[][][]-N | A22NE-M-P[][][]-[] | A22NE-MP-P[][][]-N | A22NE-MP-P[][][]-N-69K | ||
Allowable operating frequency |
Mechanical | 30 operations/minute or less (One operation consists of set and reset operations.) |
|||
Electrical | 30 operations/minute or less (One operation consists of set and reset operations.) |
||||
Insulation resistance *1 | 100 MΩ min. (at 500 VDC) | ||||
Contact resistance | 100 mΩ max. (initial value) | ||||
Dielectric strength |
Between terminals of same polarity *1 |
2,500 VAC, 50/60 Hz 1 minute (initial value) | |||
Between each terminal and ground |
2,500 VAC, 50/60 Hz 1 minute (initial value) | ||||
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms) | |||
Shock resistance |
Malfunction | 250 m/s2 max. (contact separation within 1 ms) | |||
Durability | Mechanical | 300,000 operations min. (One operation consists of set and reset operations.) |
100,000 operations min. (One operation consists of set and reset operations.) |
||
Electrical | 300,000 operations min. (One operation consists of set and reset operations.) |
100,000 operations min. (One operation consists of set and reset operations.) |
|||
Ambient operating temperature *2 |
-20 to +70°C | -20 to +55°C | -20 to +70°C | -20 to +70°C *3 | |
Ambient operating humidity |
35 to 85% RH | ||||
Ambient storage temperature *2 |
-40 to +70°C | ||||
Degree of protection*4 | IP65 oil-resistant models *5 | IP65 | IP65 oil-resistant models *5 | IP69K | |
Electric shock protection class |
Class II | ||||
PTI (tracking characteristic) |
175 | ||||
Degree of contamination | 3 (EN 60947-5-1) | ||||
Minimum direct opening stroke |
11 mm | ||||
Minimum direct opening force |
45 N | ||||
Conditional short-circuit current |
100 A (EN 60947-5-1) | ||||
Wight (for a 40-dia. Head 1NC/1NO Operation Unit) |
Approx. 55 g | Approx. 60 g | Approx. 85 g | Approx. 115 g |
*1. State when an LED is not added between terminals of the same polarity on a lighting unit. Does not apply to
lighted-type 100 to 200 V lighting units.
*2. With no icing or condensation.
*3. Capable of operation at up to 80°C under IP[]9K testing conditions per JIS D 5020.
*4. The degree of protection from the front of the panel.
*5. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
Operating Characteristics
Item | Turn-reset | Pull-reset | |
---|---|---|---|
Lighted / non-lighted models |
Non-lighted model | Non-lighted model (Models with IP69K) |
|
Total travel force (TTF) | 45 N max. | 60 N max. | 70 N max. |
Return force (RF) | 0.25N·m * max. | 60 N max. | 70 N max. |
Total travel (TT) | 10 ±1 mm | 5.5 ±1 mm | 5.5 ±1 mm |
* Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Terminal connection
Terminal wiring drawings of two-contact Switch Units
A22E Screw Terminal Block types
Certified Standard Ratings
• UL, cUL (File No. E41515)
6 A at 220 VAC, 10 A at 110 VAC
• TÜV (EN60947-5-1) (Low Voltage Directive)
3 A at 220 VAC
• CCC (GB14048.5)
3 A at 240 VAC, 1.5 A at 24 VDC
Certified Standards
Certification body | Standards | File No. |
---|---|---|
UL *1 | UL508, C22.2 No.14 | E41515 |
TÜV SÜD | EN60947-5-1 (Certified direct opening), EN60947-5-5 |
Consult your OMRON representative for details. |
CQC (CCC) | GB14048.5 | 2003010303070635 |
KOSHA *2 | EN60947-5-1 | Consult your OMRON representative for details. |
Note: 1. Only models with NC contacts have a direct opening mechanism.
2. A fuse is not provided.
*1. UL-certification for CSA C22.2 No. 14 has been obtained.
Certification has been obtained for individual Switch Blocks and Lighting Units.
*2. Some models have been certified.
Ratings
Contacts (Standard Load)
Rated carry current (A) |
Rated voltage (V) |
Rated current (A) | |||
---|---|---|---|---|---|
AC15 (Inductive load) |
AC12 (Resistive load) |
DC13 (Inductive load) |
DC12 (Resistive load) |
||
10 | 24 VAC | 10 | 10 | — | — |
110 VAC | 5 | 10 | |||
220 VAC | 3 | 6 | |||
380 VAC | 2 | 3 | |||
440 VAC | 1 | 2 | |||
24 VDC | — | — | 1.5 | 10 | |
110 VDC | 0.5 | 2 | |||
220 VDC | 0.2 | 0.6 | |||
380 VDC | 0.1 | 0.2 |
Note: 1. Rated current values are determined according to the testing conditions. The above ratings were obtained by
conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3)Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
LED Lamp
Rated voltage | Operating voltage | Current value |
---|---|---|
6 VAC/VDC | 6 VAC/VDC ± 5% | Approx. 8 mA |
12 VAC/VDC | 12 VAC/VDC ± 5% | |
24 VAC/VDC | 24 VAC/VDC ± 5% |
Voltage-reduction lighting
Rated voltage | Operating voltage | Rated current | Applicable lamp (BA9S/Base: 13) |
---|---|---|---|
110 VAC | 100 VAC (95 to 115 V) |
Approx. 8 mA | LED lamp A22-24A[] |
220 VAC | 200 VAC (190 to 230 V) |
Characteristics
Type | Turn-reset | Pull-reset | ||
---|---|---|---|---|
Non-lighted model | Lighted model | Non-lighted model | ||
Allowable operating frequency |
Mechanical | 30 operations/minute (One operation consists of set and reset operations.) | ||
Electrical | 30 operations/minute (One operation consists of set and reset operations.) | |||
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||
Contact resistance | 100 mΩ max. (initial value) | |||
Dielectric strength |
Between terminals of same polarity |
2,500 VAC, 50/60 Hz for 1 min. | ||
Between each terminal and ground |
2,500 VAC, 50/60 Hz for 1 min. | |||
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude (contact separation within 1 ms) | |||
Shock resistance |
Destruction | 1000 m/s2 | ||
Malfunction | 250 m/s2 max. (contact separation within 1 ms) | |||
Durability | Mechanical | 300,000 operations min. (One operation consists of set and reset operations.) | ||
Electrical | 300,000 operations min. (One operation consists of set and reset operations.) | |||
Ambient operating temperature *1 | -20 to +70°C | -20 to +55°C | -20 to +70°C | |
Ambient operating humidity | 35 to 85% RH | |||
Ambient storage temperature | -40 to +70°C | |||
Degree of protection | IP65 oil-resistant models *2 *3 | IP65 *2 | IP65 oil-resistant models *2 *3 | |
Electric shock protection class | Class II | |||
PTI (tracking characteristic) | 175 | |||
Degree of contamination | 3 (EN60947-5-1) | |||
Minimum direct opening stroke | 11 mm | |||
Minimum direct opening force | 45 N | |||
Conditional short-circuit current | 100 A (EN 60947-5-1) | |||
Weight (for a 40-dia. head 1NC/1NO Operation Unit) |
Approx. 65 g | Approx. 80 g | Approx. 100 g |
*1. With no icing or condensation.
*2. The degree of protection from the front of the panel.
*3. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
Operating Characteristics
Item | Turn-reset | Pull-reset |
---|---|---|
Total travel force (TTF) | 44.1 N max. | 58.8 N max. |
Return force (RF) | 0.25 N·m max. * | 58.8 N max. |
Total travel (TT) | 10 ±1 mm | 5.5 ±1 mm |
* Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Terminal connection
Terminal wiring drawings of two-contact Switch Units
Dimensions | Emergency Stop Switches – A22NE-PD / A22NE-P / A22E series
A22NE-PD Push-in Plus Terminal Block Models
Non-lighted Models
A22NE-MP-PD[][]-N
Pull-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
A22NE-MP-PD[][]-N-69K
Pull-reset (40-dia.) Degree of Protection: IP69K
A22NE-S-PD[][]-N
Small Turn-reset (30-dia.) Degree of Protection: IP65 oil-resistant models
A22NE-M-PD[][]-N
Medium Turn-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
Note: The dimensions the same even if the Operation Unit is replaced with the A22NE-MR[]-N or the A22NE-MR[]-N-RD.
A22NE-L-PD[][]-N
Large Turn-reset (60-dia.) Degree of Protection: IP65 oil-resistant models
Lighted Model
A22NE-M-PD[][]-C
Medium Turn-reset (40-dia.) Degree of Protection: IP65
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Accessories (Order Separately)
LED Lamp
A22NZ-L-RC
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to “Common Accessories and Tools (Order Separately)”.
A22NE-P Push-in Plus Terminal Block Models
Non-lighted Models
A22NE-MP-P[][]2-N
Pull-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
A22NE-MP-P[][]2-N-69K
Pull-reset (40-dia.) Degree of Protection: IP69K
A22NE-S-P[][]2-N
Small Turn-reset (30-dia.) Degree of Protection: IP65 oil-resistant models
A22NE-M-P[][]2-N
Medium Turn-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
Note: The dimensions the same even if the Operation Unit is replaced with the A22NE-MR[]-N or the A22NE-MR[]-N-RD.
A22NE-L-P[][]2-N
Large Turn-reset (60-dia.) Degree of Protection: IP65 oil-resistant models
Lighted Model
A22NE-M-P[][]2-[]
Medium Turn-reset (40-dia.) Degree of Protection: IP65
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Dimensions when a two-contact Switch Block is attached
Accessories (Order Separately)
Switch Block with Push-In Plus technology
Switch Block (one contact)
A22NZ-S-P1[]N
Switch Block (two contacts)
A22NZ-S-P2[]N
Lighting unit
A22NZ-T-[]PN
Mounting Latches
A22NZ-H-02
LED Lamp
A22NZ-L-[][]
Control Box
A22NZ-A-B01Y
Control Box
A22NZ-A-B101Y
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to “Common Accessories and Tools (Order Separately)” on below.
A22E Screw Terminal Block types
Non-lighted Models
A22E-MP
Medium Pull-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
A22E-S
Small Turn-reset (30-dia.) Degree of Protection: IP65 oil-resistant models
A22E-M
Medium Turn-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
Note: The dimensions are the same as for EMO/EMS indication models.
A22E-L
Large Turn-reset (60-dia.)Degree of Protection: IP65 oil-resistant models
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Lighted Model
A22EL-M
Medium Turn-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
Switch dimensions when mounted to a 2NO (2NC) one-piece switch block
Note: The operation unit is an example for the A22E-M.
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Accessories (Order Separately)
LED Lamp
A22-6[], 12[], 24[]
Control Box
A22Z-B101Y (1-hole)
Cable Draw-out Hole (Top View)
A22Z-B201Y (1-hole)
Cable Draw-out Hole (Top View)
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types,
refer to “Common Accessories and Tools (Order Separately)” on below.
Common Accessories and Tools (Order Separately)
Common to Push-in Plus Terminal Block types (A22NE-PD/A22NE-P)/Screw Terminal Block types (A22E)
Hole Plug
Round A22Z-3530
30-dia. Resin Attachment
A22Z-A30
Legend Plates for Emergency Stop
A22Z-3476-1 (90 dia.)
A22Z-3466-1 (60 dia.)
A22Z-3466-2 (60 dia.)
Lock Ring
A22Z-3360
Material: Nickel plated on iron
25-dia. Ring
A22Z-R25
Material: NBR (black)
Tightening Tool
A22Z-3905
Rubber Packing
A22Z-R
Connector
A22Z-3500
Common E-stop Shrouds
A22Z-EG1, A22Z-EG1-W, A22Z-EG10, A22Z-EG10-W
E-stop Shrouds
A22Z-EG2, A22Z-EG21, A22Z-EG22
E-stop Shroud
A22Z-EG3
Features | Emergency Stop Switches – A22NE-PD / A22NE-P / A22E series
- A22NE-PD
- The small size of the control panel is realized by conserving space and changing the direction of the wiring.
- A maximum of up to four contact points can be combined together in the contact-point configuration.
- Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models) / IP69K high-temperature, high-pressure cleaning (pull-reset models).
- A22NE-P
- The small size of the control panel is realized by conserving space and changing the direction of the wiring.
- A maximum of up to six contact points can be combined together in the contact-point configuration.
- Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models) / Supports IP69K high-temperature, high-pressure cleaning (pull-reset models).
- A lock lever mechanism that can be easily operated is adopted.
- A22E
- Increase wiring efficiency with three-row mounting of Switch Units.
- Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models).
Properties | Emergency Stop Switches – A22NE-PD / A22NE-P / A22E series
Emergency Stop Switches | A22NE-PD | A22NE-P | A22E | |||
---|---|---|---|---|---|---|
Minimum direct opening force | 45 N | |||||
Mounting hole diameter | 22 / 25 dia. | |||||
Weight | (for 40-dia 2 NC/2 NO) | Approx 95 g (Turn-reset) | (for 40-dia 1 NC/1 NO) | Approx 55 g (Turn-reset Model Non-lighted) | (for 40-dia 1 NC/1 NO) | Approx 65 g (Turn-reset Model Non-lighted) |
Approx 125 g (Pull-reset Model Non-lighted) | Approx 60 g (Turn-reset Model lighted) | Approx 80 g (Turn-reset Model lighted) | ||||
Approx 135 g (Pull-reset Model Non-lighted IP69K) | Approx 85 g (Pull-reset Model Non-lighted) | Approx 100 g (Pull-reset Model Non-lighted) | ||||
– | Approx 115 g (Pull-reset Model Non-lighted IP69K) | – | ||||
Contact Form | 1 NC, 2 NC, 1 NO/1 NC, 3 NC, 2 NO/1 NC, 1 NO/2 NC, 2 NO/2 NC, 1 NO/3 NC, 4 NC | 1 NC, 2 NC, 1 NO/1 NC, 3 NC, 1 NO/2 NC | 1 NC, 2 NC, 1 NO/1 NC, 3 NC, 1 NO/2 NC | |||
Degree of protection | IP65 / 69K | IP65 / 69K | IP65 | |||
Switch head size | dia. 30 / 40 / 60 mm |