OMRON Fiber Sensor - E3NX-FA series
OMRON Fiber Amplifier Sensor – E3NX-FA series
Model Numbers | Fiber Amplifier Sensor – E3NX-FA series
Fiber Amplifier Units
Type | Connecting method |
Appearance | Inputs / outputs | Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Standard models | Pre-wired (2 m) | 1 output | E3NX-FA11 2M | E3NX-FA41 2M | |
E3NX-FA11-5 2M *1 | — | ||||
Wire-saving Connector | 1 output | E3NX-FA6 | E3NX-FA8 | ||
Advanced models | Pre-wired (2 m) | 2 outputs + 1 input | E3NX-FA21 2M | E3NX-FA51 2M | |
Wire-saving Connector | 1 output + 1 input | E3NX-FA7 | E3NX-FA9 | ||
2 outputs | E3NX-FA7TW | E3NX-FA9TW | |||
M8 Connector | 1 output + 1 input | E3NX-FA24 | E3NX-FA54 | ||
2 outputs | — | E3NX-FA54TW | |||
Infrared models |
Pre-wired (2 m) | 1 output | E3NX-FAH11 2M | E3NX-FAH41 2M | |
Wire-saving Connector | 1 output | E3NX-FAH6 | E3NX-FAH8 | ||
Analog output models |
Pre-wired (2 m) | 2 outputs | E3NX-FA11AN 2M | E3NX-FA41AN 2M | |
Model for Sensor Communications Unit *2 |
Connector for Sensor Communications Unit |
— | E3NX-FA0 | ||
E3NX-FAH0 | |||||
Connector for Sensor Communications Unit Pre-wired (2 m) |
1 output | E3NX-FA10 2M | E3NX-FA40 2M |
*1. This type can prevent mutual interference for two units in the SHS2 mode.
*2. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
Accessories (Sold Separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Note: Protective stickers are provided.
Type | Appearance | Cable length |
No. of conductors |
Model | Applicable Fiber Amplifier Units |
---|---|---|---|---|---|
Master Connector | 2 m | 4 | E3X-CN21 | E3NX-FA7 E3NX-FA7TW E3NX-FA9 E3NX-FA9TW |
|
Slave Connector | 2 | E3X-CN22 | |||
Master Connector | 3 | E3X-CN11 | E3NX-FA6 E3NX-FA8 E3NX-FAH6 E3NX-FAH8 |
||
Slave Connector | 1 | E3X-CN12 |
Sensor I/O Connectors (Required for models for M8 Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Size | Cable | Appearance | Cable type | Model | ||
---|---|---|---|---|---|---|
M8 | Standard cable | Straight | 2m | 4-wire | XS3F-M421-402-A | |
5m | XS3F-M421-405-A | |||||
L-shaped | 2m | XS3F-M422-402-A | ||||
5m | XS3F-M422-405-A |
Mounting Bracket
A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
E39-L143 | 1 |
DIN Track
A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Appearance | Type | Model | Quantity |
---|---|---|---|
Shallow type, total length: 1 m | PFP-100N | 1 | |
Shallow type, total length: 0.5 m | PFP-50N | ||
Deep type, total length: 1 m | PFP-100N2 |
End Plate
Two End Plates are provided with the Sensor Communications Unit.
End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
PFP-M | 1 |
Cover
Attach these Covers to Amplifier Units.
Order a Cover when required, e.g., if you lose the covers.
Appearance | Model | Quantity |
---|---|---|
E39-G25 FOR E3NX-FA | 1 |
Related Products
Sensor Communications Units
Type | Appearance | Model |
---|---|---|
Sensor Communications Unit for EtherCAT | E3NW-ECT | |
Sensor Communications Unit for CompoNet | E3NW-CRT *1 | |
Sensor Communications Unit for CC-Link | E3NW-CCL | |
Distributed Sensor Unit *2 | E3NW-DS |
Refer to your OMRON website for details.
*1. E3NX-FAH0 can not be connected.
*2. The Distributed Sensor Unit can be connected to any of the Sensor Communications Units.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. CompoNet is a registered trademark of the ODVA.
CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association.
Specifications | Fiber Amplifier Sensor – E3NX-FA series
Standard models / Advanced models/ Infrared models
Type | Standard models | |||
---|---|---|---|---|
NPN output | E3NX-FA11 | E3NX-FA6 | E3NX-FA11-5 *1 | |
PNP output | E3NX-FA41 | E3NX-FA8 | — | |
Connecting method | Pre-wired | Wire-saving Connector | Pre-wired | |
Inputs/ outputs |
Outputs | 1 output | ||
External inputs | — | |||
Light source (wavelength) | Red, 4-element LED (625 nm) | |||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |||
Power consumption *2 | At Power supply voltage of 24 VDC Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.)Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.)Infrared models: Normal mode: 1080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1020 mW max. (Current consumption at 42 mA max.) |
|||
Control output | Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
|||
External inputs | — | |||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
|||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | |||
Response time |
Super-high-speed mode (SHS) | Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs | ||
High-speed mode (HS) | Operate or reset: 250 μs | |||
Standard mode (Stnd) | Operate or reset: 1 ms | |||
Giga-power mode (GIGA) | Operate or reset: 16 ms | |||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | |||
Maximum connectable Units | 30 | |||
No. of Units for mutual interference prevention *4 |
Super-high-speed mode (SHS) | 0 Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled. |
||
High-speed mode (HS) | 10 | |||
Standard mode (Stnd) | 10 | |||
Giga-power mode (GIGA) | 10 | |||
Functions | Automatic power control (APC) |
Always enabled. | ||
Dynamic power control (DPC) |
Provided | |||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms |
|||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | |||
Eco mode *6 | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | |||
Bank switching | Select from banks 1 to 4. | |||
Power tuning | Select from ON, OFF or Execution on power-up. | |||
Output 1 | Select from normal detection mode, area detection mode or differential detection mode. | |||
Output 2 | — | |||
External input | — | |||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | |||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||
Ambient temperature range *7 | Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above |
|||
Altitude | 2,000 m max. | |||
Installation environment | Pollution degree 3 | |||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||
Weight (packed state/Sensor only) | Approx. 115 g/ approx. 75 g |
Approx. 60 g/ approx. 20 g |
Approx. 115 g/ approx. 75 g |
|
Materials | Case | Polycarbonate (PC) | ||
Cover | Polycarbonate (PC) | |||
Cable | PVC | |||
Accessories | Instruction Manual |
Type | Advanced models | |||||
---|---|---|---|---|---|---|
NPN output | E3NX-FA21 | E3NX-FA7 | E3NX-FA7TW | E3NX-FA24 | — | |
PNP output | E3NX-FA51 | E3NX-FA9 | E3NX-FA9TW | E3NX-FA54 | E3NX-FA54TW | |
Connecting method | Pre-wired | Wire-saving Connector | M8 Connector | |||
Inputs/ outputs |
Outputs | 2 outputs | 1 output | 2 outputs | 1 output | 2 outputs |
External inputs | 1 input | 1 input | — | 1 input | — | |
Light source (wavelength) | Red, 4-element LED (625 nm) | |||||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |||||
Power consumption *2 | At Power supply voltage of 24 VDC Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.)Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.)Infrared models: Normal mode: 1080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1020 mW max. (Current consumption at 42 mA max.) |
|||||
Control output | Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
|||||
External inputs | Refer to *3. | — | Refer to *3. | — | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
|||||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection |
|||||
Response time |
Super-high-speed mode (SHS) | Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs | ||||
High-speed mode (HS) | Operate or reset: 250 μs | |||||
Standard mode (Stnd) | Operate or reset: 1 ms | |||||
Giga-power mode (GIGA) | Operate or reset: 16 ms | |||||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | |||||
Maximum connectable Units | 30 | |||||
No. of Units for mutual interference prevention *4 |
Super-high-speed mode (SHS) | 0 Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled. |
||||
High-speed mode (HS) | 10 | |||||
Standard mode (Stnd) | 10 | |||||
Giga-power mode (GIGA) | 10 | |||||
Functions | Automatic power control (APC) |
Always enabled. | ||||
Dynamic power control (DPC) |
Provided | |||||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms |
|||||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | |||||
Eco mode *6 | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | |||||
Bank switching | Select from banks 1 to 4. | |||||
Power tuning | Select from ON, OFF or Execution on power-up. | |||||
Output 1 | Select from normal detection mode, area detection mode or differential detection mode. | |||||
Output 2 | Select from normal detection mode, alarm output mode, error output mode or differential detection mode. |
— | Select from normal detection mode, alarm output mode, error output mode or differential detection mode. |
— | Select from normal detection mode, alarm output mode, error output mode or differential detection mode. |
|
External input | Select from input OFF, tuning, power tuning, emission OFF, Sensor OFF, zero reset, or bank switching. |
— | Select from input OFF, tuning, power tuning, emission OFF, Sensor OFF, zero reset, or bank switching. |
— | ||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | |||||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||||
Ambient temperature range *7 | Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above |
|||||
Altitude | 2,000 m max. | |||||
Installation environment | Pollution degree 3 | |||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||||
Weight (packed state/Sensor only) | Approx. 115 g/ approx. 75 g |
Approx. 60g/approx. 20g | Approx. 65 g/ approx. 25 g |
|||
Materials | Case | Polycarbonate (PC) | ||||
Cover | Polycarbonate (PC) | |||||
Cable | PVC | |||||
Accessories | Instruction Manual |
Type | Infrared models | ||
---|---|---|---|
NPN output | E3NX-FAH11 | E3NX-FAH6 | |
PNP output | E3NX-FAH41 | E3NX-FAH8 | |
Connecting method | Pre-wired | Wire-saving Connector |
|
Inputs/ outputs |
Outputs | 1 outputs | |
External inputs | — | ||
Light source (wavelength) | Infrared LED (870nm) | ||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | ||
Power consumption *2 | At Power supply voltage of 24 VDC Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.)Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.)Infrared models: Normal mode: 1080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1020 mW max. (Current consumption at 42 mA max.) |
||
Control output | Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
||
External inputs | — | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | ||
Response time |
Super-high-speed mode (SHS) | Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs | |
High-speed mode (HS) | Operate or reset: 250 μs | ||
Standard mode (Stnd) | Operate or reset: 1 ms | ||
Giga-power mode (GIGA) | Operate or reset: 16 ms | ||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | ||
Maximum connectable Units | 30 | ||
No. of Units for mutual interference prevention *4 |
Super-high-speed mode (SHS) | 0 Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled. |
|
High-speed mode (HS) | 10 | ||
Standard mode (Stnd) | 10 | ||
Giga-power mode (GIGA) | 10 | ||
Functions | Automatic power control (APC) |
Always enabled. | |
Dynamic power control (DPC) |
Provided | ||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms |
||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | ||
Eco mode *6 | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | ||
Bank switching | Select from banks 1 to 4. | ||
Power tuning | Select from ON or OFF. | ||
Output 1 | Select from normal detection mode or area detection mode. | ||
Output 2 | — | ||
External input | — | ||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | ||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||
Ambient temperature range *7 | Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above |
||
Altitude | 2,000 m max. | ||
Installation environment | Pollution degree 3 | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||
Weight (packed state/Sensor only) | Approx. 115 g/approx. 75 g | Approx. 60g/approx. 20g | |
Materials | Case | Polycarbonate (PC) | |
Cover | Polycarbonate (PC) | ||
Cable | PVC | ||
Accessories | Instruction Manual |
*1. This type can prevent mutual interference for two units in the SHS2 mode.
*2. At Power supply voltage of 10 to 30 VDC
Standard Models:
Normal mode : 990 mW max. (Current consumption: 33 mA max. at 30 VDC, 65 mA max. at 10 VDC)
Eco function ON : 780 mW max. (Current consumption: 26 mA max. at 30 VDC, 42 mA max. at 10 VDC)
Eco function LO : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 45 mA max. at 10 VDC)
Advanced Models:
Normal mode : 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 67 mA max. at 10 VDC)
Eco function ON : 810 mW max. (Current consumption: 27 mA max. at 30 VDC, 44 mA max. at 10 VDC)
Eco function LO : 870 mW max. (Current consumption: 29 mA max. at 30 VDC, 48 mA max. at 10 VDC)
Infrared models:
Normal mode : 1,260 mW max. (Current consumption: 42 mA max. at 30 VDC, 80 mA max. at 10 VDC)
Eco function ON : 1,050 mW max. (Current consumption: 35 mA max. at 30 VDC, 60 mA max. at 10 VDC)
Eco function LO : 1,140 mW max. (Current consumption: 38 mA max. at 30 VDC, 70 mA max. at 10 VDC)
*3. The following details apply to the input.
– | Contact input (relay or switch) | Non-contact input (transistor) | Input time*3-1 |
---|---|---|---|
NPN | ON: Shorted to 0 V (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (Sourcing current: 1 mA max.) OFF: Vcc – 1.5 V to Vcc (Leakage current: 0.1 mA max.) |
ON: 9 ms min. OFF: 20 ms min. |
PNP | ON: Shorted to Vcc (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V. |
ON: Vcc – 1.5 V to Vcc (Sinking current: 3 mA max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.) |
*3-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
*4. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of E3NX and E3NC. Check the mutual interference prevention unit count and response speed of each model.
*5. The bank is not reset by the user reset function or saved by the user save function.
*6. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
*7. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Analog output models/ Model for Sensor Communications Unit
Type | Analog output models |
Model for Sensor Communications Unit | |||
---|---|---|---|---|---|
NPN output | E3NX-FA11AN | E3NX-FA10 | E3NX-FA0 | E3NX-FAH0 | |
PNP output | E3NX-FA41AN | E3NX-FA40 | |||
Connecting method | Pre-wired | Connector for Sensor Communications Unit Pre-wired |
Connector for Sensor Communications Unit |
||
Inputs/ outputs |
Outputs | 2 outputs | 1 outputs | — *1 | |
External inputs |
— | — | |||
Light source (wavelength) |
Red, 4-element LED (625 nm) | Infrared LED (870nm) | |||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) |
Supplied from the connector through the communication units. | |||
Power consumption *2 | At Power supply voltage of 24 VDC Normal mode: 960 mW max. (Current consumption at 40 mA max.) Eco function ON: 770 mW max. (Current consumption at 32 mA max.) Eco function LO: 870 mW max. (Current consumption at 36 mA max.) |
At Power supply voltage of 24 VDC Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 26 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.) |
At Power supply voltage of 24 VDC Normal mode: 1,080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1,020 mW max. (Current consumption at 42 mA max.) |
||
Control output | Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
— | |||
Analog output (reference value) |
Voltage output: 1-5 VDC (10 kΩ or more connected load), temperature characteristics: 0.3% F.S. / °C |
— | |||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
||||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection |
Power supply reverse polarity protection and output short-circuit protection |
|||
Control output Response time |
Super-high- speed mode (SHS) |
Operate or reset: 80 μs |
Operate or reset: 32 μs | ||
High-speed mode (HS) |
Operate or reset: 250μs |
Operate or reset: 250 μs | |||
Standard mode (Stnd) |
Operate or reset: 1 ms |
Operate or reset: 1 ms | |||
Giga-power mode (GIGA) |
Operate or reset: 16 ms |
Operate or reset: 16 ms | |||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, percentage tuning (-99% to 99%)) or manual adjustment |
||||
Maximum connectable Units | 30 | 16 | With E3NW-ECT: 30 units (When connected to an OMRON NJ- series Controller.) With E3NW-CRT: 16 units (Note: E3NX-FAH0 can not be connected.) With E3NW-CCL: 16 units |
||
No. of Units for mutual inter- ference preven- tion *3 |
Super-high- speed mode (SHS) |
0 (The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.) |
|||
High-speed mode (HS) |
10 | ||||
Standard mode (Stnd) |
10 | ||||
Giga-power mode (GIGA) |
10 | ||||
Func- tions |
Automatic power control (APC) |
Always enabled. | |||
Dynamic power control (DPC) |
Provided | ||||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms |
||||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
Resetting settings *4 |
Select from initial reset (factory defaults) or user reset (saved settings). | ||||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). |
||||
Bank switching |
Select from banks 1 to 4. | ||||
Sensor OFF setting |
— | Select from ON or OFF. |
— | ||
Power tuning |
Select from ON or OFF. | ||||
Output 1 | Select from normal detection mode, area detection mode or differential detection mode (E3NX-FA10/40 only). |
||||
Output 2 | Select from Analog scaling or Analog offset |
— | Select from normal detection mode, alarm output mode, error output mode or differential detection mode (E3NX- FA0 only). |
||
Hysteresis width |
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. |
||||
Ambient illumination (Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
Ambient temperature range *5 |
Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C Storage: -30 to 70°C (with no icing or condensation) |
Operating: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above |
||||
Altitude | 2,000 m max. | ||||
Installation environment | Pollution degree 3 | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance (destruction) |
500 m/s2 for 3 times each in X, Y, and Z directions |
150 m/s2 for 3 times each in X, Y, and Z directions | |||
Weight (packed state/ Sensor only) |
Approx. 115 g/ approx. 75 g |
Approx. 95 g/ approx. 45 g |
Approx. 65 g/ approx. 25 g |
Approx. 65 g/ approx. 25 g |
|
Materials | Case | Polycarbonate (PC) | |||
Cover | Polycarbonate (PC) | ||||
Cable | PVC | ||||
Accessories | Instruction Manual |
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. At Power supply voltage of 10 to 30 VDC
Analog output models:
Normal mode : 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC)
Eco function ON : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC)
Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC)
*3. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
*4. The bank is not reset by the user reset function or saved by the user save function.
*5. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Sensing Distances
Standard models/ Advanced models/ Analog output models
Threaded Models
Sensing method |
Sensing direction |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
||||
Through-beam | Right-angle | M4 | E32-T11N 2M | 3,000 | 1,500 | 1,050 | 280 |
E32-LT11N 2M | 4,000*1 | 4,000*1 | 3,450 | 920 | |||
Straight | E32-T11R 2M | 3,000 | 1,500 | 1,050 | 280 | ||
E32-LT11 2M | 4,000*1 | 4,000*1 | 4,000*1 | 1,080 | |||
E32-LT11R 2M | 4,000*1 | 4,000*1 | 3,450 | 920 | |||
Reflective | Right-angle | M3 | E32-C31N 2M | 160 | 75 | 69 | 14 |
E32-C21N 2M | 440 | 190 | 130 | 39 | |||
M4 | E32-D21N 2M | 1,260 | 520 | 360 | 100 | ||
M6 | E32-C11N 2M | 1,170 | 520 | 480 | 100 | ||
E32-LD11N 2M | 1,260 | 520 | 360 | 100 | |||
Straight | M3 | E32-D21R 2M | 210 | 90 | 60 | 16 | |
E32-C31 2M | 490 | 220 | 150 | 44 | |||
E32-C31M 1M | |||||||
M4 | E32-D211R 2M | 210 | 90 | 60 | 16 | ||
M6 | E32-D11R 2M | 1,260 | 520 | 360 | 100 | ||
E32-CC200 2M | 2,100 | 900 | 600 | 180 | |||
E32-LD11 2M | 1,290 | 540 | 370 | 110 | |||
E32-LD11R 2M | 1,260 | 520 | 360 | 100 |
Cylindrical Models
Sensing method |
Size | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through- beam |
1 dia. | Top-view | E32-T223R 2M | 670 | 370 | 220 | 60 |
1.5 dia. | E32-T22B 2M | 1,020 | 600 | 330 | 90 | ||
3 dia. | E32-T12R 2M | 3,000 | 1,500 | 1,050 | 280 | ||
Side-view | E32-T14LR 2M | 1,120 | 670 | 390 | 100 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 210 | 90 | 60 | 16 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 42 | 18 | 12 | 4 | ||
3 dia. | E32-D22R 2M | 210 | 90 | 60 | 16 | ||
E32-D221B 2M | 450 | 210 | 130 | 40 | |||
E32-D32L 2M | 1,050 | 450 | 300 | 90 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 100 | 45 | 30 | 8 |
Flat Models
Sensing method |
Sensing direction | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
|||
Through-beam | Top-view | E32-T15XR 2M | 3,000 | 1,500 | 1,050 | 280 |
Side-view | E32-T15YR 2M | 1,120 | 670 | 390 | 100 | |
Flat-view | E32-T15ZR 2M | |||||
Reflective | Top-view | E32-D15XR 2M | 1,260 | 520 | 360 | 100 |
Side-view | E32-D15YR 2M | 300 | 150 | 78 | 24 | |
Flat-view | E32-D15ZR 2M |
Sleeve Models
Sensing method |
Sensing direction | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
|||
Through-beam | Side-view | E32-T24R 2M | 250 | 150 | 75 | 20 |
E32-T24E 2M | 670 | 370 | 220 | 60 | ||
Top-view | E32-T33 1M | 220 | 130 | 75 | 20 | |
E32-T21-S1 2M | 760 | 450 | 250 | 68 | ||
E32-TC200BR 2M | 3,000 | 1,500 | 1,050 | 280 | ||
Reflective | Side-view | E32-D24R 2M | 100 | 45 | 30 | 8 |
E32-D24-S2 2M | 180 | 79 | 67 | 14 | ||
Top-view | E32-D43M 1M | 42 | 18 | 12 | 4 | |
E32-D331 2M | 21 | 9 | 6 | 2 | ||
E32-D33 2M | 100 | 45 | 30 | 8 | ||
E32-D32-S1 0.5M | 94 | 40 | 27 | 7 | ||
E32-D31-S1 0.5M | ||||||
E32-DC200F4R 2M | 210 | 90 | 60 | 16 | ||
E32-D22-S1 2M | 370 | 160 | 100 | 30 | ||
E32-D21-S3 2M | ||||||
E32-DC200BR 2M | 1,260 | 520 | 360 | 100 | ||
E32-D25-S3 2M | 370 | 160 | 100 | 30 |
Small-spot, Reflective Models
Type | Spot diameter |
Center distance (mm) |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Variable spot |
0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | |||
0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | ||||
Parallel light |
4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | |||
E32-C31N 2M + E39-F3C | |||||||
Integrated lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | |||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | ||||
Small- spot |
0.1 dia. | 7 | E32-C41 1M + E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | |||
0.5 dia. | E32-C31 2M + E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | |||||
E32-C31N 2M + E39-F3A-5 | |||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | ||||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | |||||
E32-C31N 2M + E39-F3B | |||||||
3 dia. | 50 | E32-CC200 2M + E39-F18 | Spot diameter of 3 mm at 50 mm. | ||||
E32-C11N 2M + E39-F18 |
High-power Beam Models
Type | Sensing direction |
Center distance (mm) |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High- speed mode |
Super- high- speed mode |
||||
Through-beam models with integrated lens |
Right-angle | 15° | E32-LT11N 2M | 4,000*2 | 4,000*2 | 3,450 | 920 |
Top-view | 10° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 8,000 | |
15° | E32-LT11 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,080 | ||
E32-LT11R 2M | 4,000 *2 | 4,000 *2 | 3,450 | 920 | |||
Side-view | 30° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
Through-beam models with lenses |
Right-angle | 12° | E32-T11N 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 |
6° | E32-T11N 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Top-view | 12° | E32-T11R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 | |
6° | E32-T11R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Side-view | 60° | E32-T11R 2M + E39-F2 | 2,170 | 1,200 | 750 | 200 | |
Top-view | 12° | E32-T11 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,860 | |
6° | E32-T11 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60° | E32-T11 2M + E39-F2 | 3,450 | 1,980 | 1,290 | 320 | |
Top-view | 12° | E32-T51R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,500 | |
6° | E32-T51R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60° | E32-T51R 2M + E39-F2 | 2,100 | 1,080 | 750 | 200 | |
Top-view | 12° | E32-T81R-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,000 | |
6° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
Side-view | 60° | E32-T81R-S 2M + E39-F2 | 1,500 | 820 | 540 | 140 | |
Top-view | 12° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
6° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,100 | ||
Side-view | 60° | E32-T61-S 2M + E39-F2 | 2,520 | 1,350 | 900 | 240 | |
Top-view | 12° | E32-T51 2M + E39-F1-33 | 4,000 *2 | 4,000 *2 | 3,450 | 1,400 | |
6° | E32-T51 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Reflective models with integrated lens |
Top-view | 4° | E32-D16 2M | 40 to 4,000 *2 |
40 to 2,100 |
40 to 1,350 |
40 to 480 |
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View Models
Sensing method |
Sensing direction |
Aperture angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through-beam | Side-view | 1.5° | E32-A03 2M | 4,000 *1 | 2,670 | 1,800 | 500 |
E32-A03-1 2M | |||||||
3.4° | E32-A04 2M | 1,920 | 1,020 | 670 | 200 | ||
4° | E32-T24SR 2M | 4,000 *1 | 3,300 | 2,190 | 580 | ||
E32-T24S 2M | 4,000 *1 | 3,900 | 2,610 | 700 | |||
E32-T22S 2M | 4,000 *1 | 4,000 *1 | 3,750 | 1,000 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Models for Detection without Background Interference
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high-speed mode |
|||
Limited- reflective |
Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-L24S 2M | 0 to 4 | |||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
Transparent Object Detection (Retro-reflective Models)
Sensing method |
Feature | Size | Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Retro- reflective |
Film detection | M3 | E32-C31 2M + E39-F3R + E39-RP37 |
370 | 300 | — | |
Square | — | E32-R16 5M | 150 to 1,500 | ||||
Threaded | M6 | E32-R21 2M | 10 to 370 | 10 to 250 | |||
Hex-shaped | E32-LR11NP 2M + E39-RP1 |
2,020 | 1,800 | 1,500 | 550 |
Transparent Object Detection (Limited-reflective Models)
Sensing method |
Feature | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Limited- reflective |
Small size | Flat-view | E32-L24S 2M | 0 to 4 | |||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||||
Glass substrate alignment, 70°C |
E32-A08 2M | 10 to 20 | — | ||||
Standard/long-distance | E32-A12 2M | 12 to 30 | — | ||||
Side-view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
Glass substrate mapping, 70°C |
Top-view | E32-A09 2M | 15 to 38 | — |
Chemical-resistant, Oil-resistant Models
Sensing method |
Type | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through- beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 2,200 |
Chemical/ oil-resistant |
Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,600 | |
E32-T11F 2M | 4,000 *1 | 4,000 *1 | 3,900 | 1,000 | |||
Side-view | E32-T14F 2M | 2,100 | 1,200 | 750 | 200 | ||
Chemical/ oil-resistant at 150°C |
Top-view | E32-T51F 2M | 4,000 *1 | 4,000 *1 | 2,700 | 700 | |
Reflective | Semiconductors: Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
|||
Semiconductors: Resist stripping; 85°C |
E32-L11FS 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
|||||
Chemical/ oil-resistant |
E32-D12F 2M | — *2 | 280 | 190 | 60 | ||
Chemical- resistant cable |
E32-D11U 2M | 1,260 | 520 | 360 | 100 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Bending-resistant Models
Sensing method |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high-speed mode |
|||
Through-beam | 1.5 dia. | E32-T22B 2M | 1,020 | 600 | 330 | 90 |
M3 | E32-T21 2M | |||||
M4 | E32-T11 2M | 3,750 | 2,020 | 1,350 | 360 | |
Square | 32-T25XB 2M | 750 | 450 | 250 | 70 | |
Reflective | 1.5 dia. | E32-D22B 2M | 210 | 90 | 60 | 16 |
M3 | E32-D21 2M | |||||
3 dia. | E32-D221B 2M | 450 | 210 | 130 | 40 | |
M4 | E32-D21B 2M | |||||
M6 | E32-D11 2M | 1,260 | 520 | 360 | 100 | |
Square | E32-D25XB 2M | 360 | 150 | 90 | 30 |
Heat-resistant Models
Sensing method |
Heat-resistant temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
|||
Through-beam | 100°C | E32-T51R 2M | 2,400 | 1,200 | 840 | 225 |
150°C | E32-T51 2M | 4,000 *1 | 2,250 | 1,500 | 400 | |
200°C | E32-T81R-S 2M | 1,500 | 820 | 540 | 140 | |
350°C | E32-T61-S 2M | 2,520 | 1,350 | 900 | 240 | |
Reflective | 100°C | E32-D51R 2M | 1,000 | 420 | 280 | 80 |
150°C | E32-D51 2M | 1,680 | 670 | 480 | 144 | |
200°C | E32-D81R-S 2M | 630 | 270 | 180 | 54 | |
300°C | E32-A08H2 2M | 10 to 20 | — | |||
E32-A09H2 2M | 20 to 30 (center 25) | — | ||||
350°C | E32-D611-S 2M | 630 | 270 | 180 | 54 | |
E32-D61-S 2M | ||||||
400°C | E32-D73-S 2M | 420 | 180 | 120 | 36 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Area Detection Models
Sensing method |
Type | Sensing width | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through-beam | Area | 11 mm | E32-T16PR 2M | 4,000 *1 | 2,550 | 1,680 | 440 |
E32-T16JR 2M | 4,000 *1 | 2,250 | 1,440 | 380 | |||
30 mm | E32-T16WR 2M | 4,000 *1 | 3,900 | 2,550 | 680 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 1,050 | 450 | 300 | 90 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection Models
Sensing method |
Tube diameter |
Feature | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Tube- mounting |
3.2, 6.4, or 9.5 dia |
Stable residual quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
|||
8 to 10 dia | Mounting at multiple levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm |
||||
No restrictions |
Large tubes | E32-D36T 5M | Applicable tube: Transparent tube (no restrictions on diameter) |
||||
Liquid contact (heat-resistant up to 200°C) |
— | — | E32-D82F1 4M | Liquid-contact type |
Vacuum-resistant Models
Sensing method |
Heat-resistant temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
|||
Through-beam | 120 °C | E32-T51V 1M | 1,080 | 600 | 390 | 100 |
E32-T51V 1M + E39-F1V | 2,000 *1 | 2,000 *1 | 2,000 *1 | 520 | ||
200 °C | E32-T84SV 1M | 2,000*1 | 1,420 | 960 | 260 |
*1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Models for FPD, Semiconductors, and Solar Cells
Sensing method |
Application | Operating temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Limited- reflective |
Glass presence detection |
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-A08 2M | 10 to 20 | — | |||||
Glass substrate alignment |
300°C | E32-A08H2 3M | |||||
70°C | E32-A12 2M | 12 to 30 | — | ||||
Glass substrate mapping |
E32-A09 2M | 15 to 38 | — | ||||
300°C | E32-A09H2 2M | 20 to 30 (center 25) | — | ||||
Wet processes: Cleaning, Resist developing and etching |
60°C | E32-L11FP 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
||||
Wet process: Resist stripping |
85°C | E32-L11FS 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
||||
Through- beam |
Wafer mapping | 70°C | E32-A03 2M | 4,000 *1 | 2,670 | 1,800 | 500 |
E32-A03-1 2M | |||||||
E32-A04 2M | 1,920 | 1,020 | 670 | 200 | |||
E32-T24SR 2M | 4,000 *1 | 3,300 | 2,190 | 580 | |||
E32-T24S 2M | 4,000 *1 | 3,900 | 2,610 | 700 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Infrared models
Threaded Models
Sensing method |
Sensing direction |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
||||
Through- beam |
Right-angle | M4 | E32-T11N 2M | 280 | 190 | 130 | 55 |
Straight | E32-T11R 2M | ||||||
Reflective | Straight | M3 | E32-C31 2M | 50 | 37 | 25 | 8.5 |
M6 | E32-D11R 2M | 120 | 90 | 60 | 21 | ||
E32-CC200 2M | 200 | 150 | 100 | 35 |
Cylindrical Models
Sensing method |
Size | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
||||
Through- beam |
3 dia. | Top-view | E32-T12R 2M | 280 | 190 | 130 | 55 |
Side-view | E32-T14LR 2M | 100 | 75 | 80 | 21 | ||
Reflective | 3 dia. | Top-view | E32-D32L 2M | 100 | 75 | 50 | 17 |
Flat Models
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
|||
Through- beam |
Top-view | E32-T15XR 2M | 280 | 190 | 130 | 55 |
Side-view | E32-T15YR 2M | 100 | 75 | 80 | 21 | |
Flat-view | E32-T15ZR 2M | |||||
Reflective | Top-view | E32-D15XR 2M | 120 | 90 | 60 | 21 |
Side-view | E32-D15YR 2M | 28 | 20 | 13 | 5 | |
Flat-view | E32-D15ZR 2M |
Sleeve Models
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
|||
Through- beam |
Top-view | E32-TC200BR 2M | 280 | 190 | 130 | 55 |
Reflective | Top-view | E32-DC200BR 2M | 120 | 90 | 60 | 21 |
High-power Beam Models
Type | Sensing direction |
Aperture angle |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
||||
Through-beam models with integrated lens |
Side-view | 30° | E32-T14 2M | 1800 | 1200 | 820 | 360 |
Dimensions | Fiber Amplifier Sensor – E3NX-FA series
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Fiber Amplifier Units
Pre-wired Amplifier Units
E3NX-FA[]1(-5)
E3NX-FAH[]1
E3NX-FA[]AN
Amplifier Units with Wire-saving Connectors
E3NX-FA6
E3NX-FA7(TW)
E3NX-FA8
E3NX-FA9(TW)
E3NX-FAH6
E3NX-FAH8
Amplifier Units with M8 Connectors
E3NX-FA24
E3NX-FA54
E3NX-FA54TW
Amplifier Unit with Connector for Sensor Communications Unit
E3NX-FA0/FAH0
Accessories (Sold Separately)
Wire-saving Connectors
Master Connector
E3X-CN11
E3X-CN21
* E3X-CN11: 4-dia. cable with 3 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24),
Insulator diameter: 1.1 mm)
E3X-CN21: 4-dia. cable with 4 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Slave Connector
E3X-CN12
E3X-CN22
* E3X-CN12: 2.6-dia. cable with 1 conductor, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24),
Insulator diameter: 1.1 mm)
E3X-CN22: 4-dia. cable with 2 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24),
Insulator diameter: 1.1 mm)
Sensor I/O Connectors
Straight
XS3F-M421-40[]-A
L-shaped
XS3F-M422-40[]-A
Mounting Bracket
E39-L143
Material: Stainless steel (SUS304)
DIN Track
PFP-100N
PFP-50N
Material: Aluminum
* Dimensions in parentheses are for the PFP-50N.
PFP-100N2
Material: Aluminum
End Plate
PFP-M
Materials: Iron, zinc plating
คุณสมบัติ | Fiber Amplifier Sensor – E3NX-FA series
- ปรับปรุงประสิทธิภาพพื้นฐานด้วย 1.5 เท่าของระยะการตรวจจับและประมาณ 1/10 ตรวจจับวัตถุน้อยที่สุด
- การตั้งค่าที่ง่ายเป็นพิเศษด้วย Smart Tuning พร้อมช่วงการปรับความเข้มของแสงที่ขยาย 20 เท่าเป็น 40,000 : 1 การตรวจจับที่มีเสถียรภาพสูงสุดทำได้ด้วยการปรับความเข้มของแสงแม้กระทั่งสำหรับแสงตกกระทบที่อิ่มตัว
- ตัวอักษรสีขาวบนจอสีดำเพื่อการมองเห็นที่ชัดเจน
- Solution Viewer ที่แสดงเวลาที่ผ่านมาและความแตกต่างระดับเหตุการณ์ และ Change Finder ที่ช่วยให้คุณเห็นค่าการแสดงผลแม้กระทั่งสำหรับชิ้นงานที่รวดเร็ว
คุณสมบัติ | Fiber Amplifier Sensor – E3NX-FA series
Fiber Amplifier Sensor | E3NX-FA series |
---|---|
วิธีการเชื่อมต่อ | มีสาย, Connector ประหยัดสาย |
เอาต์พุต | 1 เอาต์พุต |
อินพุตภายนอก | 1 อินพุต |
แรงดันไฟฟ้า | 10 – 30 VDC |
ความสูง | สูงสุด 2,000 (ม.) |
วัสดุ | โพลีคาร์บอเนต (PC) |