OMRON Fiber Sensor - E3NX-MA series
OMRON Fiber Amplifier Sensor – E3NX-MA series
Model Numbers | Fiber Amplifier Sensor – E3NX-MA series
Fiber Amplifier Units
Type | Connecting method | Appearance | Inputs / outputs | Model | ||
---|---|---|---|---|---|---|
NPN output | PNP output | |||||
2-channel models *2 |
Standard Type | Pre-wired (2 m) | 2 outputs | E3NX-MA11 | E3NX-MA41 | |
Wire-saving Connector |
2 outputs | E3NX-MA6 | E3NX-MA8 | |||
Model for Sensor Communications Unit *1 |
Connector for Sensor Communications Unit |
— | E3NX-MA0 |
*1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
*2. Two Fiber Units can be connected to one Fiber Amplifier Unit.
Accessories (Sold Separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. *Protective stickers are provided.
Type | Appearance | Cable length |
No. of conductors |
Model | Applicable Fiber Amplifier Units |
---|---|---|---|---|---|
Master Connector | 2 m | 4 | E3X-CN21 | E3NX-MA6 E3NX-MA8 |
|
Slave Connector | 2 | E3X-CN22 |
Mounting Bracket
A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
E39-L143 | 1 |
DIN Track
A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Appearance | Type | Model | Quantity |
---|---|---|---|
Shallow type, total length: 1 m | PFP-100N | 1 | |
Shallow type, total length: 0.5 m | PFP-50N | ||
Deep type, total length: 1 m | PFP-100N2 |
End Plate
Two End Plates are provided with the Sensor Communications Unit. End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
PFP-M | 1 |
Related Products
Sensor Communications Units
Type | Appearance | Model |
---|---|---|
Sensor Communications Unit for EtherCAT | E3NW-ECT | |
Sensor Communications Unit for CC-Link | E3NW-CCL | |
Distributed Sensor Unit * | E3NW-DS |
Refer to your OMRON website for details.
* The Distributed Sensor Unit can be connected to any of the Sensor Communications Units.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
CC-Link is a registered trademark of Mitsubishi Electric Corporation.
The trademark is managed by the CC-Link Partner Association.
Specifications | Fiber Amplifier Sensor – E3NX-MA series
Ratings and Specifications
Type | Standard Type | Model for Sensor Communications Unit | ||
---|---|---|---|---|
NPN output | E3NX-MA11 | E3NX-MA6 | E3NX-MA0 | |
PNP output | E3NX-MA41 | E3NX-MA8 | ||
Connecting method | Pre-wired | Wire-saving Connector | Connector for Sensor Communications Unit |
|
Inputs/ outputs |
Outputs | 2 outputs | —*1 | |
External inputs | — | — | ||
Light source (wavelength) | Red, 4-element LED (625 nm) | |||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the connector through the Sensor Communications Unit | ||
Power consumption *2 | At Power supply voltage of 24 VDC Normal mode: 960 mW max. (Current consumption at 40 mA max.) Eco function ON: 770 mW max. (Current consumption at 32 mA max.) Eco function LO: 870 mW max. (Current consumption at 36 mA max.) |
|||
Control output | Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
— | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange) |
|||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | Power supply reverse polarity protection and output shortcircuit protection | ||
Response time |
Super-high-speed mode (SHS) | Operate or reset: 100 μs | ||
High-speed mode (HS) | Operate or reset: 450 μs | |||
Standard mode (Stnd) | Operate or reset: 1ms | |||
Giga-power mode (GIGA) | Operate or reset: 16ms | |||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | |||
Maximum connectable Units | 30 | With E3NW-ECT: 30 units *3 With E3NW-CCL: 16 units |
||
No. of Units for mutual interference prevention *4 |
9 Note: The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode. |
|||
Functions | Automatic power control (APC) | Always enabled. | ||
Dynamic power control (DPC) | Provided | |||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms | |||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | |||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | |||
Sensor OFF setting | — | Select from ON or OFF. | ||
Bank switching | Select from banks 1 to 4. | |||
Power tuning | Select from ON or OFF. | |||
Output 1 | Select from normal detection mode or area detection mode. | |||
Output 2 | Select from normal detection mode, AND output mode, OR output mode, XOR output mode, GAP output mode, Falling synchronization mode, Rising synchronization mode or area detection mode. | |||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | |||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||
Ambient temperature range *6 | Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above | |||
Altitude | 2,000 m max. | |||
Installation environment | Pollution degree 3 | |||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each in X, Y, and Z directions | ||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | |||
Weight (packed state/Sensor only) |
Approx. 115 g/ approx. 75 g |
Approx. 60g/ approx. 20g |
Approx. 65 g/ approx. 25 g |
|
Materials | Case | Polycarbonate (PC) | ||
Cover | Polycarbonate (PC) | |||
Cable | PVC | |||
Accessories | Instruction Manual |
Type | Standard Type | Model for Sensor Communications Unit |
||
---|---|---|---|---|
NPN output | E3NX-MA11 | E3NX-MA6 | E3NX-MA0 | |
PNP output | E3NX-MA41 | E3NX-MA8 | ||
Connecting method | Pre-wired | Wire-saving Connector | Connector for Sensor Communications Unit |
|
Inputs/ outputs |
Outputs | 2 outputs | —*1 | |
External inputs | — | — | ||
Light source (wavelength) | Red, 4-element LED (625 nm) | |||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the connector through the Sensor Communications Unit | ||
Power consumption *2 | At Power supply voltage of 24 VDC Normal mode: 960 mW max. (Current consumption at 40 mA max.) Eco function ON: 770 mW max. (Current consumption at 32 mA max.) Eco function LO: 870 mW max. (Current consumption at 36 mA max.) |
|||
Control output | Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
— | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange) |
|||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | Power supply reverse polarity protection and output shortcircuit protection | ||
Response time |
Super-high-speed mode (SHS) | Operate or reset: 100 μs | ||
High-speed mode (HS) | Operate or reset: 450 μs | |||
Standard mode (Stnd) | Operate or reset: 1ms | |||
Giga-power mode (GIGA) | Operate or reset: 16ms | |||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | |||
Maximum connectable Units | 30 | With E3NW-ECT: 30 units *3 With E3NW-CCL: 16 units |
||
No. of Units for mutual interference prevention *4 |
9 Note: The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode. |
|||
Functions | Automatic power control (APC) | Always enabled. | ||
Dynamic power control (DPC) | Provided | |||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms | |||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | |||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | |||
Sensor OFF setting | — | Select from ON or OFF. | ||
Bank switching | Select from banks 1 to 4. | |||
Power tuning | Select from ON or OFF. | |||
Output 1 | Select from normal detection mode or area detection mode. | |||
Output 2 | Select from normal detection mode, AND output mode, OR output mode, XOR output mode, GAP output mode, Falling synchronization mode, Rising synchronization mode or area detection mode. | |||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | |||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||
Ambient temperature range *6 | Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above | |||
Altitude | 2,000 m max. | |||
Installation environment | Pollution degree 3 | |||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each in X, Y, and Z directions | ||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | |||
Weight (packed state/Sensor only) |
Approx. 115 g/ approx. 75 g |
Approx. 60g/ approx. 20g |
Approx. 65 g/ approx. 25 g |
|
Materials | Case | Polycarbonate (PC) | ||
Cover | Polycarbonate (PC) | |||
Cable | PVC | |||
Accessories | Instruction Manual |
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. Power consumption
At Power supply voltage of 10 to 30 VDC
Standard Models:
Normal mode : 1080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC)
Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC)
*3. When connected to an OMRON NJ-series Controller.
*4. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
*5. The bank is not reset by the user reset function or saved by the user save function.
*6. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Sensing Distances
Threaded Models
Sensing method |
Size | Sensing direction |
Aperture angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
|||||
Through- beam |
M4 | Right-angle | 60° | E32-T11N 2M | 1,870 | 910 | 700 | 180 |
Straight | E32-T11R 2M | 1,870 | 910 | 700 | 180 | |||
15° | E32-LT11 2M | 4,000 *1 | 3,510 | 2,700 | 700 | |||
Right-angle | E32-LT11N 2M | 4,000 *1 | 2,990 | 2,300 | 590 | |||
Straight | E32-LT11R 2M | 4,000 *1 | 2,990 | 2,300 | 590 | |||
Reflective | M3 | Right-angle | 60° | E32-C31N 2M | 100 | 44 | 32 | 9 |
E32-C21N 2M | 480 | 190 | 140 | 43 | ||||
M4 | E32-D21N 2M | 800 | 320 | 240 | 72 | |||
M6 | E32-C11N 2M | 740 | 310 | 240 | 66 | |||
15° | E32-LD11N 2M | 790 | 310 | 240 | 71 | |||
M3 | Straight | 60° | E32-D21R 2M | 130 | 57 | 40 | 11 | |
E32-C31 2M | 330 | 130 | 100 | 30 | ||||
E32-C31M 1M | 330 | 130 | 100 | 30 | ||||
M4 | E32-D211R 2M | 130 | 57 | 40 | 11 | |||
M6 | E32-D11R 2M | 800 | 320 | 240 | 72 | |||
E32-CC200 2M | 1,340 | 540 | 400 | 120 | ||||
15° | E32-LD11 2M | 820 | 330 | 250 | 74 | |||
E32-LD11R 2M | 790 | 310 | 240 | 71 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Cylindrical Models
Sensing method |
Size | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through- beam |
1 dia. | Top-view | E32-T223R 2M | 520 | 260 | 150 | 45 |
1.5 dia. | E32-T22B 2M | 750 | 370 | 220 | 65 | ||
3 dia. | E32-T12R 2M | 1,870 | 910 | 700 | 180 | ||
Side-view | E32-T14LR 2M | 690 | 330 | 260 | 67 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 130 | 57 | 40 | 11 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 29 | 12 | 8 | 2 | ||
3 dia. | E32-D22R 2M | 130 | 57 | 40 | 11 | ||
E32-D221B 2M | 310 | 120 | 90 | 26 | |||
E32-D32L 2M | 680 | 280 | 200 | 58 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 68 | 28 | 20 | 5 |
Flat Models
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
|||
Through- beam |
Top-view | E32-T15XR 2M | 1,870 | 910 | 700 | 180 |
Side-view | E32-T15YR 2M | 690 | 330 | 260 | 67 | |
Flat-view | E32-T15ZR 2M | 690 | 330 | 260 | 67 | |
Reflective | Top-view | E32-D15XR 2M | 800 | 320 | 240 | 72 |
Side-view | E32-D15YR 2M | 180 | 76 | 52 | 16 | |
Flat-view | E32-D15ZR 2M | 180 | 76 | 52 | 16 |
Sleeve Models
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
|||
Through- beam |
Side-view | E32-T24R 2M | 140 | 71 | 50 | 12 |
E32-T24E 2M | 450 | 220 | 150 | 39 | ||
Top-view | E32-T21-S1 2M | 510 | 250 | 170 | 44 | |
E32-TC200BR 2M | 1,870 | 910 | 700 | 180 | ||
Reflective | Side-view | E32-D24R 2M | 68 | 28 | 20 | 5 |
E32-D24-S2 2M | 150 | 64 | 45 | 13 | ||
Top-view | E32-D43M 1M | 29 | 12 | 8 | 2 | |
E32-D331 2M | 13 | 5 | 4 | 1 | ||
E32-D33 2M | 68 | 28 | 20 | 5 | ||
E32-D32-S1 0.5M | 68 | 28 | 18 | 5 | ||
E32-D31-S1 0.5M | 68 | 28 | 20 | 5 | ||
E32-DC200F4R 2M | 130 | 57 | 40 | 11 | ||
E32-D22-S1 2M | 220 | 96 | 72 | 19 | ||
E32-D21-S3 2M | 220 | 96 | 72 | 19 | ||
E32-DC200BR 2M | 800 | 320 | 240 | 72 | ||
E32-D25-S3 2M | 220 | 96 | 72 | 19 |
Small-spot, Reflective Models
Type | Spot diameter |
Center distance (mm) |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Variable spot |
0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | |||
0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | ||||
Parallel light |
4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | |||
E32-C21N 2M + E39-F3C | Spot diameter of 0.2 mm at 17 mm. | ||||||
Integrated lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | |||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. (For all the sensing distance modes (40 to 100mm)) |
||||
Small- spot |
0.1 dia. | 7 | E32-C41 1M + E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | |||
0.5 dia. | E32-C31 2M + E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | |||||
E32-C21N 2M + E39-F3A-5 | |||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | ||||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | |||||
E32-C21N 2M + E39-F3B | |||||||
3 dia. | 50 | E32-CC200 2M + E39-F18 | Spot diameter of 3 mm at 50 mm. | ||||
E32-C11N 2M + E39-F18 |
High-power Beam Models
Type | Sensing direction |
Aperture angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through- beam models with integrated lens |
Right-angle | 15° | E32-LT11N 2M | 4,000 *2 | 2,990 | 2,300 | 590 |
Top-view | 10° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 5,200 | |
15° | E32-LT11 2M | 4,000 *2 | 3,510 | 2,700 | 700 | ||
E32-LT11R 2M | 4,000 *2 | 2,990 | 2,300 | 590 | |||
Side-view | 30° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,160 | |
Through- beam models with lenses |
Right-angle | 12° | E32-T11N 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,270 |
6° | E32-T11N 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,290 | ||
Top-view | 12° | E32-T11R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,270 | |
6° | E32-T11R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,290 | ||
Side-view | 60° | E32-T11R 2M + E39-F2 | 1,680 | 810 | 630 | 160 | |
Top-view | 12° | E32-T11 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,630 | |
6° | E32-T11 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,940 | ||
Side-view | 60° | E32-T11 2M + E39-F2 | 2,170 | 1,050 | 810 | 210 | |
Top-view | 12° | E32-T51R 2M + E39-F1 | 4,000 *2 | 2,850 | 2,190 | 570 | |
6° | E32-T51R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,830 | ||
Side-view | 60° | E32-T51R 2M + E39-F2 | 1,430 | 690 | 530 | 130 | |
Top-view | 12° | E32-T81R-S 2M + E39-F1 | 4,000 *2 | 3,270 | 2,520 | 650 | |
6° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,170 | ||
Side-view | 60° | E32-T81R-S 2M + E39-F2 | 860 | 420 | 320 | 84 | |
Top-view | 12° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,090 | |
6° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,960 | ||
Side-view | 60° | E32-T61-S 2M + E39-F2 | 1,440 | 700 | 540 | 140 | |
Top-view | 12° | E32-T51 2M + E39-F1-33 | 4,000 *2 | 2,990 | 2,300 | 590 | |
6° | E32-T51 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,270 | ||
Reflective models with integrated lens |
Top-view | 4° | E32-D16 2M | 40 to 4,000 *2 | 40 to 2,100 | 40 to 1,350 | 40 to 480 |
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View Models
Sensing method |
Sensing direction |
Aperture angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
||||
Through- beam |
Side-view | 1.5° | E32-A03 2M | 3,210 | 1,560 | 1,200 | 310 |
E32-A03-1 2M | 3,210 | 1,560 | 1,200 | 310 | |||
3.4° | E32-A04 2M | 1,200 | 580 | 450 | 110 | ||
4° | E32-T24SR 2M | 3,930 | 1,910 | 1,460 | 380 | ||
E32-T24S 2M | 4,000 *1 | 2,270 | 1,740 | 450 | |||
E32-T22S 2M | 4,000 *1 | 3,250 | 2,500 | 650 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Models for Detection without Background Interference
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
|||
Limited- reflective |
Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-L24S 2M | 0 to 4 | |||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
Transparent Object Detection (Retro-reflective Models)
Sensing method |
Feature | Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Retro- reflective |
Film detection | M3 | E32-C31 2M+ E39-F3R+E39-RP37 |
230 | 200 | — | |
Square | — | E32-R16 5M | 150 to 1,500 | ||||
Threaded | M6 | E32-R21 2M | 10 to 250 | ||||
Hex-shaped | E32-LR11NP 2M+ E39-RP1 |
1,280 | 1,080 | 1,000 | 360 |
Transparent Object Detection (Limited-reflective Models)
Sensing method |
Feature | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
||||
Limited- reflective |
Small size | Flat-view | E32-L24S 2M | 0 to 4 | |||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||||
Glass substrate alignment, 70°C |
E32-A08 2M | 15 to 25 | — | ||||
Standard/ long-distance |
E32-A12 2M | 12 to 30 | — | ||||
Side-view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
Glass substrate mapping, 70°C |
Top-view | E32-A09 2M | 15 to 38 | — |
Chemical-resistant, Oil-resistant Models
Sensing method |
Type | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
||||
Through- beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,340 |
Chemical/ oil-resistant |
Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,040 | |
E32-T11F 2M | 4,000 *1 | 3,380 | 2,600 | 670 | |||
Side-view | E32-T14F 2M | 1,340 | 650 | 500 | 130 | ||
Chemical/ oil-resistant at 150°C |
Top-view | E32-T51F 2M | 4,000 *1 | 2,340 | 1,800 | 460 | |
Reflective | Semiconductors: Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
|||
Semiconductors: Resist stripping; 85°C |
E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
|||||
Chemical/ oil-resistant |
E32-D12F 2M | — *2 | 170 | 130 | 39 | ||
Chemical- resistant cable |
E32-D11U 2M | 800 | 320 | 240 | 72 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Bending-resistant Models
Sensing method |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
|||
Through- beam |
1.5 dia. | E32-T22B 2M | 750 | 370 | 220 | 65 |
M3 | E32-T21 2M | 670 | 330 | 220 | 58 | |
M4 | E32-T11 2M | 2,410 | 1,170 | 900 | 230 | |
Square | E32-T25XB 2M | 500 | 250 | 170 | 43 | |
Reflective | 1.5 dia. | E32-D22B 2M | 130 | 57 | 40 | 11 |
M3 | E32-D21 2M | 130 | 57 | 40 | 11 | |
3 dia. | E32-D221B 2M | 310 | 120 | 90 | 26 | |
M4 | E32-D21B 2M | 310 | 120 | 90 | 26 | |
M6 | E32-D11 2M | 800 | 320 | 240 | 72 | |
Square | E32-D25XB 2M | 220 | 92 | 60 | 18 |
Heat-resistant Models
Sensing method |
Heat-resistant temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
|||
Through- beam |
100°C | E32-T51R 2M | 1,500 | 720 | 560 | 140 |
150°C | E32-T51 2M | 2,680 | 1,300 | 1,000 | 260 | |
200°C | E32-T81R-S 2M | 960 | 460 | 360 | 93 | |
350°C | E32-T61-S 2M | 1,600 | 780 | 600 | 150 | |
Reflective | 100°C | E32-D51R 2M | 640 | 250 | 190 | 57 |
150°C | E32-D51 2M | 1,070 | 430 | 320 | 96 | |
200°C | E32-D81R-S 2M | 380 | 150 | 120 | 34 | |
300°C | E32-A08H2 2M | 15 to 25 | — | |||
E32-A09H2 2M | 20 to 30 (center 25) | — | ||||
350°C | E32-D61-S 2M | 380 | 150 | 120 | 34 | |
400°C | E32-D73-S 2M | 250 | 100 | 80 | 22 |
Area Detection Models
Sensing method |
Type | Sensing width |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high- speed mode |
||||
Through- beam |
Area | 11 mm | E32-T16PR 2M | 3,010 | 1,460 | 1,120 | 290 |
E32-T1s6JR 2M | 2,610 | 1,260 | 970 | 250 | |||
30 mm | E32-T16WR 2M | 4,000 *1 | 2,240 | 1,720 | 440 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 670 | 270 | 200 | 60 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection Models
Sensing method |
Tube diameter |
Feature | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Tube- mounting |
3.2, 6.4, or 9.5 dia |
Stable residual quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
|||
8 to 10 dia | Mounting at multiple levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm |
||||
No restrictions | Large tubes | E32-D36T 2M | Applicable tube: Transparent tube (no restrictions on diameter) | ||||
Liquid contact (heat-resistant up to 200°C) |
— | — | E32-D82F1 4M | Liquid-contact type |
Vacuum-resistant Models
Sensing method |
Heat-resistant temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
|||
Through- beam |
120°C | E32-T51V 1M | 690 | 330 | 260 | 67 |
E32-T51V 1M+E39-F1V | 2,000 *1 | 1,760 | 1,360 | 350 | ||
200°C | E32-T84SV 1M | 1,710 | 830 | 640 | 160 |
*1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Models for FPD, Semiconductors, and Solar Cells
Sensing method |
Application | Operating temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Limited- reflective |
Glass presence detection |
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
Glass substrate alignment |
E32-A08 2M | 15 to 25 | — | ||||
300°C | E32-A08H2 2M | 15 to 25 | — | ||||
70°C | E32-A12 2M | 12 to 30 | — | ||||
Glass substrate mapping |
E32-A09 2M | 15 to 38 | — | ||||
300°C | E32-A09H2 2M | 20 to 30 (center 25) | — | ||||
Wet processes: Cleaning, Resist developing and etching |
60°C | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
||||
Wet process: Resist stripping |
85°C | E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
||||
Through- beam |
Wafer mapping | 70°C | E32-A03 2M | 3,210 | 1,560 | 1,200 | 310 |
E32-A03-1 2M | 3,210 | 1,560 | 1,200 | 310 | |||
E32-A04 2M | 1,200 | 580 | 450 | 110 | |||
E32-T24SR 2M | 3,930 | 1,910 | 1,460 | 380 | |||
E32-T24S 2M | 4,000 *1 | 2,270 | 1,740 | 450 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Dimensions | Fiber Amplifier Sensor – E3NX-MA series
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Fiber Amplifier Units
Pre-wired Amplifier Units
E3NX-MA11
E3NX-MA41
Amplifier Units with Wire-saving Connectors
E3NX-MA6
E3NX-MA8
Amplifier Unit with Connector for
Sensor Communications Unit
E3NX-MA0
Accessories (Sold Separately)
Wire-saving Connectors
Master Connector
E3X-CN21
Slave Connector
E3X-CN22
Mounting Bracket
E39-L143
DIN Track
PFP-100N
PFP-50N
PFP-100N2
End Plate
PFP-M
คุณสมบัติ | Fiber Amplifier Sensor – E3NX-MA series
- Fiber Amplifier 2 ช่องใหม่มีฟังก์ชัน 2 ยูนิตในขนาดทั่วไปของยูนิตเดียวซึ่งมีส่วนช่วยลดขนาดอุปกรณ์และแผงควบคุม
- ประสิทธิภาพการตรวจจับที่มีความเสถียรสูงแม้จะมี 2 ช่องสัญญาณตั้งแต่วัตถุโปร่งใสไปจนถึงชิ้นงานที่มีการสะท้อนแสงต่ำ
- ง่ายต่อการตั้งค่าความเข้มข้นของแสงและเกณฑ์โดยอัติโนมัติ
- Connector แบบประหยัดสายไฟช่วยลดการเดินสายไฟ
คุณสมบัติ | Fiber Amplifier Sensor – E3NX-MA series
Fiber Amplifier Sensor | E3NX-MA series |
---|---|
วิธีการเชื่อมต่อ | มีสาย, Connector ประหยัดสาย, Connector Unit สำหรับการเชื่อมต่อเซนเซอร์ |
เอาต์พุต | 2 เอาต์พุต |
แรงดันไฟฟ้า | 10 – 30 VDC |
ยูนิตเชื่อมต่อสูงสุด | 30 |
วัสดุ | โพลีคาร์บอเนต (PC) |