OMRON Fiber Sensor - E3X-HD series
OMRON Fiber Amplifier Sensor – E3X-HD series
Model Numbers | Fiber Amplifier Sensor – E3X-HD series
Fiber Amplifier Units
Standard models
Appearance | Connecting method | Model | |
---|---|---|---|
NPN output | PNP output | ||
Pre-wired (2 m) | E3X-HD11 2M | E3X-HD41 2M | |
Wire-saving Connector | E3X-HD6 | E3X-HD8 | |
M8 Connector | E3X-HD14 | E3X-HD44 |
Model for Sensor Communications Unit
Appearance | Model | Applicable Sensor Communications Unit |
---|---|---|
E3X-HD0 | E3X-ECT | |
E3X-CRT |
Accessories (sold separately)
Wire-saving connectors (Required for models for Wire-saving Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. * Protective stickers: provided.
Type | Appearance | Cable length | Number of conductors | Model |
---|---|---|---|---|
Master connector | 2 m | 3 | E3X-CN11 | |
Slave connector | 1 | E3X-CN12 |
Sensor I/O Connectors (Required for models with M8 Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Size | Cable | Appearance | Cable type | Models | ||
---|---|---|---|---|---|---|
M8 | Standard cable | Straight | 2m | 4-wire | XS3F-M421-402-A | |
5m | XS3F-M421-405-A | |||||
L-shaped | 2m | XS3F-M422-402-A | ||||
5m | XS3F-M422-405-A |
Mounting Bracket
A Mounting Bracket is not provided with the Fiber Amplifier Unit and must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
E39-L143 | 1 |
DIN Track
A Din Track is not provided with the Fiber Amplifier Unit and must be ordered separately as required.
Appearance | Type | Model | Quantity |
---|---|---|---|
Shallow type, total length: 1 m | PFP-100N | 1 | |
Shallow type, total length: 0.5 m | PFP-50N | ||
Deep type, total length: 1 m | PFP-100N2 |
End Plate
Two End Plates are provided with the Sensor Communications Unit.
End Plates are not provided with the Fiber Amplifier Unit and must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
PFP-M | 1 |
Specifications | Fiber Amplifier Sensor – E3X-HD series
Ratings and Specifications
Type | Standard | Model for Sensor Communications Unit *1 | |||
---|---|---|---|---|---|
NPN output | E3X-HD11 | E3X-HD6 | E3X-HD14 | E3X-HD0 | |
PNP output | E3X-HD41 | E3X-HD8 | E3X-HD44 | ||
Connecting method | Pre-wired | Wire-saving Connector *2 |
M8 connector |
Communications Unit connector |
|
Light source (wavelength) | Red, 4-element LED (625 nm) | ||||
Power supply voltage | 12 to 24 VDC ±10%, ripple (P-P) 10% max. | Supplied from the connector through the Sensor Communications Unit |
|||
Power consump tion |
Normal mode | 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC) |
|||
Eco ON | 530 mW max. (Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC) |
||||
Eco LO | 640 mW max. (Current consumption: 26 mA max. at 24 VDC, 53 mA max.at 12 VDC) |
– | |||
Control output | Load power supply voltage: 26.4 VDC max., open- collector output Load current: Groups of 1 to 3 Amplifier Units: 100mA max., Groups of 4 to 16 Amplifier Units: 20mA max. Residual voltage: At load current of less than 10 mA: 1 V max., At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max. |
– | |||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection |
Power supply reverse polarity protection and output short- circuit protection |
|||
Response time |
Super-high-speed mode (SHS) *3 |
NPN outputs: Operate or reset: 50 μs PNP outputs: Operate or reset: 55 μs |
– | ||
High-speed Mode (HS) |
Operate or reset: 250 μs (default setting) | ||||
Standard Mode (STND) |
Operate or reset: 1 ms | ||||
Giga-power Mode (GIGA) |
Operate or reset: 16 ms | ||||
Maximum connectable Units | 16 units | with E3X-CRT: 16 units with E3X-ECT: 30 units |
|||
Mutual interference prevention |
Possible for up to 10 units (optical communications sync) *3 | ||||
Auto power control (APC) | Always ON | ||||
Other functions | Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot), zero reset, resetting settings, and Eco mode |
||||
Ambient illumination (Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
Ambient temperature range | OOperating: Groups of 1 to 2 Amplifiers: -25 to 55°C, Groups of 3 to 10 Amplifiers: -25 to 50°C, Groups of 11 to 16 Amplifiers: -25 to 45°C Storage: -30 to 70°C (with no icing or condensation) |
Operating: Groups of 1 to 2 Amplifiers: 0 to 55°C, Groups of 3 to 10 Amplifiers: 0 to 50°C, Groups of 11 to 16 Amplifiers: 0 to 45°C, Groups of 17 to 30 Amplifiers: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
10 to 150 Hz with a 0.7-mm double amplitude for 80 minutes each in X, Y, and Z directions |
|||
Shock resistance (destruction) |
500 m/s2 for 3 times each in X, Y, and Z directions |
150 m/s2 for 3 times each in X, Y, and Z directions |
|||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) |
– | |||
Weight (packed state/unit only) |
Approx. 105 g/ Approx. 65 g |
Approx. 60 g/ Approx. 20 g |
Approx. 70 g/ Approx. 25 g |
Approx. 65 g/Approx. 25 g | |
Materials | Case | Polycarbonate (PC) | Heat-resistant ABS (connector: PBT) |
||
Cover | Polycarbonate (PC) | ||||
Cable | PVC | – | |||
Accessories | Instruction Manual |
*1. The E3X-ECT EtherCAT Sensor Communications Unit and the E3X-CRT CompoNet Sensor Communications Unit can be used.
*2. Use either the E3X-CN11 (master connector, 3 conductors) or the E3X-CN12 (slave connector, 1 conductor).
*3. The communications function and mutual interference prevention function are disabled when the detection mode is set to Super-high-speed mode (SHS).
When including E3X-DA-S with activated power tuning, mutual interference prevention is possible for up to 6 units.
When including E3X-MDA with activated power tuning, mutual interference prevention is possible for up to 5 units.
Sensing Distances
Threaded Models
Sensing method |
Sensing direction |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
||||
Through-beam | Right-angle | M4 | E32-T11N 2M | 2,000 | 1,000 | 700 | 280 |
E32-LT11N 2M | 4,000 * | 3,500 | 2,300 | 920 | |||
Straight | E32-T11R 2M | 2,000 | 1,000 | 700 | 280 | ||
E32-LT11 2M | 4,000 * | 4,000 * | 2,700 | 1,080 | |||
E32-LT11R 2M | 4,000 * | 3,500 | 2,300 | 920 | |||
Reflective | Right-angle | M3 | E32-C31N 2M | 110 | 50 | 46 | 14 |
E32-C21N 2M | 290 | 130 | 90 | 39 | |||
M4 | E32-D21N 2M | 840 | 350 | 240 | 100 | ||
M6 | E32-C11N 2M | 780 | 350 | 320 | 100 | ||
E32-LD11N 2M | 840 | 350 | 240 | 100 | |||
Straight | M3 | E32-D21R 2M | 140 | 60 | 40 | 16 | |
E32-C31 2M | 330 | 150 | 100 | 44 | |||
E32-C31M 1M | |||||||
M4 | E32-D211R 2M | 140 | 60 | 40 | 16 | ||
M6 | E32-D11R 2M | 840 | 350 | 240 | 100 | ||
E32-CC200 2M | 1,400 | 600 | 400 | 180 | |||
E32-LD11 2M | 860 | 360 | 250 | 110 | |||
E32-LD11R 2M | 840 | 350 | 240 | 100 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Cylindrical Models
Sensing method |
Size | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through- beam |
1 dia. | Top-view | E32-T223R 2M | 450 | 250 | 150 | 60 |
1.5 dia. | E32-T22B 2M | 680 | 400 | 220 | 90 | ||
3 dia. | E32-T12R 2M | 2,000 | 1,000 | 700 | 280 | ||
Side-view | E32-T14LR 2M | 750 | 450 | 260 | 100 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 140 | 60 | 40 | 16 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 28 | 12 | 8 | 4 | ||
3 dia. | E32-D22R 2M | 140 | 60 | 40 | 16 | ||
E32-D221B 2M | 300 | 140 | 90 | 40 | |||
E32-D32L 2M | 700 | 300 | 200 | 90 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 70 | 30 | 20 | 8 |
Flat Models
Sensing method |
Sensing direction | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
|||
Through-beam | Top-view | E32-T15XR 2M | 2,000 | 1,000 | 700 | 280 |
Side-view | E32-T15YR 2M | 750 | 450 | 260 | 100 | |
Flat-view | E32-T15ZR 2M | |||||
Reflective | Top-view | E32-D15XR 2M | 840 | 350 | 240 | 100 |
Side-view | E32-D15YR 2M | 200 | 100 | 52 | 24 | |
Flat-view | E32-D15ZR 2M |
Sleeve Models
Sensing method |
Sensing direction | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
|||
Through-beam | Side-view | E32-T24R 2M | 170 | 100 | 50 | 20 |
E32-T24E 2M | 450 | 250 | 150 | 60 | ||
Top-view | E32-T33 1M | 150 | 90 | 50 | 20 | |
E32-T21-S1 2M | 510 | 300 | 170 | 68 | ||
E32-TC200BR 2M | 2,000 | 1,000 | 700 | 280 | ||
Reflective | Side-view | E32-D24R 2M | 70 | 30 | 20 | 8 |
E32-D24-S2 2M | 120 | 53 | 45 | 14 | ||
Top-view | E32-D43M 1M | 28 | 12 | 8 | 4 | |
E32-D331 2M | 14 | 6 | 4 | 2 | ||
E32-D33 2M | 70 | 30 | 20 | 8 | ||
E32-D32-S1 0.5M | 63 | 24 | 18 | 7 | ||
E32-D31-S1 0.5M | ||||||
E32-DC200F4R 2M | 140 | 60 | 40 | 16 | ||
E32-D22-S1 2M | 250 | 110 | 72 | 30 | ||
E32-D21-S3 2M | ||||||
E32-DC200BR 2M | 840 | 350 | 240 | 100 | ||
E32-D25-S3 2M | 250 | 110 | 72 | 30 |
Small-spot, Reflective Models
Type | Spot diameter |
Center distance (mm) |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Variable spot |
0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M+E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | |||
0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M+E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | ||||
Parallel light |
4 dia. | 0 to 20 | E32-C31 2M+E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | |||
E32-C31N 2M+E39-F3C | |||||||
Integrated lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | |||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | ||||
Small- spot |
0.1 dia. | 7 | E32-C41 1M+E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | |||
0.5 dia. | E32-C31 2M+E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | |||||
E32-C31N 2M+E39-F3A-5 | |||||||
0.2 dia. | 17 | E32-C41 1M+E39-F3B | Spot diameter of 0.2 mm at 17 mm. | ||||
0.5 dia. | E32-C31 2M+E39-F3B | Spot diameter of 0.5 mm at 17 mm. | |||||
E32-C31N 2M+E39-F3B | |||||||
3 dia. | 50 | E32-CC200 2M+E39-F18 | Spot diameter of 3 mm at 50 mm. | ||||
E32-C11N 2M+E39-F18 |
High-power Beam Models
Type | Sensing direction |
Aperture angle |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High- speed mode |
Super- high- speed mode |
||||
Through-beam models with integrated lens |
Right-angle | 15° | E32-LT11N 2M | 4,000 *2 | 3,500 | 2,300 | 920 |
Top-view | 10° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 8,000 | |
15° | E32-LT11 2M | 4,000 *2 | 4,000 *2 | 2,700 | 1,080 | ||
E32-LT11R 2M | 4,000 *2 | 3,500 | 2,300 | 920 | |||
Side-view | 30° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
Through-beam models with lenses |
Right-angle | 12° | E32-T11N 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 |
6° | E32-T11N 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Top-view | 12° | E32-T11R 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 | |
6° | E32-T11R 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Side-view | 60° | E32-T11R 2M+E39-F2 | 1,450 | 800 | 500 | 200 | |
Top-view | 12° | E32-T11 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,860 | |
6° | E32-T11 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60° | E32-T11 2M+E39-F2 | 2,300 | 1,320 | 860 | 320 | |
Top-view | 12° | E32-T51R 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 3,900 | 1,500 | |
6° | E32-T51R 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60° | E32-T51R 2M+E39-F2 | 1,400 | 720 | 500 | 200 | |
Top-view | 12° | E32-T81R-S 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 2,700 | 1,000 | |
6° | E32-T81R-S 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
Side-view | 60° | E32-T81R-S 2M+E39-F2 | 1,000 | 550 | 360 | 140 | |
Top-view | 12° | E32-T61-S 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
6° | E32-T61-S 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,100 | ||
Side-view | 60° | E32-T61-S 2M+E39-F2 | 1,680 | 900 | 600 | 240 | |
Top-view | 12° | E32-T51 2M+E39-F1-33 | 4,000 *2 | 4,000 *2 | 2,300 | 1,400 | |
6° | E32-T51 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Reflective models with integrated lens |
Top-view | 4° | E32-D16 2M | 40 to 2,800 |
40 to 1,400 |
40 to 900 | 40 to 480 |
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View Models
Sensing method |
Sensing direction |
Aperture angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through-beam | Side-view | 1.5° | E32-A03 2M | 3,220 | 1,780 | 1,200 | 500 |
E32-A03-1 2M | |||||||
3.4° | E32-A04 2M | 1,280 | 680 | 450 | 200 | ||
4° | E32-T24SR 2M | 4,000 * | 2,200 | 1,460 | 580 | ||
E32-T24S 2M | 4,000 * | 2,600 | 1,740 | 700 | |||
E32-T22S 2M | 4,000 * | 3,800 | 2,500 | 1,000 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Models for Detection without Background Interference
Sensing method |
Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high-speed mode |
|||
Limited- reflective |
Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-L24S 2M | 0 to 4 | |||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
Transparent Object Detection (Retro-reflective Models)
Sensing method |
Feature | Size | Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Retro- reflective |
Film detection | M3 | E32-C31 2M +E39-F3R +E39-RP37 |
250 | 200 | — | |
Square | — | E32-R16 5M | 150 to 1,500 | ||||
Threaded | M6 | E32-R21 2M | 10 to 250 | ||||
Hex-shaped | E32-LR11NP 2M +E39-RP1 |
1,350 | 1,200 | 1,000 | 550 |
Transparent Object Detection (Limited-reflective Models)
Sensing method |
Feature | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode |
Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Limited- reflective |
Small size | Flat-view | E32-L24S 2M | 0 to 4 | |||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||||
Glass substrate alignment, 70°C |
E32-A08 2M | 10 to 20 | — | ||||
Standard/long-distance | E32-A12 2M | 12 to 30 | — | ||||
Side-view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
Glass substrate mapping, 70°C |
Top-view | E32-A09 2M | 15 to 38 | — |
Chemical-resistant, Oil-resistant Models
Sensing method |
Type | Sensing direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through- beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 2,200 |
Chemical/ oil-resistant |
Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,600 | |
E32-T11F 2M | 4,000 *1 | 4,000 *1 | 2,600 | 1,000 | |||
Side-view | E32-T14F 2M | 1,400 | 800 | 500 | 200 | ||
Chemical/ oil-resistant at 150°C |
Top-view | E32-T51F 2M | 4,000 *1 | 2,800 | 1,800 | 700 | |
Reflective | Semiconductors: Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
|||
Semiconductors: Resist stripping; 85°C |
E32-L11FS 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
|||||
Chemical/ oil-resistant |
E32-D12F 2M | — *2 | 190 | 130 | 60 | ||
Chemical- resistant cable |
E32-D11U 2M | 840 | 350 | 240 | 100 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Bending-resistant Models
Sensing method |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high-speed mode |
|||
Through-beam | 1.5 dia. | E32-T22B 2M | 680 | 400 | 220 | 90 |
M3 | E32-T21 2M | |||||
M4 | E32-T11 2M | 2,500 | 1,350 | 900 | 360 | |
Square | E32-T25XB 2M | 500 | 300 | 170 | 70 | |
Reflective | 1.5 dia. | E32-D22B 2M | 140 | 60 | 40 | 16 |
M3 | E32-D21 2M | |||||
3 dia. | E32-D221B 2M | 300 | 140 | 90 | 40 | |
M4 | E32-D21B 2M | |||||
M6 | E32-D11 2M | 840 | 350 | 240 | 100 | |
Square | E32-D25XB 2M | 240 | 100 | 60 | 30 |
Heat-resistant Models
Sensing method |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode |
Super-high- speed mode |
|||
Through-beam | 100°C | E32-T51R 2M | 1,600 | 800 | 560 | 225 |
150°C | E32-T51 2M | 2,800 | 1,500 | 1,000 | 400 | |
200°C | E32-T81R-S 2M | 1,000 | 550 | 360 | 140 | |
350°C | E32-T61-S 2M | 1,680 | 900 | 600 | 240 | |
Reflective | 100°C | E32-D51R 2M | 670 | 280 | 190 | 80 |
150°C | E32-D51 2M | 1,120 | 450 | 320 | 144 | |
200°C | E32-D81R-S 2M | 420 | 180 | 120 | 54 | |
300°C | E32-A08H2 2M | 10 to 20 | — | |||
E32-A09H2 2M | 20 to 30 (center 25) | — | ||||
350°C | E32-D611-S 2M | 420 | 180 | 120 | 54 | |
E32-D61-S 2M | ||||||
400°C | E32-D73-S 2M | 280 | 120 | 80 | 36 |
Area Detection Models
Sensing method |
Type | Sensing width | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Through-beam | Area | 11 mm | E32-T16PR 2M | 3,100 | 1,700 | 1,120 | 440 |
E32-T16JR 2M | 2,750 | 1,500 | 960 | 380 | |||
30 mm | E32-T16WR 2M | 4,000 | 2,600 | 1,700 | 680 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 700 | 300 | 200 | 90 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection Models
Sensing method |
Tube diameter |
Feature | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Tube- mounting |
3.2, 6.4, or 9.5 dia |
Stable residual quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
|||
8 to 10 dia | Mounting at multiple levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm |
||||
No restrictions |
Large tubes | E32-D36T 5M | Applicable tube: Transparent tube (no restrictions on diameter) |
||||
Liquid contact (heat-resistant up to 200°C) |
— | — | E32-D82F1 4M | Liquid-contact type |
Vacuum-resistant Models
Sensing method |
Heat-resistant temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
|||
Through-beam | 120 °C | E32-T51V 1M | 720 | 400 | 260 | 100 |
E32-T51V 1M+E39-F1V | 2,000 * | 2,000 * | 1,360 | 520 | ||
200 °C | E32-T84SV 1M | 1,760 | 950 | 640 | 260 |
* The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Models for FPD, Semiconductors, and Solar Cells
Sensing method |
Application | Operating temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode |
High-speed mode |
Super-high- speed mode |
||||
Limited- reflective |
Glass presence detection |
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-A08 2M | 10 to 20 | — | |||||
Glass substrate alignment |
300°C | E32-A08H2 3M | |||||
70°C | E32-A12 2M | 12 to 30 | — | ||||
Glass substrate mapping |
E32-A09 2M | 15 to 38 | — | ||||
300°C | E32-A09H2 2M | 20 to 30 (center 25) | — | ||||
Wet processes: Cleaning, Resist developing and etching |
60°C | E32-L11FP 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
||||
Wet process: Resist stripping |
85°C | E32-L11FS 5M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
||||
Through- beam |
Wafer mapping | 70°C | E32-A03 2M | 3,220 | 1,780 | 1,200 | 500 |
E32-A03-1 2M | |||||||
E32-A04 2M | 1,280 | 680 | 450 | 200 | |||
E32-T24SR 2M | 4,000 * | 2,200 | 1,460 | 580 | |||
E32-T24S 2M | 4,000 * | 2,600 | 1,740 | 700 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Dimensions | Fiber Amplifier Sensor – E3X-HD series
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Pre-wired Amplifier Units
E3X-HD11
E3X-HD41
Amplifier Units with Wire-saving Connectors
E3X-HD6
E3X-HD8
Amplifier Units with M8 Connectors
E3X-HD14
E3X-HD44
Amplifier Unit with Connector for Sensor Communications Unit
E3X-HD0
คุณสมบัติ | Fiber Amplifier Sensor – E3X-HD series
- มาพร้อมกับ Smart Tuning ซึ่งกำหนดการตั้งค่าโดยอัตโนมัติให้เป็นค่าที่เหมาะสมที่สุดด้วยการกดปุ่มเพียงปุ่มเดียว
- การออกแบบที่ใช้งานได้สูงช่วยให้ทุกคนสามารถกำหนดการตั้งค่าได้อย่างง่ายดาย
- ตรวจจับสิ่งสกปรก, การสั่นสะเทียน, และการเสื่อมสภาพของ LED, และชดเชยระดับเหตุการณ์และความเข้มข้นของแสงโดยอัตโนมัติ
- พลังที่ดีที่สุดในระดับที่ไม่มีใครเทียบให้การตรวจจับที่มั่นคงสำหรับชื้นงานที่มีการสะท้อนแสงต่ำและชิ้นงานขนาดใหญ่ (ติดตั้ง GIGA RAY II)
คุณสมบัติ | Fiber Amplifier Sensor – E3X-HD series
Fiber Unit Amplifier Sensor | E3X-HD series |
---|---|
แรงดันไฟฟ้า | 12 – 24 VDC |
การใช้พลังงาน |
สูงสุด 720 มิลลิวัตต์ |
หน่วยเชื่อมต่อสูงสุด | 16 ยูนิต |
ระดับการป้องกัน | IEC 60529 IP50 |
วัสดุ | โพลีคาร์บอเนต (PC) |