OMRON Fiber Sensor - E3X-SD / NA series
OMRON Fiber Amplifier – E3X-SD / NA series
Model Numbers | Fiber Amplifier Sensor – E3X-SD / NA series
Fiber Amplifier Units
Digital Display and Direct Key Setting
Item | Appearance | Connection method | Ratings and Specifications |
Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Standard models | Pre-wired (2 m) | — | E3X-SD21 2M | E3X-SD51 2M | |
Wire-saving connector | E3X-SD7 | E3X-SD9 |
*An Amplifier Unit Connector (sold separately) is required.
Bar Display and Adjuster Setting
Item | Appearance | Connection method | Ratings and Specifications |
Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Standard models | Pre-wired (2 m) | — | E3X-NA11 2M | E3X-NA41 2M | |
Wire-saving connector | E3X-NA6 | E3X-NA8 | |||
High-speed detection models |
Pre-wired (2 m) | Response time: 20 μs |
E3X-NA11F 2M | E3X-NA41F 2M | |
Water-resistant models |
Pre-wired (2 m) | Degree of protection: IP66 |
E3X-NA11V 2M | E3X-NA41V 2M | |
Connector (M8) | E3X-NA14V | E3X-NA44V |
*1. An Amplifier Unit Connector (sold separately) is required.
*2. A Sensor I/O Connector (sold separately) is required.
Accessories (sold separately)
Amplifier Unit Connectors (Required for models for Wire-saving Connectors.)
Note: Protective seals provided.
Item | Appearance | Cable length | No. of conductors | Model |
---|---|---|---|---|
Master Connector | 2 m | 3 | E3X-CN11 | |
Slave Connector | 1 | E3X-CN12 |
Ordering Precautions for Amplifier Units Connectors
A Connector is not provided with the Amplifier Unit.
Refer to the tables at the right when placing an order.
Fiber Amplifier Units | Applicable Connectors (sold separately) | |||
---|---|---|---|---|
Type | NPN | PNP | Master Connector | Slave Connector |
Standard models | E3X-SD7 | E3X-SD9 | E3X-CN11 (3-wire) | E3X-CN12 (1-wire) |
E3X-NA6 | E3X-NA8 |
When Using 5 Amplifier Units
5 Fiber Amplifier Units | + | 1 Master Connector + 4 Slave Connectors |
Sensor I/O Connectors (Required for models with M8 Connectors.)
(Models for Connectors: A Connector is not provided with the Amplifier Unit. Be sure to order a Connector separately.)
Size | Cable specifications | Appearance | Cable type | Model | ||
---|---|---|---|---|---|---|
M8 | Standard cable | Straight connector | 2 m | Four-conductor cable | XS3F-M421-402-A | |
5 m | XS3F-M421-405-A | |||||
L-shaped connector | 2 m | XS3F-M422-402-A | ||||
5 m | XS3F-M422-405-A |
Mounting Brackets
A Mounting Bracket is not provided with the Fiber Amplifier Unit. Order a Mounting Bracket separately if required.
Appearance | Applicable models | Model | Quantity |
---|---|---|---|
E3X-SD[]E3X-NA[]E3X-NA[]F | E39-L143 | 1 | |
E3X-NA[]V | E39-L148 |
End Plate
End Plates are not provided with the Fiber Amplifier Unit. Order End Plates separately if required.
Appearance | Model | Quantity |
---|---|---|
PFP-M | 1 |
Specifications | Fiber Amplifier Sensor – E3X-SD / NA series
Fiber Amplifier Units
Type | Digital display and direct key setting |
Bar display and adjuster setting | |||
---|---|---|---|---|---|
Standard models | Standard models |
High-speed detection models |
Water-resistant models |
||
Model | E3X-SD[] | E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |
Light source (wavelength) |
Red, 4-element LED (625 nm) | Red, 4-element LED (624 nm) |
Red, 4-element LED (625 nm) |
Red LED (680 nm) | |
Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p): 10% max. | ||||
Power consumption/ Current consumption |
At Power Supply Voltage of 24 VDC 960 mW max./40 mA max. At Power Supply Voltage of 12 VDC 960 mW max./80 mA max. |
At Power Supply Voltage of 24 VDC 840 mW max./35 mA max. At Power Supply Voltage of 12 VDC 420 mW max./35 mA max. |
|||
Control output | Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.) Light-ON/Dark-ON mode selector |
Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1 V max.) Light-ON/Dark-ON mode selector. |
|||
Response time | Operate or reset: 200 μs max. *1 | Operate: 20 μs max. Reset: 30 μs max. |
Operate or reset: 200 μs max. *1 |
||
Sensitivity adjustment | UP/DOWN direct key setting, teaching with/without a workpiece, automatic teaching |
8-turn sensitivity adjuster (with indicator) | |||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection |
Power supply reverse polarity protection, output short-circuit protection |
|||
Timer function | — | No timer, OFF-delay timer; or Timer selector (timer time: 40 ms (fixed)) |
|||
Mutual interference prevention |
Up to 5 Amplifiers (optically synchronized) *2 | None | Up to 5 Amplifiers (optically synchronized) *2 |
||
Ambient illumination | Receiver side Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. |
||||
Number of gang- mounted Amplifiers |
16 max. (The ambient temperature specification depends on the number of gang-mounted Amplifiers.) |
||||
Ambient temperature range |
Operating: Groups of 1 to 3 Amplifiers: – 25 °C to 55 °C Groups of 4 to 11 Amplifiers: – 25 °C to 50 °C Groups of 12 to 16 Amplifiers: – 25 °C to 45 °C Storage: – 30 °C to 70 °C (with no icing or condensation) |
||||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) |
Operating: 35% to 85% Storage: 35% to 95% (with no condensation) |
|||
Insulation resistance | 20 MΩ. min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute *3 | ||||
Vibration resistance | Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
||||
Shock resistance | Destruction: 500 m/s2, for 3 times each in X, Y and Z directions | ||||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | IEC 60529 IP66 (with Protective Cover attached) |
|||
Connection method | Pre-wired (standard cable length: 2 m), or connector | ||||
Weight (packed state) *4 | Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g | ||||
Material | Case | Polybutylene terephthalate (PBT) | |||
Cover | Polycarbonate (PC) | Polyethersulfone (PES) |
|||
Accessories | Instruction manual |
Amplifier Unit Connectors (Wire-saving Connectors)
Model | E3X-CN11 | E3X-CN12 | |
---|---|---|---|
Rated current | 2.5 A | ||
Rated voltage | 50 V | ||
Contact resistance | 20 mΩ max. (20 mVDC max., 100 mA max.) (The above figure is for connection to the Fiber Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) |
||
Number of insertions | Destruction: 50 times (for connection to the Fiber Amplifier Unit and the adjacent Connector) | ||
Material | Housing | Polybutylene terephthalate (PBT) | |
Contact | Phosphor bronze/gold-plated nickel | ||
Weight (packed state) | Approx. 55 g | Approx. 25 g |
Sensing distance
Threaded Models
Detection method | Sensing direction | Size | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | Right-angle | M4 | E32-T11N 2M | 530 | 160 | 280 |
E32-LT11N 2M | 1,800 | 600 | 900 | |||
Straight | E32-T11R 2M | 560 | 160 | 280 | ||
E32-LT11 2M | 2,100 | 700 | 1,050 | |||
E32-LT11R 2M | 1,800 | 600 | 900 | |||
Reflective | Right-angle | M3 | E32-C31N 2M | 25 | 7.5 | 13 |
E32-C21N 2M | 65 | 21 | 32 | |||
M4 | E32-D21N 2M | 170 | 56 | 85 | ||
M6 | E32-C11N 2M | 170 | 50 | 85 | ||
E32-LD11N 2M | 170 | 56 | 85 | |||
Straight | M3 | E32-D21R 2M | 30 | 10 | 15 | |
E32-C31 2M | 80 | 26 | 40 | |||
E32-C31M 1M | ||||||
M4 | E32-D211R 2M | 30 | 10 | 15 | ||
M6 | E32-D11R 2M | 180 | 60 | 90 | ||
E32-CC200 2M | 300 | 100 | 150 | |||
E32-LD11 2M | 180 | 60 | 90 | |||
E32-LD11R 2M | 170 | 56 | 85 |
Cylindrical Models
Detection method | Size | Sensing direction | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | 1 dia. | Top-view | E32-T223R 2M | 120 | 36 | 60 |
1.5 dia. | E32-T22B 2M | 200 | 60 | 100 | ||
3 dia. | E32-T12R 2M | 560 | 160 | 280 | ||
Side-view | E32-T14LR 2M | 220 | 66 | 110 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 30 | 10 | 15 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 6 | 2 | 3 | ||
3 dia. | E32-D22R 2M | 30 | 10 | 15 | ||
E32-D221B 2M | 70 | 20 | 35 | |||
E32-D32L 2M | 160 | 50 | 80 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 16 | 4 | 10 |
Flat Models
Detection method | Sensing direction | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | Top-view | E32-T15XR 2M | 560 | 160 | 280 |
Side-view | E32-T15YR 2M | 220 | 66 | 110 | |
Flat-view | E32-T15ZR 2M | ||||
Reflective | Top-view | E32-D15XR 2M | 180 | 60 | 90 |
Side-view | E32-D15YR 2M | 40 | 10 | 20 | |
Flat-view | E32-D15ZR 2M |
Sleeve Models
Detection method | Sensing direction | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | Side-view | E32-T24R 2M | 60 | 18 | 30 |
E32-T24E 2M | 180 | 36 | 60 | ||
Top-view | E32-T21-S1 2M | 130 | 43 | 65 | |
E32-T33 1M | 40 | 13.5 | 20 | ||
E32-TC200BR 2M | 560 | 160 | 280 | ||
Reflective | Side-view | E32-D24R 2M | 14 | 4.6 | 7 |
E32-D24-S2 2M | 26 | 8 | 13 | ||
Top-view | E32-D43M 1M | 6 | 2 | 3 | |
E32-D331 2M | 3 | 1 | 1.5 | ||
E32-D33 2M | 16 | 4 | 10 | ||
E32-D32-S1 0.5M | 14 | 4 | 7 | ||
E32-D31-S1 0.5M | |||||
E32-DC200F4R 2M | 30 | 10 | 15 | ||
E32-D22-S1 2M | 57 | 19 | 28 | ||
E32-D21-S3 2M | |||||
E32-DC200BR 2M | 180 | 60 | 90 | ||
E32-D25-S3 2M | 57 | 19 | 28 |
Small-spot, Reflective
Type | Spot diameter |
Center distance (mm) |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Variable spot |
0.1 to 0.6 dia. |
6 to 15 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | ||
0.3 to 1.6 dia. |
10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | |||
Parallel light |
4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | ||
E32-C31N 2M + E39-F3C | ||||||
Integrated lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | ||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | |||
Small- spot |
0.1 dia. | 7 | E32-C41 1M + E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | ||
0.5 dia. | E32-C31 2M + E39-F3A-5 | Spot diameter of 0.5 mm at 5 mm. | ||||
E32-C31N 2M + E39-F3A-5 | ||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | |||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | ||||
E32-C31N 2M + E39-F3B | ||||||
3 dia. | 50 | E32-CC200 2M + E39-F18 | Spot diameter of 3 mm at 50 mm. | |||
E32-C11N 2M + E39-F18 |
High-power Beam
Type | Sensing direction |
Aperture angle |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam Integrated lens |
Right-angle | 15° | E32-LT11N 2M | 1,800 | 600 | 900 |
Top-view | 10° | E32-T17L 10M | 20,000 *1 | 8,400 | 14,000 | |
15° | E32-LT11 2M | 2,100 | 700 | 1,050 | ||
15° | E32-LT11R 2M | 1,800 | 600 | 900 | ||
Side-view | 30° | E32-T14 2M | 3,600 | 1,080 | 1,800 | |
Through-beam models with lenses |
Right-angle | 12° | E32-T11N 2M + E39-F1 | 3,700 | 1,110 | 2,100 |
6° | E32-T11N 2M + E39-F16 | 4,000 *2 | 2,000 | 3,600 | ||
Top-view | 12° | E32-T11R 2M + E39-F1 | 4,000 *2 | 1,260 | 2,100 | |
6° | E32-T11R 2M + E39-F16 | 4,000 *2 | 2,000 | 3,600 | ||
Side-view | 60° | E32-T11R 2M + E39-F2 | 440 | 130 | 220 | |
Top-view | 12° | E32-T11 2M + E39-F1 | 4,000 *2 | 1,200 | 2,000 | |
6° | E32-T11 2M + E39-F16 | 4,000 *2 | 2,600 | 4,000 *2 | ||
Side-view | 60° | E32-T11 2M + E39-F2 | 720 | 200 | 360 | |
Top-view | 12° | E32-T51R 2M + E39-F1 | 2,000 | 720 | 1,650 | |
6° | E32-T51R 2M + E39-F16 | 4,000 *2 | 1,560 | 2,900 | ||
Side-view | 60° | E32-T51R 2M + E39-F2 | 360 | 120 | 200 | |
Top-view | 12° | E32-T81R-S 2M + E39-F1 | 1,800 | 630 | 1,100 | |
6° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 1,300 | 2,300 | ||
Side-view | 60° | E32-T81R-S 2M + E39-F2 | 280 | 84 | 140 | |
Top-view | 12° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 1,800 | 3,000 | |
6° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 2,340 | 3,900 | ||
Side-view | 60° | E32-T61-S 2M + E39-F2 | 780 | 260 | 390 | |
Top-view | 12° | E32-T51 2M + E39-F1-33 | 2,400 | 720 | 1,400 | |
6° | E32-T51 2M + E39-F16 | 4,000 *2 | 3,120 | 4,000 *2 | ||
Reflective Integrated lens |
Top-view | 4° | E32-D16 2M | 800 | 140 | 40 to 400 |
Narrow View
Detection method | Sensing direction |
Aperture angle | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | Side-view | 1.5° | E32-A03 2M | 890 | 267 | 445 |
E32-A03-1 2M | ||||||
3.4° | E32-A04 2M | 340 | 102 | 170 | ||
4° | E32-T24SR 2M | 1170 | 360 | 600 | ||
E32-T24S 2M | 1400 | 420 | 700 | |||
E32-T22S 2M | 2000 | 600 | 1000 |
Detection without Background Interference
Detection method |
Sensing direction |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Limited- reflective |
Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | 0 to 15 |
E32-L24S 2M | 0 to 4 | ||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | 5.4 to 8 (center 7.2) | 5.4 to 9 (center 7.2) |
Transparent Object Detection (Retro-reflective)
Detection method |
Feature | Size | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Retroreflective Sensors |
Film detection | M3 | E32-C31 2M + E39-F3R + E39-RP37 |
220 | 50 | 75 |
Square | – | E32-R16 2M | 1,500 | 1,000 | 150 to 1,500 | |
Threaded Models | M6 | E32-R21 2M | 10 to 250 | 250 | 10 to 250 | |
Hex-shaped | E32-LR11NP 2M + E39-RP1 |
600 | 200 | 300 |
Transparent Object Detection (Limited-reflective)
Detection method |
Feature | Sensing direction |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Retro- reflective |
Small size | Flat-view | E32- L24S 2M | 0 to 4 | ||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | 0 to 15 | ||
Glass substrate alignment, 70°C |
E32-A08 2M | 10 to 20 | ||||
Standard/ long-distance |
E32-A12 2M | 12 to 30 | – | – | ||
Side view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
5.4 to 8 (center 7.2) |
5.4 to 9 (center 7.2) |
|
Glass substrate mapping, 70°C |
Top-view | E32-A09 2M | 15 to 38 (center 25) |
Chemical-resistant, Oil-resistant
Detection method |
Type | Sensing direction |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through- beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 * | 1,400 | 2,400 |
Chemical/ oil-resistant |
Top-view | E32-T12F 2M | 3,200 | 960 | 1,600 | |
E32-T11F 2M | 2,100 | 760 | 1,050 | |||
Side-view | E32-T14F 2M | 400 | 120 | 200 | ||
Chemical/oil- resistant at 150°C |
Top-view | E32-T51F 2M | 1,400 | 400 | 700 | |
Reflective | Semiconductors: Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
||
Semiconductors: Resist stripping; 85°C |
E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
||||
Chemical/ oil-resistant |
E32-D12F 2M | 100 | 32 | 50 | ||
Chemical-resistant cable |
E32-D11U 2M | 180 | 60 | 90 |
*The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Bending-resistant
Detection method | Size | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | 1.5 dia. | E32-T22B 2M | 200 | 60 | 100 |
M3 | E32-T21 2M | ||||
M4 | E32-T11 2M | 720 | 200 | 360 | |
Square | E32-T25XB 2M | 150 | 40 | 75 | |
Reflective | 1.5 dia. | E32-D22B 2M | 30 | 10 | 15 |
M3 | E32-D21 2M | ||||
3 dia. | E32-D221B 2M | 70 | 20 | 35 | |
M4 | E32-D21B 2M | ||||
M6 | E32-D11 2M | 180 | 60 | 90 | |
Square | E32-D25XB 2M | 50 | 16 | 25 |
Heat-resistant
Detection method | Heat-resistant temperature | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | 100°C | E32-T51R 2M | 400 | 120 | 225 |
150°C | E32-T51 2M | 800 | 240 | 400 | |
200°C | E32-T81R-S 2M | 360 | 100 | 180 | |
350°C | E32-T61-S 2M | 600 | 180 | 300 | |
Reflective | 100°C | E32-D51R 2M | 140 | 42 | 70 |
150°C | E32-D51 2M | 240 | 80 | 120 | |
200°C | E32-D81R 2M | 90 | 27 | 45 | |
300°C | E32-A08H2 2M | 10 to 20 | |||
E32-A09H2 2M | 20 to 30 (center 25) | ||||
350°C | E32-D61 2M | 90 | 27 | 45 | |
400°C | E32-D73 2M | 60 | 18 | 30 |
Area Beam
Detection method | Type | Sensing width | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Through-beam | Area | 11 mm | E32-T16PR 2M | 800 | 260 | 450 |
E32-T16JR 2M | 700 | 220 | 390 | |||
30 mm | E32-T16WR 2M | 1380 | 400 | 690 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 150 | 50 | 75 |
Liquid-level Detection
Detection method |
Pipe diameter |
Feature | Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Tube-mounting | 3.2/6.4/ 9.5 dia. |
Stable residual quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
||
8 to 10 dia. | Mounting at multi levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm |
|||
No re- strictions |
Large tubes | E32-D36T 2M | Applicable tube: Transparent tube (no restrictions on diameter) |
|||
Liquid contact (heat-resistant up to 200°C) |
– | – | E32-D82F1 4M | Liquid-contact model |
Vacuum-resistant
Detection method | Heat-resistant temperature |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | |||
Through-beam | 120°C | E32-T51V 1M | 200 | – | 100 |
E32-T51V 1M + E39-F1V | 1200 | – | 600 | ||
200°C | E32-T84SV 1M | 500 | – | 250 |
FPD, Semiconductors, and Solar Cells
Detection method |
Application | Operating temperature |
Model | Sensing distance (mm) | ||
---|---|---|---|---|---|---|
E3X-SD[]E3X-NA[] | E3X-NA[]F | E3X-NA[]V | ||||
Limited- reflective |
Glass presence detection |
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | 0 to 15 |
Glass substrate alignment |
E32-A08 2M | 10 to 20 | ||||
300°C | E32-A08H2 2M | |||||
70°C | E32-A12 2M | 12 to 30 | – | – | ||
Glass substrate mapping |
E32-A09 2M | 15 to 38 (center 25) | ||||
300°C | E32-A09H2 2M | 20 to 30 (center 25) | ||||
Wet processes: Cleaning, Resist developing and etching |
60°C | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
|||
Wet process: Resist stripping |
85°C | E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
|||
Through- beam |
Wafer mapping | 70°C | E32-A03 2M | 890 | 267 | 445 |
E32-A03-1 2M | ||||||
E32-A04 2M | 340 | 102 | 170 | |||
E32-T24SR 2M | 1170 | 360 | 600 | |||
E32-T24S 2M | 1400 | 420 | 700 |
Dimensions | Fiber Amplifier Sensor – E3X-SD / NA series
Fiber Amplifier Units
Amplifier Units with Cables
E3X-SD21, E3X-SD51
E3X-NA11, E3X-NA11F
E3X-NA41, E3X-NA41F
* There is no hole for E3X-NA[]F models.
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Fiber Amplifier Units if they are
mounted side by side.
Amplifier Units with Connectors
E3X-SD7, E3X-SD9
E3X-NA6, E3X-NA8
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Fiber Amplifier Units if they are mounted side by side.
Amplifier Units with Cables, Water-resistant Models
E3X-NA11V
E3X-NA41V
Amplifier Units with Connectors, Water-resistant Models
E3X-NA14V
E3X-NA44V
Amplifier Unit Connectors (Wire-saving Connectors)
Master Connector
E3X-CN11
* E3X-CN11: 4 dia. cable / 3 conductors/Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Slave Connector
E3X-CN12
* E3X-CN12: 2.6 dia. cable / 1 conductor/Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Accessories (sold separately)
Mounting Brackets
E39-L143
Material: Stainless steel (SUS304)
End Plates
PFP-M
คุณสมบัติ | Fiber Amplifier Sensor – E3X-SD / NA series
- ไฟเบอร์แอมพลิฟายเออร์ยูนิตที่เรียบง่ายและราคาไม่แพง
- ใช้คุณสมบัติปุ่มเดียวเพื่อความเร็ว, ใช้งานง่าย
คุณสมบัติ | Fiber Amplifier Sensor – E3X-SD / NA series
Fiber Amplifier Sensor | E3X-SD / NA series |
---|---|
แรงดันไฟฟ้า | 12 – 24 VDC ± 10% |
การใช้พลังงาน | ที่แรงดันไฟฟ้าของแหล่งจ่ายไฟ 24 VDC สูงสุด 960 มิลลิวัตต์ / สูงสุด 40 มิลลิแอมป์ |
ที่แรงดันไฟฟ้าของแหล่งจ่ายไฟ 12 VDC สูงสุด 960 มิลลิวัตต์ / สูงสุด 80 มิลลิแอมป์ |
|
เวลาตอบสนอง | การใช้งานหรือรีเซ็ต สูงสุด 200 ไมโครวินาที |
ระดับการป้องกัน | IEC 60529 IP50 |
วิธีการเชื่อมต่อ | มีสาย, Connector |
วัสดุ | โพลีบิวทิลีนเทเรฟทาเลต (PBT |