OMRON Limit Switches – ZC-[]55
Model Numbers | Limit Switches – ZC-[]55
List of Models
Actuator | Model | Approved Standards | |||
---|---|---|---|---|---|
UL | CSA | EN | |||
Plunger | ZC-D55 | ● | ● | ● | |
Panel mount plunger | ZC-Q55 | ● | ● | ● | |
Panel mount roller plunger | ZC-Q2255 | ● | ● | ● | |
Panel mount crossroller plunger | ZC-Q2155 | ● | ● | ● | |
Sealed roller plunger | ZC-N2255 | ● | ● | ● | |
Sealed crossroller plunger | ZC-N2155 | ● | ● | ● | |
Short hinge lever | ZC-W55 | ● | ● | ● | |
Hinge lever | ZC-W155 | ● | ● | ● | |
Short hinge roller lever | ZC-W255 | ● | ● | ● | |
Hinge roller lever | ZC-W2155 | ● | ● | ● | |
One-way action short hinge roller lever | ZC-W355 | ● | ● | ● | |
One-way action hinge roller lever | ZC-W3155 | ● | ● | ● |
Note:Note:
1. Use molded terminal models when using the Switch under one of the following conditions:a) dusty, b) high amount of dripping oil, or c) high humidity.
2. Models are available with lead outlets in three positions: right-hand, left-hand, and underside.
Specifications | Limit Switches – ZC-[]55
Ratings
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC |
10 10 |
3 2.5 |
1.5 1.25 |
10 10 |
5 3 |
2.5 1.5 |
||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
10 10 6 0.5 0.25 |
3 3 3 0.4 0.2 |
1.5 1.5 1.5 0.4 0.2 |
6 6 5 0.05 0.03 |
5 5 5 0.05 0.03 |
2.5 2.5 2.5 0.05 0.03 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 15 A max. |
Note:The above figures are for steady-state currents.
Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
Note:Lamp load has an inrush current of 10 times the steady-state current.
Note:Motor load has an inrush current of 6 times the steady-state current.
Note:The above ratings were tested under the following conditions according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.
Characteristics
Degree of protections | IP67 | |
---|---|---|
Durability | Mechanical | 10,000,000 operations min. |
Electrical | 500,000 operations min. | |
Operating speed | 0.05 mm/s to 0.5 m/s *1 | |
Operating frequency |
Mechanical | 120 operations/min |
Electrical | 20 operations/min | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value for the builtin switch when tested alone) | |
Dielectric strength |
Between non-continuous terminals | 1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and non- current-carrying metal parts |
2,000 VAC, 50/60 Hz for 1 min | |
Rated insulation voltage (Ui) | 1,000 VAC | |
Pollution degree (operating environment) | 3 (IEC947-5-1) | |
Short-circuit protective device | 10 A-fuse type gG (IEC 60269) | |
Protection against electric shock | Class II | |
Proof tracking index (PTI) | 175 | |
Switch category | D (IEC335) | |
Rated operating current (Ie) | 10 A | |
Rated operating voltage (Ue) | 250 VAC | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock resistance |
Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. (in case of plunger model) *1 *2 | |
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 92 g (in case of ZC-Q22(21)55) |
Note:Only for models with plungers. (Contact your OMRON representative for information on other models.)
Note:Less than 1 ms under a free state at the operating limits.
Dimensions | Limit Switches – ZC-[]55
Plunger
ZC-D55
Panel Mount Plunger
ZC-Q55
Panel Mount Roller Plunger
ZC-Q2255
Panel Mount Crossroller Plunger
ZC-Q2155
Sealed Roller Plunger
ZC-N2255
Sealed Crossroller Plunger
ZC-N2155
Short Hinge Roller Lever
ZC-W55
Hinge Lever
ZC-W155
Short Hinge Roller Lever
ZC-W255
Hinge Roller Lever
ZC-W2155
One-way Action Short Hinge Roller Lever
ZC-W355
One-way Action Hinge Roller Lever
ZC-W3155
Note:Note:
1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Operating characteristics are for when the Switch is operated from direction A.
Features | Limit Switches – ZC-[]55
A limit switch with high repeatability and durability. Utilizes 25.4 mm mounting hole pattern.
- Requires less operating force than conventional limit switches
- Lineup includes modes with operation indicators for easy maintenance and inspection
Properties | Limit Switches – ZC-[]55
Limit Switches | ZC-[]55 | |
---|---|---|
Switching standard loads | 10A | 250 VAC |
1A | 30 VDC | |
Life expectancy | 500,000 operations min. | |
Size | 25.4 mm |