OMRON Power Supplies - S8VK-G
Model Numbers | Power Supplies – S8VK-G
Model Number Structure
Model Number Legend
Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below.
Ordering Information
Note: For details on normal stock models, contact your nearest OMRON representative.
Power ratings | Input voltage | Output Voltage (VDC) |
Output current | Boost Current | Model number |
---|---|---|---|---|---|
15 W | Single phase 100 to 240 VAC 90 to 350 VDC |
5 V | 3 A | 3.6 A | S8VK-G01505 |
12 V | 1.2 A | 1.44 A | S8VK-G01512 | ||
24 V | 0.65 A | 0.78 A | S8VK-G01524 | ||
30 W | 5 V | 5 A | 6 A | S8VK-G03005 | |
12 V | 2.5 A | 3 A | S8VK-G03012 | ||
24 V | 1.3 A | 1.56 A | S8VK-G03024 | ||
60 W | 12 V | 4.5 A | 5.4 A | S8VK-G06012 | |
24 V | 2.5 A | 3 A | S8VK-G06024 | ||
120 W | 24 V | 5 A | 6 A | S8VK-G12024 | |
240 W | 24 V | 10 A | 12 A | S8VK-G24024 | |
48 V | 5 A | 6 A | S8VK-G24048 | ||
480 W | 24 V | 20 A | 24 A | S8VK-G48024 | |
48 V | 10 A | 12 A | S8VK-G48048 |
Mounting Brackets
Name | Model |
---|---|
Front-mounting bracket (for 15, 30 and 60 W models) | S82Y-VS10F |
Front-mounting bracket (for 120, 240 and 480 W models) | S82Y-VK10F |
Side-mounting bracket (for 15 W models) | S82Y-VK15P |
Side-mounting bracket (for 30 and 60 W models) | S82Y-VS10S |
Side-mounting bracket (for 120 W models) | S82Y-VK10S |
Side-mounting bracket (for 240 W models) | S82Y-VK20S |
Note: Be sure to use the accessory screws.
Mounting screw tightening torque (recommended): 4.43 to 5.31 lb-in (0.5 to 0.6 N·m)
Specifications | Power Supplies – S8VK-G
Ratings, Characteristics, and Functions
Power rating | 15 W | 30 W | ||||||
---|---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 24 V | 5 V | 12 V | 24 V | ||
Efficiency | 230 VAC input *6 |
77% typ. | 77% typ. | 80% typ. | 79% typ. | 82% typ. | 86% typ. | |
Input | Voltage range *1 | Single-phase, 85 to 264 VAC, 90 to 350 VDC *10 | ||||||
Frequency *1 | 50/60 Hz (47 to 450 Hz) | |||||||
Current | 115 VAC input *6 |
0.32 A typ. | 0.3 A typ. | 0.31 A typ. | 0.5 A typ. | 0.57 A typ. | 0.58 A typ. | |
230 VAC input *6 |
0.2 A typ. | 0.21 A typ. | 0.2 A typ. | 0.32 A typ. | 0.37 A typ. | 0.36 A typ. | ||
Power factor | 230 VAC input, 100% load |
0.42 min. | 0.43 min. | 0.42 min. | 0.43 min. | |||
Leakage current |
115 VAC input | 0.14 mA typ. | 0.13 mA typ. | |||||
230 VAC input | 0.25 mA typ. | 0.24 mA typ. | ||||||
Inrush current *2 (for a cold start at 25°C) |
115 VAC input | 16 A typ. | 16 A typ. | |||||
230 VAC input | 32 A typ. | 32 A typ. | ||||||
Output | Rated output current | 3 A | 1.2 A | 0.65 A | 5 A | 2.5 A | 1.3 A | |
Boost current | 3.6 A | 1.44 A | 0.78 A | 6 A | 3 A | 1.56 A | ||
Voltage adjustment range *3 | -10% to 15% (with V.ADJ) (guaranteed) | |||||||
Ripple & Noise voltage *4 |
100 to 240 VAC input, 100% load *6 |
60 mVp-p max. at 20 MHz of bandwidth |
50 mVp-p max.at 20 MHz of bandwidth |
30 mVp-p max. at 20 MHz of bandwidth |
30 mVp-p max. at 20 MHz of bandwidth |
30 mVp-p max. at 20 MHz of bandwidth |
30 mVp-p max. at 20 MHz of bandwidth |
|
Input variation influence *8 | 0.4% max. | 0.4% max. | ||||||
Load variation influence *7 | 0.8% max. | 0.8% max. | ||||||
Temperature variation influence |
115 to 230 VAC input |
0.05%/°C max. | 0.05%/°C max. | |||||
Start up time *2 |
115 VAC input *6 |
530 ms typ. |
520 ms typ.. |
580 ms typ. |
550 ms typ. |
550 ms typ. |
600 ms typ. |
|
230 VAC input *6 |
330 ms typ. |
400 ms typ. |
400 ms typ. |
430 ms typ. |
490 ms typ. |
480 ms typ. |
||
Hold time *2 |
115 VAC input *6 |
28 ms typ. | 29 ms typ. | 32 ms typ. | 33 ms typ. | 36 ms typ. | 23 ms typ. | |
230 VAC input *6 |
134 ms typ. |
138 ms typ. |
134 ms typ. |
177 ms typ. |
170 ms typ. |
154 ms typ. |
||
Additional functions |
Overload protection | Yes, automatic reset | Yes, automatic reset | |||||
Overvoltage protection *5 | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||||
Series operation | Yes (For up to two Power Supplies, external diodes are required.) | |||||||
Parallel operation | Yes (Refer to Safety Precautions) (For up to two Power Supplies) | |||||||
Output indicator | Yes (LED: Green), lighting from 80% to 90% or more of rated voltage | |||||||
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 20 mA |
||||||
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA |
||||||||
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA |
||||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||||
Environment | Ambient operating temperature *12 |
-40 to 70°C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing) |
||||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||||
Ambient operating humidity | 0% to 95% (Storage humidity: 0% to 95%) | |||||||
Vibration resistance | 10 to 55 Hz, 0.375 mm half amplitude for 2 h each in X, Y, and Z directions | |||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions | |||||||
Reliability | MTBF | 135,000 hrs min. | ||||||
Life expectancy *9 | 10 years min. | |||||||
Construction | Weight | 150 g max. | 195 g max. | |||||
Cooling fan | No | |||||||
Degree of protection | IP20 by EN/IEC 60529 | |||||||
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 | ||||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | ||||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | |||||||
EMS | Conforms to EN 61204-3 high severity levels | |||||||
Approved Standards | UL Listed: UL 508 (Listing, Class2 Output: Per UL 1310) UL UR: UL 62368-1 (Recognition) cUL: CSA C22.2 No.107.1 (Class2 Output: Per CSA C22.2 No.223) cUR:CSA C22.2 No.62368-1 EN/VDE: EN 50178, EN 62368-1 |
|||||||
Conformed Standards | PELV (EN 60204-1, EN 50178) | |||||||
EN 61558-2-16 | ||||||||
EAC (TR CU 004 / 2011, TR CU 020 / 2011) | ||||||||
RCM (EN61000-6-4) | ||||||||
Marine Standards | Lloyd’s register *10 *11 | |||||||
SEMI | Conforms to F47-0706 ( 200 to 240 VAC input) |
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on Catalog for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. A characteristic when the ambient operating temperature is between –25 to 70°C.
*5. Refer to Overvoltage Protection on page 10 for the time when input voltage shuts off and input turns on again.
*6. The value is when both rated output voltage and rated output current are satisfied.
*7. 100 to 240 VAC input, in the range of 0 A to the rated output current.
*8. This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current.
*9. Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 21 for details.
*10. Safety Standards for a DC Input
The following safety standards apply to a DC input: UL 62368-1, cUR (CSA C22.2 No. 62368-1), EN 50178, EN 62368-1, and Lloyd’s.
For a DC input, safety is ensured by an external fuse.
Select an external fuse that meets the following conditions.
S8VK-G015[][]: 350 VDC min, 3 A
S8VK-G030[][]: 350 VDC min, 4 A
*11. Clamp filter “ZCAT2035-0930” manufactured by TDK Corporation. or equivalent should be installed in the cable connected to the input – output terminals of S8VK-G series.
Noise filter “FN2080-10-06” manufactured by SCHAFFNER Corporation. or equivalent should be connected to the Input terminals of S8VK-G series.
*12. At −40 to −25°C, time will be required before the rated output voltage is output after the input voltage is input. Also, the ripple noise value may exceed the value shown in the above table.
Power rating | 60 W | 120 W | |||
---|---|---|---|---|---|
Output voltage (VDC) | 12 V | 24 V | 24 V | ||
Efficiency | 230 VAC input *6 |
85% typ. | 88% typ. | 89% typ. | |
Input | Voltage range *1 | Single-phase, 85 to 264 VAC, 90 to 350 VDC *10 | |||
Frequency *1 | 50/60 Hz (47 to 450 Hz) | ||||
Current | 115 VAC input *6 |
1.0 A typ. | 1.1 A typ. | 1.3 A typ. | |
230 VAC input *6 |
0.6 A typ. | 0.7 A typ. | 0.7 A typ. | ||
Power factor | 230 VAC input, 100% load |
0.46 min. | 0.45 min. | 0.94 min. | |
Leakage current |
115 VAC input | 0.16 mA typ. | 0.24 mA typ. | ||
230 VAC input | 0.30 mA typ. | 0.38 mA typ. | |||
Inrush current *2 (for a cold start at 25°C) |
115 VAC input | 16 A typ. | 16 A typ. | ||
230 VAC input | 32 A typ. | 32 A typ. | |||
Output | Rated output current | 4.5 A | 2.5 A | 5 A | |
Boost current | 5.4 A | 0.125 | 6 A | ||
Voltage adjustment range *3 | -10% to 15% (with V.ADJ) (guaranteed) | ||||
Ripple & Noise voltage *4 |
100 to 240 VAC input, 100% load *6 |
150 mVp-p max. at 20 MHz of bandwidth |
50 mVp-p max. at 20 MHz of bandwidth |
150 mVp-p max. at 20 MHz of bandwidth |
|
Input variation influence *8 | 0.4% max. | 0.4% max. | |||
Load variation influence *7 | 0.8% max. | 0.8% max. | |||
Temperature variation influence |
115 to 230 VAC input |
0.05%/°C max. | 0.05%/°C max. | ||
Start up time *2 |
115 VAC input *6 |
570 ms typ. | 650 ms typ. | 790 ms typ. | |
230 VAC input *6 |
430 ms typ. | 500 ms typ. | 750 ms typ. | ||
Hold time *2 |
115 VAC input *6 |
26 ms typ. | 25 ms typ. | 42 ms typ. | |
230 VAC input *6 |
139 ms typ. | 129 ms typ. | 42 ms typ. | ||
Additional functions |
Overload protection | Yes, automatic reset | Yes, automatic reset | ||
Overvoltage protection *5 | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||
Series operation | Yes (For up to two Power Supplies, external diodes are required.) | ||||
Parallel operation | Yes (Refer to Safety Precautions) (For up to two Power Supplies) | ||||
Output indicator | Yes (LED: Green), lighting from 80% to 90% or more of rated voltage | ||||
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 20 mA |
|||
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA |
|||||
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA |
|||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
||||
Environ- ment |
Ambient operating temperature *12 |
-40 to 70°C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing) |
|||
Storage temperature | -40 to 85°C (with no condensation or icing) | ||||
Ambient operating humidity | 0% to 95% (Storage humidity: 0% to 95%) | ||||
Vibration resistance | 10 to 55 Hz, 0.375 mm half amplitude for 2 h each in X, Y, and Z directions |
||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions | ||||
Reliability | MTBF | 135,000 hrs min. | |||
Life expectancy *9 | 10 years min. | ||||
Con- struction |
Weight | 260 g max. | 620 g max. | ||
Cooling fan | No | ||||
Degree of protection | IP20 by EN/IEC 60529 | ||||
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 | |||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | |||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | ||||
EMS | Conforms to EN 61204-3 high severity levels | ||||
Approved Standards | UL Listed: UL 508 (Listing, For 60 W only Class2 Output: Per UL 1310 ) UL UR: UL 62368-1 (Recognition) cUL: CSA C22.2 No.107.1 (For 60 W only Class2 Output: Per CSA C22.2 No.223) cUR: CSA C22.2 No.62368-1 EN/VDE: EN 50178, EN 62368-1 |
||||
Conformed Standards | PELV (EN 60204-1, EN 50178) | ||||
EN 61558-2-16 | |||||
EAC (TR CU 004 / 2011, TR CU 020 / 2011) | |||||
RCM (EN61000-6-4) | |||||
Marine Standards | Lloyd’s register *10 *11 | ||||
SEMI | Conforms to F47-0706 (200 to 240 VAC input) |
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on Catalog for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. A characteristic when the ambient operating temperature is between –25 to 70°C.
*5. Refer to Overvoltage Protection on page 10 for the time when input voltage shuts off and input turns on again.
*6. The value is when both rated output voltage and rated output current are satisfied.
*7. 100 to 240 VAC input, in the range of 0 A to the rated output current.
*8. This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current.
*9. Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 21 for details.
*10. Safety Standards for a DC Input
The following safety standards apply to a DC input: UL 62368-1, cUR (CSA C22.2 No. 62368-1), EN 50178, EN 62368-1, and Lloyd’s.
For a DC input, safety is ensured by an external fuse.
Select an external fuse that meets the following conditions.
S8VK-G015[][]: 350 VDC min, 3 A
S8VK-G030[][]: 350 VDC min, 4 A
*11. Clamp filter “ZCAT2035-0930” manufactured by TDK Corporation. or equivalent should be installed in the cable connected to the input – output terminals of S8VK-G series.
Noise filter “FN2080-10-06” manufactured by SCHAFFNER Corporation. or equivalent should be connected to the Input terminals of S8VK-G series.
*12. At −40 to −25°C, time will be required before the rated output voltage is output after the input voltage is input. Also, the ripple noise value may exceed the value shown in the above table.
Power rating | 240 W | 480 W | ||||
---|---|---|---|---|---|---|
Output voltage (VDC) | 24 V | 48 V | 24 V | 48 V | ||
Efficiency | 230 VAC input *6 |
92% typ. | 93% typ. | |||
Input | Voltage range *1 | Single-phase, 85 to 264 VAC, 90 to 350 VDC *10 | ||||
Frequency *1 | 50/60 Hz (47 to 63 Hz) | |||||
Current | 115 VAC input *6 |
2.4 A typ. | 4.7 A typ. | |||
230 VAC input *6 |
1.3 A typ. | 2.3 A typ. | ||||
Power factor | 230 VAC input, 100% load |
0.9 min. | 0.97 min. | |||
Leakage current |
115 VAC input | 0.23 mA typ. | 0.3 mA typ. | |||
230 VAC input | 0.33 mA typ. | 0.49 mA typ. | ||||
Inrush current *2 (for a cold start at 25°C) |
115 VAC input | 16 A typ. | 16 A typ. | |||
230 VAC input | 32 A typ. | 32 A typ. | ||||
Output | Rated output current | 10 A | 5 A | 20 A | 10 A | |
Boost current | 12 A | 6 A | 24 A | 12 A | ||
Voltage adjustment range *3 | -10% to 15% (with V.ADJ) (guaranteed) | |||||
Ripple & Noise voltage *4 |
100 to 240 VAC input, 100% load *6 |
180 mVp-p max. at 20 MHz of bandwidth |
350 mVp-p max. at 20 MHz of bandwidth |
230 mVp-p max. at 20 MHz of bandwidth |
470 mVp-p max. at 20 MHz of bandwidth |
|
Input variation influence *8 | 0.4% max. | 0.4% max. | ||||
Load variation influence *7 | 0.8% max. | 0.8% max. | ||||
Temperature variation influence |
115 to 230 VAC input |
0.05%/°C max. | 0.05%/°C max. | |||
Start up time *2 |
115 VAC input *6 |
250 ms typ. | 290 ms typ. | 380 ms typ. | ||
230 VAC input *6 |
250 ms typ. | 290 ms typ. | 260 ms typ. | |||
Hold time *2 |
115 VAC input *6 |
44 ms typ. | 43 ms typ. | 40 ms typ. | ||
230 VAC input *6 |
44 ms typ. | 50 ms typ. | ||||
Additional functions |
Overload protection | Yes, automatic reset | Yes, automatic reset | |||
Overvoltage protection *5 | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||
Series operation | Yes (For up to two Power Supplies, external diodes are required.) | |||||
Parallel operation | Yes (Refer to Safety Precautions) (For up to two Power Supplies) | |||||
Output indicator | Yes (LED: Green), lighting from 80% to 90% or more of rated voltage | |||||
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 20 mA |
||||
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA |
||||||
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA |
||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||
Environ- ment |
Ambient operating temperature *12 |
-40 to 70 °C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing) |
||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||
Ambient operating humidity | 0% to 95% (Storage humidity: 0% to 95%) | |||||
Vibration resistance | 10 to 55 Hz, 0.375 mm half amplitude for 2 h each in X, Y, and Z directions |
|||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions | |||||
Reliability | MTBF | 135,000 hrs min. | ||||
Life expectancy *9 | 10 years min. | |||||
Con- struction |
Weight | 900 g max. | 1,500 g max. | |||
Cooling fan | No | |||||
Degree of protection | IP20 by EN/IEC 60529 | |||||
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 | ||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | ||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | |||||
EMS | Conforms to EN 61204-3 high severity levels | |||||
Approved Standards | UL Listed: UL 508 (Listing) UL UR: UL 62368-1 (Recognition) cUL: CSA C22.2 No.107.1 cUR: CSA C22.2 No.62368-1 EN/VDE: EN 50178, EN 62368-1 |
|||||
Conformed Standards | PELV (EN 60204-1, EN 50178) | |||||
EN 61558-2-16 | ||||||
EAC (TR CU 004 / 2011, TR CU 020 / 2011) | ||||||
RCM (EN61000-6-4) | ||||||
Marine Standards | Lloyd’s register *10 *11 | |||||
SEMI | Conforms to F47-0706 (200 to 240 VAC input) |
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on Catalog for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. A characteristic when the ambient operating temperature is between –25 to 70°C.
*5. Refer to Overvoltage Protection on page 10 for the time when input voltage shuts off and input turns on again.
*6. The value is when both rated output voltage and rated output current are satisfied.
*7. 100 to 240 VAC input, in the range of 0 A to the rated output current.
*8. This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current.
*9. Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 21 for details.
*10. Safety Standards for a DC Input
The following safety standards apply to a DC input: UL 62368-1, cUR (CSA C22.2 No. 62368-1), EN 50178, EN 62368-1, and Lloyd’s.
For a DC input, safety is ensured by an external fuse.
Select an external fuse that meets the following conditions.
S8VK-G015[][]: 350 VDC min, 3 A
S8VK-G030[][]: 350 VDC min, 4 A
*11. Clamp filter “ZCAT2035-0930” manufactured by TDK Corporation. or equivalent should be installed in the cable connected to the input – output terminals of S8VK-G series.
Noise filter “FN2080-10-06” manufactured by SCHAFFNER Corporation. or equivalent should be connected to the Input terminals of S8VK-G series.
*12. At −40 to −25°C, time will be required before the rated output voltage is output after the input voltage is input.
Also, the ripple noise value may exceed the value shown in the above table.
Dimensions | Power Supplies – S8VK-G
S8VK-G015[][] (15 W)
S8VK-G030[][] (30 W)
S8VK-G060[][] (60 W)
S8VK-G12024 (120 W)
S8VK-G240[][] (240 W)
S8VK-G480[][] (480 W))
DIN Rail (Order Separately)
Mounting Rail (Material: Aluminum)
PFP-100N
PFP-50N
Mounting Rail (Material: Aluminum)
PFP-100N2
End Plate
PFP-M
Note: If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from aluminum abrasion.
Mounting Brackets
Features | Power Supplies – S8VK-G
Superior Basic Performance That Ensures Reliability.
Wide Range of Standards Certification and Greater Usability.
Propesties | Power Supplies – S8VK-G
Power Supplies | S8VK-G | |
---|---|---|
Power rating | 15 – 600 W | |
Output | 5 – 48 V | |
Input | Single-phase, 85 to 264 VAC, 90 to 350 VDC , 265 to 300 VAC | |
Frequency | 50 – 60 Hz | |
Power factor | 0.9 | |
Rated output current | 0.65 – 50 A | |
Dimensions (W x L x D) mm |
15 – 30 W | 36.2 x 82 x 117.7 |
50 W | 37.2 x 97 x 117.7 | |
100 W | 38 x 97 x 129 | |
150 W | 38 x 97 x 159 | |
300 W | 41 x 102 x 170 | |
150 W | 61 x 120 x 190 | |
Weight | 250g – 1,050g |