OMRON Proximity Sensor - E2NC
OMRON Proximity Sensor Separate Amplifier – E2NC
Model Numbers | Proximity Sensor Separate Amplifier – E2NC
Sensors
Sensor Heads
Type | Appearance | Sensing Distances |
Repeat accuracy |
Cable specification | Model | |
---|---|---|---|---|---|---|
Shielded | Cylindrical |
3 dia. × 18 mm | 0.6 mm | 1 μm | Free cutting *2 | E2NC-EDR6-F |
5.4 dia. × 18 mm | 1 mm | 1 μm | Standard *2 | E2NC-ED01 | ||
Free cutting *2 | E2NC-ED01-F | |||||
With Protective Spiral Tube *1*2 |
E2NC-ED01-S | |||||
8 dia. × 22 mm | 2 mm | 2 μm | Standard *2 | E2NC-ED02 | ||
Free cutting *2 | E2NC-ED02-F | |||||
With Protective Spiral Tube *1*2 |
E2NC-ED02-S | |||||
Screw |
M10 × 22 mm | 2 mm | 2 μm | Standard *2 | E2NC-EM02 | |
Free cutting *2 | E2NC-EM02-F | |||||
With Protective Spiral Tube *1*2 |
E2NC-EM02-S | |||||
Flat |
30 × 14 × 4.8 mm | 5 mm | 2 μm | Standard *2 | E2NC-EV05 | |
Free cutting *2 | E2NC-EV05-F | |||||
With Protective Spiral Tube *1*2 |
E2NC-EV05-S | |||||
Unshielded | Screw |
M18 × 46.3 mm | 7 mm | 5 μm | Standard *2 | E2NC-EM07M |
Free cutting *2 | E2NC-EM07M-F | |||||
With Protective Spiral Tube *1*2 |
E2NC-EM07M-S | |||||
Heat- resistant |
Screw |
M12 × 22 mm | 2 mm | 2 μm | Standard *2 | E2NC-EM02H |
*1. Ask your OMRON representative for information on the Protective Spiral Tube.
*2. Standard models and models with Protective Spiral Tube: The standard cable length is 2.6 m, Free-cut models: The
standard cable length is 3.6 m. (Standard cable length is the length containing the preamplifier and connector.)
Amplifier Units
Type | Appearance | Connection method | Input/output | Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Advanced models | Pre-wired (2 m) | 2 outputs + 1 input | E2NC-EA21 2M | E2NC-EA51 2M | |
Wire-saving Connectors | 2 outputs | E2NC-EA7TW | E2NC-EA9TW | ||
Wire-saving Connectors | 1 output + 1 input | E2NC-EA7 | E2NC-EA9 | ||
Model for Sensor Communications Unit * |
Connector for Sensor Communications Unit |
— | E2NC-EA0 | ||
Connector for Sensor Communications Unit Pre-wired (2 m) |
1 output | E2NC-EA10 2M | E2NC-EA40 2M |
* A Sensor Communications Unit is required if you want to use the Amplifier Unit on a network.
Accessories (Sold Separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
*Protective stickers are provided.
Type | Appearance | Cable length | No. of conductors | Model | Applicable Amplifier Units |
---|---|---|---|---|---|
Master Connector | 2 m | 4 | E3X-CN21 | E2NC-EA7TW E2NC-EA9TW E2NC-EA7 E2NC-EA9 |
|
Slave Connector | 2 | E3X-CN22 |
End Plate
Two End Plates (PFP-M) are provided with the Sensor Communications Unit.
End Plates (PFP-M and E39-EP1) are not provided with the Amplifier Unit. They must be ordered separately as required.
Appearance | Model | Quantity | Applicable Amplifier Units |
---|---|---|---|
PFP-M | 1 | E2NC-EA21 E2NC-EA51 E2NC-EA7[][] E2NC-EA9[][] E2NC-EA0 |
|
E39-EP1 | 1 | E2NC-EA10 E2NC-EA40 |
Related Products
Sensor Communications Units
Type | Appearance | Model |
---|---|---|
Sensor Communications Unit for EtherCAT | E3NW-ECT | |
Sensor Communications Unit for CC-Link | E3NW-CCL | |
Distributed Sensor Unit * | E3NW-DS |
Refer to your OMRON website for details.
* The Distributed Sensor Unit can be connected to any of the Sensor Communications Units.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association.
Specifications | Proximity Sensor Separate Amplifier – E2NC
Sensor Heads
Model | E2NC-EDR6-F | E2NC-ED01(-[]) | E2NC-ED02(-[]) | E2NC-EM02(-[]) | |
---|---|---|---|---|---|
3 dia. × 18 mm | 5.4 dia. × 18 mm | 8 dia. × 22 mm | M10 × 22 mm | ||
Sensing Distances | 0.6 mm | 1 mm | 2 mm | 2 mm | |
Sensing object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | 5 × 5 mm | 5 × 5 mm | 10 × 10 mm | 10 × 10 mm | |
Material: iron (t = 3, S50C) | |||||
Repeatability *1 | 1 μm | 1 μm | 2 μm | 2 μm | |
Hysteresis distance | Variable | ||||
Temperature characteristics *2 |
Sensor Head | 0.3%/°C | 0.08%/°C | 0.08%/°C | 0.08%/°C |
Preamplifier and Amplifier |
0.08%/°C | ||||
Ambient temperature range *3 |
Operating | -10°C to 60°C (with no icing or condensation) | |||
Storage | -10°C to 60°C (with no icing or condensation) |
-20°C to 70°C (with no icing or condensation) | |||
Ambient humidity | Operating/storage: 35% to 85% (with no condensation) | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case | ||||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||||
Degree of protection (Sensor Head) |
IEC60529 IP67 | ||||
Weight (packed state) *6 | Approx. 120 g | ||||
Materials | Sensor Head | Brass | SUS | Brass | Brass |
Sensing surface | Heat-resistant ABS | ||||
Clamping nut | — | Nickel-plated brass |
|||
Toothed washer | — | Zinc-plated iron | |||
Preamplifier | PES | ||||
Connection method *7 | Connector (Standard models and models with Protective Spiral Tube: The standard cable length is 2.6 m, Free-cut models: The standard cable length is 3.6 m.) |
||||
Accessories | Instruction Manual, Mounting Brackets |
Model | E2NC-EV05(-[]) | E2NC-EM07M(-[]) | E2NC-EM02H | |
---|---|---|---|---|
30 × 14 × 4.8 mm | M18 × 46.3 mm | M12 × 22 mm | ||
Sensing Distances | 5 mm | 7 mm | 2 mm | |
Sensing object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
|||
Standard sensing object | 15 × 15 mm | 22 × 22 mm | 20 × 20 mm | |
Material: iron (t = 3, S50C) | ||||
Repeatability *1 | 2 μm | 5 μm | 2 μm | |
Hysteresis distance | Variable | |||
Temperature characteristics *2 |
Sensor Head | 0.04%/°C | 0.08%/°C | 0.2%/°C |
Preamplifier and Amplifier |
0.08%/°C | |||
Ambient temperature range *3 |
Operating | -10°C to 60°C (with no icing or condensation) | -10°C to 200°C (with no icing or condensation) *4 |
|
Storage | -20°C to 70°C (with no icing or condensation) | |||
Ambient humidity | Operating/storage: 35% to 85% (with no condensation) | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case | |||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||
Degree of protection (Sensor Head) |
IEC60529 IP67 | IEC60529 IP60 *5 | ||
Weight (packed state) *6 | Approx. 120 g | |||
Materials | Sensor Head | Zinc | Brass | Brass |
Sensing surface | Heat-resistant ABS | PEEK | ||
Clamping nut | — | Nickel-plated brass | ||
Toothed washer | — | Zinc-plated iron | ||
Preamplifier | PES | PEEK | ||
Connection method *7 | Connector (Standard models and models with Protective Spiral Tube: The standard cable length is 2.6 m, Free-cut models: The standard cable length is 3.6 m.) |
|||
Accessories | Instruction Manual, Mounting Brackets |
*1. Repeatability: The standard reference object at 1/2 of the measurement range.
*2. Temperature characteristic: The standard reference object at 1/2 of the measurement range.
*3. Do not expose the product to rapid temperature changes, otherwise the characteristics may be deteriorated.
*4. Sensor Head only (The ambient temperature of other parts is -10 to 60°C)
*5. Do not expose the product to steam. This product does not have any protection mean against water.
*6. The protective spiral tube adds another 90 g to the weight.
*7. Standard length is the length containing the preamplifier and connector.
Amplifier Unit
Types | Advanced models | Model for Sensor Communications Unit *1 |
||||
---|---|---|---|---|---|---|
NPN output | E2NC-EA21 | E2NC-EA7TW | E2NC-EA7 | E2NC-EA10 | E2NC-EA0 | |
PNP output | E2NC-EA51 | E2NC-EA9TW | E2NC-EA9 | E2NC-EA40 | ||
Connecting method | Pre-wired (2 m) |
Wire-saving Connectors | Connector for Sensor Com- munications Unit Pre- wired (2 m) |
Connector for Sensor Com- munications Unit |
||
Input/ output |
Output | 2 outputs | 1 output | 1 output *2 | 2 outputs *3 | |
External inputs *4 |
1 input | — | 1 input | — | — | |
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | Refer to the communication unit specifications. |
||||
Power consumption *5 | At Power Supply Voltage of 24 VDC Normal mode: 1,080 mW max. (Current consumption at 45 mA max.), Eco function ON: 840 mW max. (Current consumption at 35 mA max.), Eco function LO: 960 mW max. (Current consumption at 40 mA max.) |
|||||
Control output | Load power supply voltage: 30 VDC max., open collector output Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max. |
Refer to the communication unit specifications. |
||||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), NO/NC indicator (orange), ST indicator (blue) and OUT selection indicator (orange, only on models with 2 outputs) |
|||||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection | Power supply reverse polarity protection, output short-circuit protection |
||||
Response time |
Super-high- speed mode (SHS) |
Operate or reset: 150 μs | ||||
High-speed mode (HS) |
Operate or reset: 300 μs (default setting) | |||||
Standard mode (Stnd) |
Operate or reset: 1 ms | |||||
GIGA power mode (GIGA) |
Operate or reset: 4 ms | |||||
Sensitivity adjustment | Smart Tuning (Fine Positioning, 2-point Tuning, Position Tuning, Percentage Tuning (-99% to 99%), Full Auto Tuning, or manual adjustment |
|||||
Maximum connectable Units |
16 units | With E3NW-ECT: 30 units *6 With E3NW-CCL: 16 units |
||||
No. of Units for mutual interference prevention |
Up to five units, intermittent oscillation method (response time = (No. of connected units + 1) x 15 ms) Note: The mutual interference prevention function is disabled if Super High Speed mode (SHS) is selected for detection function. |
|||||
Functions | Operation mode |
NO (Normally Open)/NC (Normally closed) | ||||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms |
|||||
Differential detection |
Single edge: Can be set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms. | |||||
Zero reset | Provided Zero-reset is accompanied by a change of detection distance. After zero-reset, some threshold level may also cause a change of the indication by influence of other settings. |
|||||
Resetting settings *7 |
Select from initial reset (factory defaults) or user reset (saved settings). | |||||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). |
|||||
Bank switching |
Select from banks 1 to 4. | |||||
Output 1 | Select from normal detection mode, area detection mode or differential detection mode. | |||||
Output 2 | Select from normal detection mode, alarm output mode, error output mode or disconnection detection output mode. |
— | — | Select from normal detection mode, alarm output mode, error output mode or disconnection detection output mode. |
||
External input |
Select from input OFF, 2-point Tuning, Percent- age Tuning, Full Auto Tuning, Fine Positioning, zero reset, synchronization detection, or bank switching. |
— | Select from input OFF, 2-point Tuning, Percent- age Tuning, Full Auto Tuning, Fine Positioning, zero reset, synchronization detection, or bank switching. |
— | — | |
Hysteresis width |
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. |
|||||
Changing the displays |
Threshold/Detected intensity ratio, Peak receiving Detected amount/Bottom Detected amount, Threshold bar display, Peak Detected amount/ Receiving Detected and CH number/Detected amount |
Threshold/ Detected intensity ratio, Peak receiving Detected amount/ Bottom Detected amount, Threshold bar display, Peak Detected amount/ Receiving Detected and CH number/ Detected amount |
||||
Ambient temperature range |
Operating: Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above |
|||||
Altitude | 2,000 m max. | |||||
Installation environment | Pollution degree 3 | |||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance (destruction) |
500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each in X, Y, and Z directions |
||||
Weight (packed state/ Sensor only) |
Approx. 115 g/ Approx. 75 g |
Approx. 60 g/ Approx. 20 g |
Approx. 60 g/ Approx. 20 g |
Approx. 95 g/ Approx. 45 g |
Approx. 65 g/ Approx. 25 g |
|
Materials | Case | Polycarbonate (PC) | ||||
Cover | Polycarbonate (PC) | |||||
Cable | PVC | |||||
Accessories | Instruction Manual |
*1. The communication unit is compatible with EtherCAT type E3NW-ECT and E3NW-CCL of CC-Link. This unit is not usable
with E3NW-CRT.
*2. Channel 1 of each amplifier unit is output as the output drawn by the cord.
*3. Output signals from two sensors are assigned to the PLC via the network.
Various settings can be changed and detected values can be read by operating the PLC via the network.
*4. The following details apply to the input.
Contact input (relay or switch) | Non-contact input (transistor) | Input time *4-1 |
|
---|---|---|---|
NPN output E2NC-EA21 E2NC-EA7 |
ON: Shorted to 0 V (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (Sourcing current: 1 mA max.) OFF: Vcc – 1.5 V to Vcc (Leakage current: 0.1 mA max.) |
ON: 9 ms min. OFF: 20 ms min. |
PNP output E2NC-EA51 E2NC-EA9 |
ON: Shorted to Vcc (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V. |
ON: Vcc – 1.5 V to Vcc (Sinking current: 3 mA max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.) |
*4-1. Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
*5. At Power supply voltage of 10 to 30 VDC
Normal mode: 1,110 mW max. (Current consumption: 37 mA max. at 30 VDC, 76 mA max. at 10 VDC)
Eco function ON: 900 mW max. (Current consumption: 30 mA max. at 30 VDC, 48 mA max. at 10 VDC)
Eco function LO: 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 58 mA max. at 10 VDC)
*6. When connected to an OMRON NJ-series Controller. For details, refer to the communication unit manual.
*7. The bank is not reset by the user reset function or saved by the user save function.
Dimensions | Proximity Sensor Separate Amplifier – E2NC
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensor Heads
E2NC-EDR6-F
E2NC-ED01(-F)
E2NC-ED01-S
E2NC-ED02(-F)
E2NC-ED02-S
E2NC-EM02(-F)
E2NC-EM02-S
E2NC-EM07M(-F)
E2NC-EM07M-S
E2NC-EV05(-F)
E2NC-EV05-S
E2NC-EM02H
Amplifier Unit
Pre-wired Amplifier Units
E2NC-EA21
E2NC-EA51
Amplifier Units with Wire-saving Connectors
E2NC-EA7TW
E2NC-EA9TW
E2NC-EA7
E2NC-EA9
Amplifier Unit with Connector for Sensor Communications Unit
E2NC-EA0
Amplifier Unit with Connector for Sensor Communications Unit (Pre-wired)
E2NC-EA10
E2NC-EA40
Accessories (Sold Separately)
Wire-saving Connectors
Master Connector
E3X-CN21
Slave Connector
E3X-CN22
Mounting Bracket
E39-L143
End Plate
PFP-M
E39-EP1
คุณสมบัติ | Proximity Sensor Separate Amplifier – E2NC
- หัวเซนเซอร์ที่หลากหลายให้เลือกตามการใช้งาน สายแบบยืดหยุ่นที่ไว้ใช้ระหว่าง พรีแอมพลิฟายเออร์ และแอมพลิฟายเออร์ของหัวเซนเซอร์
- ทนต่อการเปลี่ยนแปลงของอุณหภูมิโดยรอบได้สูง ลักษณะอุณหภูมิ 0.08% / °C
- ทำการตั้งค่าการตรวจจับที่ง่ายและเชื่อถือได้ด้วยความแม่นยำระดับไมครอนโดยใช้ฟังก์ชันทีชชิ่ง
- ตรวจสอบประดับการรับรู้ส่วนเกินบนจอแสดงผลดิจิตอล
- รองรับการกำหนดตำแหน่งและการคัดกรองที่มีความแม่นยำสูงพร้อมการกำหนดตำแหน่งที่ดีเพื่อเพิ่มรูปแบบต่างๆ
- รุ่นสำหรับรองรับหน่วยสื่อสารเซนเซอร์ EtherCAT หน่วยสื่อสารเซนเซอร์ หรือ CC-Link หน่วยสื่อสารเซนเซอร์
คุณสมบัติ | Proximity Sensor Separate Amplifier – E2NC
Proximity Sensor Separate Amplifier | E2NC | |
---|---|---|
หัวเซนเซอร์ | ระยะตรวจจับ | 0.6, 1, 2, 5, 7 mm |
การตรวจจับ | วัตถุโลหะกลุ่มเหล็ก | |
ระดับการป้องกัน | IP67 | |
วัสดุ | ทองเหลือง SUS | |
แอมพลิฟายเออร์ | แรงดันไฟฟ้า | 10 – 30 VDC |
การใช้พลังงาน | โหมดปกติ สูงสุด 1,080 มิลลิวัตต์ | |
เวลาตอบสนอง | โหมดมาตรฐาย 1 มิลลิวินาที | |
วัสดุตัวเรือน | โพลีคาร์บอเนต (PC) |