OMRON Timer - H3DT-H
Model Numbers | Timer – H3DT-H
List of Models
Operating modes | Supply voltage | Control output | H3DT-H | ||
---|---|---|---|---|---|
S Series (time range: 0.1 to 12 s) |
L Series (time range: 1.0 to 120 s) |
||||
Power OFF Delay | 100 to 120 VAC | Contact output: SPDT | Model | H3DT-HCS | H3DT-HCL |
200 to 240 VAC | Contact output: SPDT | H3DT-HDS | H3DT-HDL | ||
24 to 48 VAC/DC | Contact output: SPDT | H3DT-HBS | H3DT-HBL |
Model Structure
Model | Terminal block | Operating/resetting method | Output type | Mounting method | Safety standards |
---|---|---|---|---|---|
H3DT-H | 6 terminals | Instantaneous operation / time-limit reset | Relay, SPDT | DIN Track mounting | cULus (UL 508 CSA C22.2 No. 14) CCC LR DNV GL EN 61812-1 IEC 60664-1 4 kV/2 |
Specifications | Timer – H3DT-H
Time Ranges
S Series | L Series | |||
---|---|---|---|---|
Time range setting | x0.1 | x1 | x1 | x10 |
Set time range | 0.1 to 1.2 s | 1 to 12 s | 1 to 12 s | 10 to 120 s |
Power ON time | 0.1 s min. | 0.3 s min. | ||
Scale numbers | 12 |
Ratings
Supply voltage | H3DT-HCS/-HCL | 100 to 120 VAC, 50/60 Hz |
---|---|---|
H3DT-HDS/-HDL | 200 to 240 VAC, 50/60 Hz | |
H3DT-HBS/-HBL | 24 to 48 VAC/DC, 50/60 Hz *1 | |
Allowable voltage fluctuation range | 85% to 110% of rated voltage | |
Power consumption | H3DT-HCS | At 120 VAC: 8.7 VA max. |
H3DT-HCL | At 120 VAC: 8.8 VA max. | |
H3DT-HDS | At 240 VAC: 21.6 VA max. | |
H3DT-HDL | At 240 VAC: 21.7 VA max. | |
H3DT-HBS/-HBL | At 48 VAC: 1.0 VA max., at 24 VDC: 0.4 W max. | |
Timer operation starting voltage | 30% or less of power supply voltage | |
Rated Insulation Voltage | 250 VAC | |
Control output | Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC with resistive load Contact materials: Ag-alloy (Recommended fuse: BLN5 (Littelfuse) or 0216005MXEP) |
|
Ambient operating temperature | -20 to 60°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Surrounding air operating humidity | 25% to 85% |
* DC ripple: 20% max.
Characteristics
Accuracy of operating time | ±1% of FS max. (±1% ±10 ms max. at 1.2-s range) | |
---|---|---|
Setting error | ±10% of FS ±0.05 s max. | |
Influence of voltage | ±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range) | |
Influence of temperature | ±2% of FS max. (±2% ±10 ms max. at 1.2-s range) | |
Insulation resistance | 100 MΩ min. at 500 VDC | |
Dielectric strength | Between charged metal part and operating section: 2,900 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
Impulse withstand test voltage |
Between power supply terminals: 1 kV for 24-VAC/DC and 48-VAC/DC models, 5 kV for all other models. Between conductor terminal and operating section: 7.4 kV |
|
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise): ±1.5 kV (between power supply terminals) |
|
Static immunity | Malfunction: 4 kV, Destruction: 8 kV | |
Vibration resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
Shock resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions |
Malfunction | 100 m/s2 3 times each in 6 directions | |
Life expectancy |
Mechanical | 10 million operations min. (under no load at 1,800 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | |
Degree of protection | IP30 (Terminal block: IP20) | |
Weight | Approx. 90 g |
Relation between H3DT Ambient Temperature and Mounting Interval (Reference Values)
The relation between the ambient temperature and mounting interval is shown in the following graph.
If the Timer is used at 55°C or higher with a mounting interval that is smaller than that shown in the following diagram, the temperature inside the Timer will increase, reducing the life expectancy of internal parts.
Applicable standards
Safety standards | cULus: UL 508/CSA C22.2 No. 14 EN 61812-1: Pollution degree 2, Overvoltage category III CCC: GB/T 14048.5 Pollution degree 2, Overvoltage category III * LR: Category ENV1.2 DNV GL (Temperature B, Humidity B, Vibration A, EMC A, Enclosure A) |
---|---|
EMC | (EMI) EN 61812-1 Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN 61000-3-3 (EMS) EN 61812-1 Immunity ESD: EN 61000-4-2 Immunity RF-interference: EN 61000-4-3 Immunity Burst: EN 61000-4-4 Immunity Surge: EN 61000-4-5 Immunity Conducted Disturbance: EN 61000-4-6 Immunity Voltage Dip/Interruption: EN 61000-4-11 |
* CCC certification requirements
Rated operating voltage Ue Rated operating current Ie |
AC-15: Ue: 250 VAC, Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 0.1 A |
---|---|
Rated impulse withstand voltage (altitude: 2,000 m max.) |
4 kV (at 240 VAC) |
Conditional short-circuit current | 1,000 A |
I/O
Input | None | |
---|---|---|
Output | Control output | The Timer operates as soon as the Timer is turned ON. The Timer starts timing when the power is turned OFF and the output is turned OFF when the time set on the dial elapses. |
Dimensions | Timer – H3DT-H
Timers
H3DT-H
Track Mounting Products (Sold Separately)
DIN Track
PFP-100N
PFP-50N
DIN Track
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Note: 1. Order the above products in multiples of 10.
2. The Tracks conform to DIN standards.
Options (Order Separately)
Front Cover
Y92A-D1A
Features | Timer – H3DT-H
- Set two-time with each Timer.
- Reduces power consumption (active power) by up to 60% to help reduce heat generation in control panels
- Slim timers (17.5-mm width) with two sets of contacts: One of the slimmest timers worldwide
- RoHS compliant
Properties | Timer – H3DT-H
Timer | H3DT-H |
---|---|
Power supply | 24 – 240 Vac/Vdc (50 – 60 Hz) |
Input | 24 – 240 Vac/Vdc (50 – 60 Hz) |
Reset system | Power reset (10% rated of voltage) |
Output | Relay (250 Vac / 30 Vdc 5A) |
Size (W x L x D) (mm) | 17.5 x 100 x 90 |
Weight (g) | 90 |