ตัวกรองชีฟบาสเก็ต (Rexroth Replacement cartridge filter)
Suction and Replacement Cartridge Filters รุ่น 7 SLS.
รายละเอียด Rexroth Suction and Replacement Cartridge Filters.
- Size 90 … 260
- Max. operating pressure 7 bar
- Flow, max. 190 l/min
- Port G1 1/4, G1 ½
Features
- Filters for inline installation
- Special highly efficient filter media
- Filtration of very fine particles and high dirt holding capacity across a broad pressure differential range
- Optionale Ausführung mit Wartungsanzeige, Manometer od
- er Vakuummeter
- Installation in suction, pressure and return lines possible
- Optimiert für Mobilhydraulik, platzsparend und servicefreundlich
- 7 SLS version with return flow block, patented and environmentally friendly
Optional bypass valve integrated in the filter housing
Type Code
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7SLS. | – | S | – | 0 | – | 0 |
Series | |||
---|---|---|---|
01 | Suction and pressure inline filter with isolator valve, 7 bar | 7SLS | |
Size | |||
02 | 90 | ||
130 | |||
180 1) | |||
260 2) | |||
Filter rating in μm | |||
03 | Nominal | Paper, not cleanable | P5 |
P10 | |||
P25 | |||
Non-woven glass fiber media, not cleanable | Absolute (ISO 16889) | H1XL | |
H3XL | |||
H6XL | |||
H10XL | |||
H20XL | |||
Pressure differential | |||
04 | max. admissible pressure differential of the filter element 5 bar | S | |
Element design | |||
05 | Standard adhesive T = 100 °C | 0… | |
Special adhesive T = 170 °C | H… | ||
Standard material | 0 | ||
Solenoid | |||
06 | without | 0 | |
Bypass valve | |||
07 | without | 0 | |
0.3 bar | 1 | ||
0.8 bar | 2 | ||
1.5 bar | 3 | ||
2.0 bar | 4 | ||
2.5 bar | 5 | ||
3.0 bar | 6 | ||
Maintenance indicator | |||
08 | without | 0 | |
Pressure gauge 0…6 bar | A | ||
Vacuum meter -1…0.6 bar | C | ||
Vacuum switch normally open contact | F0,2 | ||
Vacuum switch normally closed contact | G0,2 | ||
Pressure switch normally open contact | H1,5 | ||
Pressure switch normally closed contact | J1,5 | ||
Port | |||
09 | Pipe thread | R0 | |
SAE flange | S0 | ||
UNF thread | U0 | ||
Seal | |||
10 | NBR | M | |
FKM | V | ||
Material | |||
11 | Standard material | 0 | |
Supplementary information | |||
12 | without | 0 | |
Check valve in outlet only with “0” without bypass valve | R | ||
Certificate | Z |
Model | Code |
---|---|
7 SLS 130 P10-S00-0B0,4G0-SP000616-0/RH& | R928048616 |
7 SLS 180 H10XL-S00-01F0,2-R0M00 | R928053277 |
7 SLS 90 P25-S00-000-R0M00 | R928040658 |
7 SLS 90 P25-S00-00A-R0M0R | R928038892 |
7 SLS 90 P25-S00-040-R0M00 | R928052023 |